文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

5 项

设置提升方向
低噪声
Nano Energy · 2021 · IF 17.881

Low-noise X-ray PIN photodiodes made of perovskite single crystals by solution-processed dopant incorporated epitaxial growth

Xin Wang,Yubing Xu,Yuzhu Pan,Yuwei Li,Ji Xu,Jing Chen,Jun Wu,Qing Li,Xiaobing Zhang,Zhiwei Zhao,Chi Li,Elias E. Elemike,Damian C. Onwudiwe,Javed Akram,Wei Lei

X-ray photodiodes made of metal halide perovskites (MHPs) which directly convert X-ray photons into electron-hole pairs have shown advantages in low-cost and high X-ray detection sensitivity. However, lattice-mismatched blocking layers deposited by spin-coating or evaporation cannot fully limit the dark current and noise current under large reverse bias. In this work, Solution-processed dopant incorporated epitaxial growth is employed to form sufficient blocking barriers through epitaxially growing lattice-matched n-type MHPs (bismuth-doped) and p-type MHPs (silver-doped) on opposite faces of intrinsic CH 3 NH 3 PbBr 2.5 Cl 0.5 MHP single crystals. Through energy structure design, electron/hole blocking layers can form sufficient charges barriers, the X-ray PDs exhibit a low leakage dark current density of ~ 11 nA cm −2 under large reverse electrical field (over 500 V cm −1 ) and noise current of 47 fAHz −0.5 (1 mm 2 , over 500 V cm −1 ). The large external electrical field enables a state-of-art response speed (fall) of 750 ns, large X-ray detection sensitivity of 36.0 μ C mGy − 1 c m − 2 and the lowest detectable dose rate of 16 nGys −1 (40 kVp). This work will motivate new strategies to fabricate high-performance devices based on perovskites using solution-processed methods. These founding also explore a new generation of low dose and high dynamic X-ray detectors based on MHPs.

CAS / MDL: 67-68-5 68-12-2 96-48-0
研究领域: 材料科学 · 物理学 · 医学成像
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2025 · IF 13.2

Dual-interface MXene engineering for low-noise perovskite photodetectors in optical communication and health monitoring

Shareen Shafique,Haodong Wang,Yegang Lu,Taimoor Iqbal,Yuheng Wang,Baihui Shen,Ran Zhao,Li Sheng,Cheng Yang,Muhammad Salman,Fei Zheng,Ziyang Hu

Metal halide perovskite photodetectors (PDs) are attractive for next-generation optical communication and biomedical sensing owing to their high absorption coefficients, bandgap tunability, and solution-processability. However, their practical deployment is hindered by interfacial defects and ion migration, which result in high dark currents, noise, and limited operational stability. Here, we report a dual-interface (DI) engineering strategy that incorporates Ti 3 C 2 T x MXene simultaneously at the buried and top interfaces of the perovskite layer. This approach effectively passivates undercoordinated Pb 2+ /I − sites, suppresses trap-assisted recombination, and mitigates ion migration, thereby enabling ultralow-noise and fast-response devices. The optimized DI PD exhibits a suppressed dark current, a detectivity of 1.94 × 10 12 Jones, a responsivity of 0.44 A W −1 , and rise/fall times of 1.65/1.00 μs at 656 nm. The device retains >97 % of its performance after 60 days of nitrogen storage. Application demonstrations confirm error-free visible-light communication up to 10 kHz and precise photoplethysmography monitoring under varying illumination. This work highlights MXene-based DI engineering as a universal and scalable strategy for advancing high-performance perovskite PDs in data communication and healthcare technologies.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Nature Communications · 2019 ·Vol. 10 ·期 1 ·1-10 · IF 11.878

Heteroepitaxial passivation of Cs2AgBiBr6 wafers with suppressed ionic migration for X-ray imaging

Yang Bo,Pan Weicheng,Wu Haodi,Niu Guangda,Yuan Jun-Hui,Xue Kan-Hao,Yin Lixiao,Du Xinyuan,Miao Xiang-Shui,Yang Xiaoquan,Xie Qingguo,Tang Jiang

X-ray detectors are broadly utilized in medical imaging and product inspection. Halide perovskites recently demonstrate excellent performance for direct X-ray detection. However, ionic migration causes large noise and baseline drift, limiting the detection and imaging performance. Here we largely eliminate the ionic migration in cesium silver bismuth bromide (Cs 2 AgBiBr 6 ) polycrystalline wafers by introducing bismuth oxybromide (BiOBr) as heteroepitaxial passivation layers. Good lattice match between BiOBr and Cs 2 AgBiBr 6 enables complete defect passivation and suppressed ionic migration. The detector hence achieves outstanding balanced performance with a signal drifting one order of magnitude lower than all previous studies, low noise (1/ f noise free), a high sensitivity of 250 µC Gy air −1 cm –2 , and a spatial resolution of 4.9 lp mm −1 . The wafer area could be easily scaled up by the isostatic-pressing method, together with the heteroepitaxial passivation, strengthens the competitiveness of Cs 2 AgBiBr 6 -based X-ray detectors as next-generation X-ray imaging flat panels.

CAS / MDL: 7787-69-1
研究领域: 材料科学 · 物理学 · 放射学 · 医学成像
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Advanced Science · 2021 ·Vol. 8 ·期 14 ·2100075 · IF 16.806

Low-Noise Dual-Band Polarimetric Image Sensor Based on 1D Bi2S3 Nanowire

Wen Yang,Juehan Yang,Kai Zhao,Qiang Gao,Liyuan Liu,Ziqi Zhou,Shijun Hou,Xiaoting Wang,Guozhen Shen,Xinchang Pang,Qun Xu,Zhongming Wei

With the increasing demand for detection accuracy and sensitivity, dual-band polarimetric image sensor has attracted considerable attention due to better object recognition by processing signals from diverse wavebands. However, the widespread use of polarimetric sensors is still limited by high noise, narrow photoresponse range, and low linearly dichroic ratio. Recently, the low-dimensional materials with intrinsic in-plane anisotropy structure exhibit the great potential to realize direct polarized photodetection. Here, strong anisotropy of 1D layered bismuth sulfide (Bi 2 S 3 ) is demonstrated experimentally and theoretically. The Bi 2 S 3 photodetector exhibits excellent device performance, which enables high photoresponsivity (32 A W −1 ), I on / I off ratio (1.08 × 10 4 ), robust linearly dichroic ratio (1.9), and Hooge parameter (2.0 × 10 −5 at 1 Hz) which refer to lower noise than most reported low-dimensional materials-based devices. Impressively, such Bi 2 S 3 nanowire exhibits a good broadband photoresponse, ranging from ultraviolet (360 nm) to short-wave infrared (1064 nm). Direct polarimetric imaging is implemented at the wavelengths of 532 and 808 nm. With these remarkable features, the 1D Bi 2 S 3 nanowires show great potential for direct dual-band polarimetric image sensors without using any external optical polarizer.

研究领域: 光电子学 · 纳米光子学 · 偏振成像 · 低维材料 · 红外探测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2022 · IF 16.744

Weavable, large-scaled, rapid response, long-term stable electrochemical fabric sensor integrated into clothing for monitoring potassium ions in sweat

Lili Mo,Xiangda Ma,Longfei Fan,John H. Xin,Hui Yu

Currently, most electrochemical sensors use thin films , single fiber or yarn as sensing unit. However, the weaving process remains challenging along with properties such as a large sensing area, rapid response and long-term stable monitoring. Herein, an electrochemical fabric sensor was developed based on a skin-core structured sensing yarn for in-situ monitoring of potassium ion (K + ) concentrations in human sweat and this was achieved through a simple but novel electro-assisted core spinning technique (EACST). The nanofibers in the skin layer of the induction yarn showed excellent hydrophilicity and high specific surface area (8.85 m 2 /g) as well as significant differences in hydrophilicity and hydrophobicity of the warp and weft yarns of the fabric. As such, they could achieve absorption of sweat limit domain in the skin sensing area, so that the sensor can respond quickly within a short time (2.1 s) and achieve long-term stable sensing (above 6000 s). In addition, the sensor exhibited excellent selectivity , potential reproducibility as well as low noise and signal drift (3.6 × 10 −2  mV/s). The large-area (55 cm × 35 cm) of the electrochemical fabric sensor could also be sewn into clothing for integration onto the human body where it could effectively collect sweat for real-time in-situ monitoring of K + signals in human sweat.

研究领域: 材料科学 · 电化学 · 传感器 · 纺织工程 · 可穿戴技术 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。