Xiaoyan Feng,Xiangyu Meng,Fangbin Xiao,Zoraida P. Aguilar,Hengyi Xu
Sepsis caused by bacteria has high morbidity and mortality, and it is neccerssay to establish a fast, convenient, and facility assays for detection of bacteria. In this study, we have developed established a simple, rapid, and ultrasensitive vancomycin (Van) and dendrimer nanoparticles-based method to isolate and detect bacteria in human blood using a multivalent binding strategy. The proposed Bio-den-Van multivalent capture nanoplatform combined with m-qPCR for simultaneous detection of two kinds of bacteria was demonstrated with rapid 2 min bacteria isolation with a linear range at 3.2 × 10 1 –3.2 × 10 6 CFU·mL -1 for L. monocytogenes and 4.1 × 10 1 –4.1 × 10 6 CFU·mL -1 for S. aureus , respectively. The limit of detection (LOD) for simultaneous detection of L. monocytogenes and S. aureus were 32 and 41 CFU·mL -1 in spiked human blood samples, respectively. Other bacteria had an insignificant interference with the test results. This Bio-den-Van multivalent capture nanoplatform combined with m-qPCR detection exhibited rapid, high sensitivity and specificity in simultaneous detection of various bacteria. To our knowledge, this is the first time that Bio-den-Van multivalent capture nanoplatform was used with Van as a recognition molecule for the simultaneous capture and subsequent detection of two bacteria from spiked human blood sample. This method holds great potential for future clinical applications.
Yujie Xue,Hongji Li,Xiaoyan Wang,Xiuwei Xuan,Mingji Li
The development of microelectrodes for the rapid in situ detection of neurotransmitters and their metabolic levels in human biofluids has considerable significance in biomedical research. In this study, self-supported graphene microelectrodes with B-doped, N-doped, and B- and N-co-doped vertical graphene (BVG, NVG, and BNVG, respectively) nanosheets grown on horizontal graphene (HG) were fabricated for the first time. The high electrochemical catalytic activity of BVG/HG on monoamine compounds was explored by investigating the influence of B and N atoms and the VG layer thickness on the response current of neurotransmitters. Quantitative analysis using the BVG/HG electrode in a blood-like environment with pH 7.4 indicated that the linear concentration ranges were 1–400 and 1–350 μM for dopamine (DA) and serotonin (5-HT), with limits of detection (LODs) of 0.271 and 0.361 μM, respectively. For tryptophan (Trp), the sensor measured a wide linear concentration range of 3–1500 μM over a wide pH range of 5.0–9.0, with the LOD fluctuating between 0.58 and 1.04 μM. Furthermore, the BVG/HG microelectrodes could be developed as needle- and pen-type sensors for the detection of DA, 5-HT, and Trp in human blood and gastrointestinal secretion samples.