文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

6 项

设置提升方向
光谱CT
CHEMICAL ENGINEERING JOURNAL · 2024 · IF 13.3

Enhanced sensitivity of spectral CT imaging in vivo by using Ytterbium chelate

Chunmei Yang,Didi Gu,Xin Zhu,Pan Han,Liping Pan,Xiaoling Che,Xinyao Chen,Qiuyu Meng,Guidong Dai,Lu Yang

Spectral CT can overcome the shortcomings of conventional CT, however, clinically used iodized contrast agents are not ideal for spectral CT imaging, which calls for the development of novel contrast agent with high attenuation coefficient. In this study, a small molecule lanthanide chelate Ytterbium-tetraazacyclododecane-1,4,7,10-tetraacetic acid (Yb-DOTA) was prepared by a simple and green one-step method, and it had multi-advantages such as good stability, excellent biocompatibility and high performance of spectral CT imaging in vitro and in vivo. In addition, Yb-DOTA had more prominent ability to visualize renal tissue, GI tract, the heart and venous system in both conventional and spectral CT imaging compared with clinical iohexol. Moreover, higher tissue contrast and enhanced sensitivity were achieved at high monochromatic energies (70–150 keV) after Yb-DOTA administration, indicating its superior spectral CT imaging performance. Yb-DOTA is expected to be a novel contrast agent to enhance the diagnostic sensitivity and accuracy.

CAS / MDL: 1611-35-4
研究领域: 医学影像学 · 分子影像 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
BIOMATERIALS · 2019 · IF 10.273

Bi-DTPA as a high-performance CT contrast agent for in vivo imaging

Weihua Liao,Peng Lei,Jinbin Pan,Cai Zhang,Xianting Sun,Xuejun Zhang,Chunshui Yu,Shao-Kai Sun

Clinically used iodinated computer tomography (CT) contrast agents suffer from low sensitivity, and the emerging lanthanide-chelates and CT imaging nanoagents raise great safety concerns. The fusion of high sensitivity and good biocompatibility is highly desired for the development of CT contrast agents. Herein, we propose a facile and green one-pot synthesis strategy for the fabrication of a small molecular CT contrast agent, Bi-diethylene triamine pentaacetate acid (DTPA) complex, for high-performance CT and spectral CT imaging. The Bi-DTPA exhibits yield of near 100%, outstanding water solubility, favorable biocompatibility, large-scale production capability, and superior X-ray attenuation ability, and is successfully applied in high-quality in vivo kidney imaging and gastrointestinal tract CT imaging and appealing spectral CT imaging. The proposed contrast agent can be rapidly excreted from body, avoiding the potential side effects caused by the long-term retention in vivo. Furthermore, our design shows great potential in developing diverse multifunctional contrast agents via chemical modification. The proposed Bi-DTPA with unique superiorities shows a bright prospect in clinic CT imaging, especially spectral CT imaging, and lays down a new way for the design of high-performance CT contrast agents with great clinical transformation potential.

研究领域: 医学影像学 · 生物医学工程 · 放射医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2019 · IF 8.456

Rhenium Sulfide Nanoparticles as a Biosafe Spectral CT Contrast Agent for Gastrointestinal Tract Imaging and Tumor Theranostics in Vivo

Xiaoyi Wang,Jiaojiao Wang,Jinbin Pan,Fangshi Zhao,Di Kan,Ran Cheng,Xuening Zhang,Shao-Kai Sun

Spectral computed tomography (CT) imaging as a novel imaging technique shows promising prospects in the accurate diagnosis of various diseases. However, clinically iodinated contrast agents suffer from poor signal-to-noise ratio, and emerging heavy-metal-based CT contrast agents arouse great biosafety concern. Herein, we show the fabrication of rhenium sulfide (ReS2) nanoparticles, a clinic radiotherapy sensitizer, as a biosafe spectral CT contrast agent for the gastrointestinal tract imaging and tumor theranostics in vivo by teaching old drugs new tricks. The ReS2 nanoparticles were fabricated in a one-pot facile method at room temperature, and exhibited sub-10 nm size, favorable monodispersity, admirable aqueous solubility, and strong X-ray attenuation capability. More importantly, the proposed nanoparticles possess an outstanding spectral CT imaging ability and undoubted biosafety as a clinic therapeutic agent. Besides, the ReS2 nanoparticles possess appealing photothermal performance due to their intense near-infrared absorption. The proposed nano-agent not only guarantees obvious contrast enhancement in gastrointestinal tract spectral CT imaging in vivo, but also allows effective CT imaging-guided tumor photothermal therapy. The proposed “teaching old drugs new tricks” strategy shortens the time and cuts the cost required for clinical application of nano-agents based on existing clinical toxicology testing and trial results, and lays down a low-cost, time-saving, and energy-saving method for the development of multifunctional nano-agents toward clinical applications.

研究领域: 医学影像学 · 纳米医学 · 肿瘤学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2022 ·Vol. 46 ·期 21 ·10458-10469 · IF 3.925

One-pot synthesis of flower-like Bi2S3 nanoparticles for spectral CT imaging and photothermal therapy in vivo

Cai Zhang,Li Zhou,Jing Zhang,Rui Dai,Pengrui Zhuang,Zhaoxiang Ye

Spectral computed tomography (CT) imaging agents are the key to spectral CT imaging with an unprecedented signal-to-noise ratio in vivo. However, there is still extreme lack of high-performance contrast agents. Herein, we present a facile and green strategy for the fabrication of uniform flower-like Bi2S3 nanoparticles (NPs) for spectral CT imaging and photothermal therapy in vivo for the first time. High-quality Bi2S3 NPs are obtained by simply heating the mixture of Bi(NO3)3 and glutathione in ethylene glycol without the need for adding toxic agents and inert gas protection. The proposed Bi2S3 NPs exhibit good monodispersity, high Bi content (60%), favorable water solubility, strong absorption in near-infrared windows, good biocompatibility and excellent CT and spectral CT imaging abilities due to the high K-edge energy of Bi (91 keV). Not only the accurate gastrointestinal tract spectral CT imaging but also the evaluation of the effect of intestinal obstruction surgery was achieved using the Bi2S3 NPs. Then effective tumor photothermal therapy in vivo was realized. This study proposes a facile and green method for the synthesis of high-quality Bi2S3 NPs, and proves the promising potential of Bi2S3 nanomaterial as a high-performance spectral CT imaging agent.

CAS / MDL: 70-18-8 298-93-1
研究领域: 材料科学 · 医学成像 · 纳米技术 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Advanced Science · 2021 ·Vol. 8 ·期 11 ·2002548 · IF 16.806

Harnessing X-Ray Energy-Dependent Attenuation of Bismuth-Based Nanoprobes for Accurate Diagnosis of Liver Fibrosis

Shiman Wu,Xianfu Meng,Xingwu Jiang,Yelin Wu,Shaojie Zhai,Xiaoshuang Wang,Yanyan Liu,Jiawen Zhang,Xinxin Zhao,Yan Zhou,Wenbo Bu,Zhenwei Yao

Timely detection of liver fibrosis by X-ray computed tomography (CT) can prevent its progression to fatal liver diseases. However, it remains quite challenging because conventional CT can only identify the difference in density instead of X-ray attenuation characteristics. Spectral CT can generate monochromatic imaging to specify X-ray attenuation characteristics of the scanned matter. Herein, an X-ray energy-dependent attenuation strategy originated from bismuth (Bi)-based nanoprobes (BiF 3 @PDA@HA) is proposed for the accurate diagnosis of liver fibrosis. Bi element in BiF 3 @PDA@HA can exhibit characteristic attenuation depending on different levels of X-ray energy via spectral CT, and that is challenging for conventional CT. In this study, selectively accumulating BiF 3 @PDA@HA nanoprobes in the hepatic fibrosis areas can significantly elevate CT value for 40 Hounsfield units on 70 keV monochromatic images, successfully differentiating from healthy livers and achieving the diagnosis of liver fibrosis. Furthermore, the enhancement produced by the BiF 3 @PDA@HA nanoprobes in vivo increases as the monochromatic energy decreases from 70 to 40 keV, optimizing the conspicuity of the diseased areas. As a proof of concept, the strategically designed nanoprobes with energy-dependent attenuation characteristics not only expand the scope of CT application, but also hold excellent potential for precise imaging-based disease diagnosis.

研究领域: 医学影像学 · 材料科学 · 肝脏疾病研究
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOMATERIALS · 2023 · IF 14

Beyond antioxidation: Harnessing the CeO2 nanoparticles as a renoprotective contrast agent for in vivo spectral CT angiography

Cai Feng,Zongling Xiong,Xianting Sun,Hao Zhou,Tianming Wang,Ying Wang,Harrison X. Bai,Peng Lei,Weihua Liao

It is a challenging task to develop a contrast agent that not only provides excellent image contrast but also protects impaired kidneys from oxidative-related stress during angiography. Clinically approved iodinated CT contrast media are associated with potential renal toxicity, making it necessary to develop a renoprotective contrast agent. Here, we develop a CeO 2 nanoparticles (NPs)-mediated three-in-one renoprotective imaging strategy, namely, i) renal clearable CeO 2 NPs serve as a one-stone-two-birds antioxidative contrast agent, ii) low contrast media dose, and iii) spectral CT, for in vivo CT angiography (CTA). Benefiting from the merits of advanced sensitivity of spectral CT and K-edge energy of Cerium (Ce, 40.4 keV), an improved image quality of in vivo CTA is successfully achieved with a 10 times reduction of contrast agent dosage. In parallel, the sizes of CeO 2 NPs and broad catalytic activities are suitable to be filtered via glomerulus thus directly alleviating the oxidative stress and the accompanying inflammatory injury of the kidney tubules. In addition, the low dosage of CeO 2 NPs reduces the hypoperfusion stress of renal tubules induced by concentrated contrast agents used in angiography. This three-in-one renoprotective imaging strategy helps prevent kidney injury from being worsened during the CTA examination.

CAS / MDL: 5949-29-1
研究领域: 医学影像 · 纳米技术 · 放射学 · 肾病学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。