Capillary electrophoresis (CE) is a versatile analytical separation method in the field of biochemistry. Although it has been proved that the relative molecular mass (Mr) of the polymers determines the threshold concentration of the entangled polymer solution, which will affect the separation performance of DNA molecules, there is still no report on the effect of Mron the separation performance of proteins. Herein, we have thoroughly performed the CE of proteins ranged from 14.3 kDa to 116 kDa in a mixed hydroxyethyl cellulose (HEC) solution. The mixed solution was obtained with various Mrincluding 90,000, 250,000, 720,000, and 1,300,000. Then, we found that the mixed polymer provided a high resolution for small protein molecules while increasing the efficiency of large ones. Results demonstrated that the migration time decreased if HEC (1,300,000) was mixed with the lower Mrone, and the mixed solution (1,300,000/250,000) offered the highest resolution. The resolution was negatively correlated with the electric field strength. Finally, we have employed the optimal electrophoretic conditions to separate proteins in human tears, and it showed that lysozyme, lipocalin, and lactoferrin from human tears were successfully resolved in the mixed HEC. Such work indicates that CE has the potential to be developed as a tool for the diagnosis of xerophthalmia, meibomian gland dysfunction, or other eye diseases.Keywords:capillary electrophoresis;protein separation;hydroxyethyl cellulose;relative molecular mass;flamingo
A novel photoelectrochemical (PEC) sensor based on “Z-scheme” TiO 2 @Au@CdS and molecularly imprinted polymer (MIP) was developed for the non-invasive detection of uric acid (UA). The “Z-scheme” material, consisting of an electron-transfer system (Au) and two isolated photochemical systems (CdS, TiO 2 ), was synthesized by chemical deposition method and it worked as a substrate for electro-polymerization of MIP. Due to the high photoelectric conversion efficiency provided by TiO 2 @Au@CdS and specific imprinting effect afforded by MIP, the sensor displayed desirable sensing performance with the merits of sensitivity, selectivity, repeatability, and stability. The linear range for UA detection is from 1 nM to 9 μM with the detection limit of 0.3 nM (S/ N = 3). Moreover, the assay was successfully utilized to measure UA in human tears and offered a reliable result. The incorporation of MIP and “Z-scheme” material into a PEC sensor system is expected to provide a promising strategy for detecting other small molecules. Graphical abstract