文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
人IgG检测
Nanoscale · 2024 · IF 5.8

An enhanced SPR optical fiber biosensor using Ti3C2Tx MXene/AuNPs for label-free and sensitive detection of human IgG

Jiayi Zhu,Chao Zhao,Binyun Xia,Ning Wang,Xi Chen,Xinyue Jing,Minxuan Chen,Xinrui Xu

Abnormal human immunoglobulin G (IgG) may induce the risk of immune system disorder, infectious diseases, tumors and so on. However, the current detection methods exhibit low sensitivity, which limits their practical application. In this work, an SPR optical fiber sensor (SPR-OFS) with high sensitivity is designed for label-free detection of human IgG. It is fabricated using a heterostructure optical fiber coated with Au film/AuNPs and the Ti3C2Tx MXene biofunctionalized with goat anti-human IgG by polydopamine (PDA). In the experiment, the optimal thickness of the Ti3C2Tx MXene was explored and determined to be about 93 nm by comprehensively considering the refractive index (RI) sensitivity and spectral bandwidth of the SPR sensor. When the largest figure of merit (FOM) is calculated to be 17.8279 RIU−1, its RI sensitivity was ultimately found to be 2804.5 nm per RIU. The SPR-OFS was employed to detect human IgG within the concentration range of 0–30 μg mL−1 and its sensitivity is demonstrated to be 1.7046 nm (μg mL−1)−1. The SPR-OFS was also proved to have excellent linearity, specificity and stability. The proposed sensor offers outstanding performance with simple fabrication, providing a cutting-edge bioanalytical platform with potential applications in clinical diagnosis.

研究领域: 生物传感技术 · 医学诊断
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2019 · IF 6.393

Lab-on-tip: Protruding-shaped all-fiber plasmonic microtip probe toward in-situ chem-bio detection

Ling-Xin Kong,Yan-Xin Zhang,Wei-Gang Zhang,Yun-Shan Zhang,Tie-Yi Yan,Peng-Cheng Geng,Biao Wang

Lab-on-tip technology opens a new door for optical fiber surface plasmon resonance (SPR) sensors. In this paper, we first demonstrate an ultra-compact reflective SPR microtip probe on the flat fiber end in experiment, which has a length of tens of microns and a diameter of several microns. Simulations and experiments show that this new fiber SPR microtip probe coated with a nano-goldfilm has excellent refractive index (RI) sensing characteristic and great potential for biochemical detection at single cell level. Based on the high RI sensitivity, a bio-probe assembled with Chitosan/Polysodium Styrene Sulfonate (Cs/PSS) nano-polyelectrolyte film and the sheep anti-human IgG-HRP is prepared to recognize human IgG specifically. Due to the high surface sensitivity, the SPR microtip probe exhibits an ultra-low detection limit for human IgG. Due to the high bulk sensitivity and high thermo-optical coefficient (TOC) of polydimethylsiloxane (PDMS), a reference temperature probe based on SPR microtip is proposed, which is used to compensate for the temperature cross-sensitivity of the bio-probe. This new SPR microtip probe can be used not only in optical fiber sensor, but also in Tip-Enhanced Near-Field Raman Microscopy and Scanning Near-Field Optical Microscope.

研究领域: 光纤传感器 · 表面等离子体共振(SPR)技术 · 生化传感 · 纳米技术 · 显微镜
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。