文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

7 项

设置提升方向
便携式诊断
ACS Sensors · 2020 · IF 7.333

Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor

Xi Chen,Meng Wang,Gang Zhao

Monitoring of the hemostasis status is essential for therapeutic anticoagulants, undergoing surgery, cardiovascular diseases, etc. Although the clinical values of conventional blood coagulation tests have been well demonstrated, these devices have limitations such as large and expensive equipment, excessive sample volumes, long turnaround times, and difficulty in miniaturization for point-of-care use. Here, we present a novel strategy to evaluate blood hemostasis using the single-port Love-mode surface acoustic wave (SLSAW) sensor. The SLSAW sensor was designed as a plug-and-play-type unit for disposable use and operated under the harmonic resonant mode to produce frequency response to the blood coagulation cascade. Compared with a quartz crystal microbalance, Lamb wave, and film bulk acoustic resonator, the frequency shift of SLSAW was significantly increased, ranging from approximately 8960 to 10 368 kHz, which indicated enhancement of the signal-to-noise ratio. To demonstrate the feasibility of the SLSAW, studies were carried out to examine the effects of temperature and clotting reagents on coagulation times and kinetics. Activated partial thromboplastin times of plasma were validated by comparing with SYSMEX CA-7000 with the correlation (R2) as 0.996. In terms of coagulation kinetics, reaction time, clot formation time, maximum frequency shift, and clot formation rate of whole blood correlated well with corresponding parameters of the standard thromboelastography (TEG) analyzer (R2 = 0.9942, 0.9868, 0.9712, and 0.9939, respectively). The SLSAW sensor, with the advantages of low cost, small size, little sample consumption (1 μL), disposable use, and simple operation, is a promising tool for point-of-care diagnosis of hemostasis.

研究领域: 医学工程 · 生物医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2025 · IF 10.5

Synthesis of churros-like V2Se9 nanostructures for ultrasensitive electrochemical detection of oxalic acid in urine with portable point-of-care diagnostic devices

Peizheng Shi,Chen Ye,Zhuang Sun,Kaiqiang Sun,Ningbin Zhao,Mahan Pourfakhr,Tao Cai,Kazuhito Nishimura,Nan Jiang,Hsu-Sheng Tsai,Lidong Wu,Wenqi Wu,Jiancheng Yu,Li Fu,Lixin Xu,Jun Chen,Cheng-Te Lin

The binding of oxalic acid (OA) with metal ions, particularly calcium ions, is a key factor in kidney stone formation, as it produces insoluble calcium oxalate, which crystallizes and accumulates in the kidneys. Consequently, OA in urine is commonly considered a significant biomarker for clinical diagnosis and early screening of kidney stones. This study reports churros-like V 2 Se 9 nanostructures synthesized using a solvothermal method (high pressure and temperature) for sensitive and selective electrochemical detection of OA in urine. The electrodes made of churros-like V 2 Se 9 hybridized with reduced graphene oxide (rGO) for OA recognition, demonstrated a linear range from 20 nM to 4 mM, with an extremely low detection limit of 9.7 nM. To enable fast, user friendly, and accurate point-of-care testing (POCT) for OA in urine samples, we designed and developed a portable workstation integrated with smartphone for data visualization. This is the first study to utilize the V 2 Se 9 system for highly sensitive biosensor applications, highlighting its potential to advance screening techniques for key indicators of kidney stones by incorporating novel transition metal chalcogenide nanomaterials in POCT devices.

研究领域: 医学诊断 · 材料科学 · 纳米技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2024 · IF 10.7

Automated and ultrasensitive point-of-care glycoprotein detection using boronate-affinity enhanced organic electrochemical transistor patch

Jing Chen,Deqi Yang,Guoqi Zhu,Ru Zhang,Bingfang Wang,Zhiqiang Chang,Jing Dai,Wenjuan Wu,Menahem Y. Rotenberg,Yin Fang

Quantifying trace glycoproteins in biofluids requires ultrasensitive components, but feedback is not available in the current portable platforms of point-of-care (POC) diagnosis technologies. A compact and ultrasensitive bioelectrochemical patch was based on boronate-affinity amplified organic electrochemical transistors (BAAOECTs) for POC use was developed to overcome this dilemma. Benefit from the cascading signal enhancement deriving from boronate-affinity targeting multiple regions of glycoprotein and OECTs’ inherent signal amplification capability, the BAAOECTs achieved a detection limit of 300 aM within 25 min, displaying about 3 orders of magnitude improvement in sensitivity compared with the commercial electrochemical luminescence (ECL) kit. By using a microfluidic chip, a microcontroller module, and a wireless sensing system, the testing workflows of the above patch was automated, allowing for running the sample-to-answer pipeline even in a resource-limited environment. The reliability of such portable biosensing platform is well recognized in clinical diagnostic applications of heart failure. Overall, the remarkable enhanced sensitivity and automated workflow of BAAOECTs biosensing platform provide a prospective and generalized design policy for expanding the POC diagnosis capabilities of glycoproteins.

CAS / MDL: 937-14-4 1032678-42-4
研究领域: 生物医学工程 · 临床诊断 · 传感器技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
TALANTA · 2022 · IF 6.556

Visual detection of SARS-CoV-2 with a CRISPR/Cas12b-based platform

Yaqin Zhang,Xiangyu Quan,Yingchun Li,Hangyu Guo,Fange Kong,Jiahui Lu,Lirong Teng,Jiasi Wang,Di Wang

The coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a global pandemic, highlighting the unprecedented demand for rapid and portable diagnostic methods. Clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated (Cas) proteins-based platforms have been used for the detection of pathogens. However, in further applications and research, due to multiple steps needed, many methods showed an increased risk of cross-reactivity. The thermostable Cas12b enables the combination of isothermal amplification and CRISPR-mediated detection, which could decrease the risk of cross-contamination. In this study, we developed a portable and specific diagnostic method that combined the gold nanoparticle (AuNP) with thermal stable CRISPR/Cas12b-enhanced reverse transcription loop-mediated isothermal amplification (RT-LAMP), which is called SCAN, to distinguish the N gene of SARS-CoV-2 from flu gene. We validated our method using RNA from cells transfected by plasmids. We could easily distinguish the positive results by the naked eye based on the strong molar absorption coefficient of AuNP. Moreover, SCAN has the potential for high-throughput tests owing to its convenient operation. In sum, SCAN has broken the site and equipment restrictions of traditional detection methods and could be applied outside of hospitals and clinical laboratories, greatly expanding the test of COVID-19.

CAS / MDL: 51805-45-9
研究领域: 分子生物学 · 生物技术 · 病毒学 · 诊断医学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2021 · IF 9.229

Multichannel Paper Chip-Based Gas Pressure Bioassay for Simultaneous Detection of Multiple MicroRNAs

Lu Shi,Wei Liu,Baoxin Li,Chaoyong James Yang,Yan Jin

Simultaneous detection of multi-biomarkers not only enhances the accuracy of disease diagnosis but also improves detection efficiency and reduces cost. It is vital to achieve portable, simple, low-cost, and simultaneous detection of biomarkers for point-of-care (POC) diagnostics in a low-resource setting. Herein, a multichannel paper chip-based gas pressure bioassay was developed for the simultaneous detection of multiple biomarkers by combining multichannel paper chips with a portable gas pressure meter. Four DNA tetrahedral probes (DTPs) were used as capture probes and were immobilized in different detection zones of the paper chips to improve hybridization efficiency and reduce nonspecific adsorption. The formation of a sandwich structure between target microRNAs (miRNAs), the capture probe, and platinum nanoparticles (PtNPs)-modified complementary DNA (PtNPs-cDNA) transformed biomolecular recognition into quantitative detection of gas pressure. Four lung cancer-related miRNAs were detected simultaneously by a portable gas pressure meter. There is a good linear relationship between gas pressure and the logarithm of miRNA concentration in the range of 10 pM to 100 nM. Compared with single-stranded DNA capture probe, the signal-to-noise (S/N) of DNA tetrahedral probes improved more than 3 times. Using ring-oven washing, the unbound reagents in all channels of the paper chip were simultaneously and continuously washed away, leading to a more cheap, simple, and fast separation than magnetic separation. Therefore, it offers a promising multichannel paper chip-based gas pressure bioassay for portable and simultaneous detection of multiple biomarkers.

CAS / MDL: 16941-12-1
研究领域: 生物医学工程 · 分子诊断学 · 纳米技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOMEDICAL MICRODEVICES · 2023 ·Vol. 25 ·期 3 ·1-9 · IF 2.8

Ultrasensitive FET biosensor chip based on self-assembled organic nanoporous membrane for femtomolar detection of Amyloid-β

Cao Xiaona,Hu Xiaoping,Qiu Ziyi,Xu Ting,Yu Zhenhua,Li Zhe,Jin Huawei,Xu Bingzhe

Early diagnosis of Alzheimer’s disease (AD) is critical for preventing disease progression, however, the diagnosis of AD remains challenging for most patients due to limitations of current sensing technologies. A common pathological feature found in AD-affected brains is the accumulation of Amyloid-β (Aβ) polypeptides, which lead to neurofibrillary tangles and neuroinflammatory plaques. Here, we developed a portable ultrasensitive FET biosensor chip based on a self-assembled nanoporous membrane for ultrasensitive detection of Aβ protein in complex environments. The microscale semiconductor channel was covered with a self-assembled organic nanoporous membrane modified by antibody molecules to pick up and amplify the Aβ protein signal. The nanoporous structure helps protect the sensitive channel from non-target proteins and improves its stability since no chemical functionalization process involved, largely reduces background noise of the sensing platform. When a bio-gated target is captured, the doping state of the polymer bulk could be tuned and amplified the strength of the weak signal, achieving ultrasensitive detecting performance (enabling the device to detect target protein less than 1 fg/ml in 1 µl sample). Moreover, the device simplifies the circuit connection by integrating all the connections on a 2 cm × 2 cm chip, avoiding expensive and complex manufacturing processes, and makes it usable for portable prognosis. We believe that this ultrasensitive, portable, low-cost Aβ sensor chip shows the great potential in the early diagnosis of AD and large-scale population screening applications.

CAS / MDL: 919-30-2
研究领域: 生物传感器 · 神经科学 · 医学诊断 · 纳米技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Analytical Methods · 2021 ·Vol. 13 ·期 38 ·4442-4451 · IF 2.896

A simple unlabeled human chorionic gonadotropin biosensor based on a peptide aptamer

Huanhuan Li,Tongji Cai,Yi Ren,Jing Huang,Hanbing Jiang,Yucui Hou,Chunhua Tang,Jie Yang,Jia Zhao,Peng Yu

As an essential biochemical indicator in the fields of pregnancy and oncology, human chorionic gonadotropin (HCG) can be evaluated using colloidal gold immunochromatographic paper and quantified using a biochemical analyzer based on the principle of the antibody sandwich method. In view of the inaccuracy of the former and the complication of the latter, this study constructed an accurate, sensitive and simple unlabeled biosensor based on peptide aptamer CGGGPPLRINRHILTR for HCG detection. Molecular Operating Environment (MOE) was used to simulate the aptamer and protein docking, and western blot (WB) was used to verify the binding effect and ratio. The peptide aptamer was characterized and was then reduced with tris-(2-carboxyethyl)-phosphine hydrochloride (TCEP). After electrochemical deposition of chloroauric acid on the screen-printed electrode (SPE), the aptamer was self-assembled on the electrode surface under optimal conditions. The active site of the electrode surface was blocked with 6-mercapto-1-hexanol (MCH) and BSA. The electrochemical impedance spectrum (EIS) was used to quantify HCG in the matrix. Showing a good linear relationship in the range of 5–1500 mIU mL−1, with a detection limit of 1 mIU mL−1, the biosensor remained stable at room temperature for 14 days. Because of its small size, stability, sensitivity and accuracy, this biosensor has great potential to become a portable diagnostic device for HCG.

研究领域: 生物化学 · 生物传感器 · 分析化学 · 妊娠诊断 · 肿瘤学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。