文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
低串扰
MATERIALS & DESIGN · 2023 · IF 8.4

Fabrication of high-resolution, wide-range and low-crosstalk capacitive pressure sensing array for medical diagnosis

Shuheng Dong,Dedong Guo,Qingzhou Wang,Huixin Yu,Qing Xu,Ho-Kun Sung,Zhao Yao,Yuanyue Li,Yang Li

Flexible pressure sensors have found widespread application in medical diagnosis and human–computer interaction. These practical applications often require large-area pressure sensing arrays (PSAs) to explore spatial pressure distributions. However, the development of high-performance PSAs still presents significant challenges. Here, a new method is proposed for the fabrication of a high-resolution capacitive PSA in a 10 × 10 configuration. The array comprises the upper and lower electrode arrays of laser-induced graphene patterned on polyimide films, as well as the sandwiched dielectric units based on electrospun nanofiber membranes of H 3 PO 4 @PVPP (cross-linked polyvinyl pyrrolidone). Experimental results indicate that the PSA exhibits high sensitivity across a wide pressure range (0–200 kPa), while offering a rapid response/recovery time of 24/41 ms (at 1 kPa), an exceptionally low detection limit of ∼1.2 Pa, and a good stability of 4000 cycles. Moreover, the crosstalk of the PSA was found to be as low as 1.3%. By employing the PSA in conjunction with a convolutional neural network algorithm, a human foot-arch diagnostic system was developed for accurate detection and quantification of the plantar pressure for different types of foot arches. Such technology has significant potential in clinical detection and disease diagnosis of human foot.

研究领域: 生物医学工程 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
IEEE ELECTRON DEVICE LETTERS · 2023 ·Vol. 44 ·期 3 ·516-519 · IF 4.9

Stretchable Iontronic Pressure Sensor Array With Low Crosstalk and High Sensitivity for Epidermal Monitoring

Weihao Zheng,Yunlong Zhao,Hongcheng Xu,Yangbo Yuan,Weidong Wang,Libo Gao

Soft piezocapacitive sensor, owing to its simple assembly and low power consumption, draws intensive interests for physiological monitoring. However, crosstalk between proximity sensing units and limited mechanically stretching suppressed its practical application for conventional capacitive sensor array. Here we report a stretchable iontronic pressure sensor (SIPS) array with low proximate crosstalk for epidermal monitoring. Benefiting from electric double layer (EDL) capacitance effect between robust aramid nanofiber (ANF) /MXene (Ti3C2Tx) composite electrode and ionic film, the SIPS exhibits a high sensitivity up to 521.69 kPa−1, low limit of detection (0.22 Pa), broad linear sensing range (200 kPa) and rapid response time (17 ms) as well as long-term stable working durability for 10,000 cycles. The serpentine island bridge structure enables the SIPS array to stretch up to 40%, allowing pulse and grip monitoring of a bent wrist and finger, respectively, through processing circuits. This demonstrates the promising application prospects in vital physiological monitoring.

研究领域: 生物医学工程 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。