文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,438+ SCI 论文 与阿拉丁产品引用相关
2,295,919.25 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

1 项目

设置提升方向
三癸胺
MEASUREMENT SCIENCE and TECHNOLOGY · 2016 ·Vol. 27 ·期 10 ·105101 · IF 1.492

A solid-contact pH-selective electrode based on tridodecylamine as hydrogen neutral ionophore

Jianxin Zhang,Yixuan Guo,Shangjin Li,Hui Xu

The solid-state pH electrode has the potential possibility to be used in many extreme situations with satisfactory accuracy and low cost. But its performance is affected by the solid electrolyte, preparation process, and the structure of the sensitive membrane, etc. In this work, the relationships between these factors and the characteristic of the prepared electrode were verified by controlling the preparation conditions with a variety of electrochemical methods. Firstly, the solid electrolyte poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) was electrochemically deposited on the screen-printed carbon electrode (SPCE) substrate by a potentiostatic method in an aqueous solution containing 0.01 M 3,4-ethylenedioxythiophene (EDOT) and 0.1 M polystyrene sulfonic (PSS) acid as the supporting electrolyte. The PEDOT films were then characterized by cyclic voltammetry (CV) in the 0.1 M NaNO3 aqueous solution in order to obtain the optimized polymerization potential and charges where the PEDOT film would have a higher redox capacitance. Finally, the pH electrode was prepared by coating the SPCE/PEDOT(PSS) with a plasticized polyvinyl chloride (PVC) membrane containing tridodecylamine as hydrogen ionophore manually, and experiments were carried out to study the effect of the usage of PVC per square millimeter on the response time and stability of the electrode to optimize the PVC film thickness. The potentiometric response of the pH electrode was studied in the buffer solutions with pH ranging from 5.00 to 10.81 by the open-circuit potential (OCP) method. Experimental results show that the sensitivity of the electrode is  −55.7  ±  0.5 mV pH−1 (r2  >  0.9980) at room temperature (24  ±  1 °C) with pH ranging from 2.00–10.50, approximating to the theoretical nernstian slope (−59.16 mV pH−1),and the response time was less than 10 s. Moreover, it has low impedance, high accuracy and potential stability as well as some other useful properties such as pressure and heat resistance, hydrofluoric acid resistance, and it is not as fragile as the glass electrode.

研究领域: 分析化学 · 电化学 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。