文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
关节材料
TRIBOLOGY INTERNATIONAL · 2024 · IF 6.1

Coupling influence between environmental factors and synovial fluid components on tribological behavior of hip joint materials

Jiajia Cen,Qin Chen,Kai Chen,Xinyue Zhang,Haiyan Feng,Cunao Feng,Xiaowei Li,Dekun Zhang,Shirong Ge

Environmental factors greatly affect the tribological behavior of hip joint materials in synovial fluid. In this paper, four groups of the synovial fluid with different concentrations of albumin (Alb), γ-globulin (γ-Glo), hyaluronic acid (HA), and phospholipids (PLs) were prepared based on the concentration of each component of the synovial fluid after artificial joint replacement. Then, taking cobalt-chrome-molybdenum (CoCrMo) and high crosslinked polyethylene (XLPE) as research objects of the hip joint materials, the tribological behaviors in the synovial fluid with different pH values and temperature were systematically explored, elucidating the influence mechanisms of external conditions and synovial fluid components on friction and wear behaviors. Results indicated that the tribological behaviors of hip joint materials were significantly affected by the pH value and temperature of the synovial fluid. The coefficient of friction (COF) of the hip joint materials in the synovial fluid initially decreased and then increased with the pH value, reaching a minimum at pH= 8.0, and sample 4 was the most sensitive to pH change. The COF of the hip joint materials in the synovial fluid ascended with temperature, showing an opposite trend to calf serum (protein concentration of 30 mg/mL) in the standard experiment. In addition, the wear of the hip joint materials was more severe in the synovial fluid with lower pH (pH=7.5 and pH=8.0) and mild in the synovial fluid with higher pH (pH=8.5). Additionally, the wear of the hip joint materials in the synovial fluid and calf serum in the standard experiment increased with the ascend of temperature, and the wear in calf serum in the standard experiment was the most affected by temperature. In conclusion, this study sheds light on the tribological behaviors and mechanisms of artificial hip joints under simulated working conditions, providing a crucial foundation for accurately evaluating the bio-tribological characteristics of artificial joint materials.

CAS / MDL: 77-86-1
研究领域: 生物医学工程 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Lubricants · 2025 ·Vol. 13 ·期 1 ·31 · IF 2.9

The Low Friction Coefficient and High Wear Resistance UHMWPE: The Effect of Pores on Properties of Artificial Joint Materials

Chunmin Yang,Junhua Zhang,Honglin Yue,Xueqin Kang

Ultrahigh-molecular-weight-polyethylene (UHMWPE) is extensively applied to make bone and cartilage implants in the field of biomaterial application. UHMWPE matched with a metal or ceramic component withstands the long-term effect of cyclic stress, which induces UHMWPE serious wear, and affects the service life of the artificial joint. This investigation focuses on the influence of pores on the mechanical and tribological property of UHMWPE. The porosity, crystallinity, yield strength, tensile strength, hardness, compression yield strength, creep resistance, wettability, friction performance, and wear mechanism of solid and porous UHMWPE were evaluated and compared. The research results indicated that the pore had a remarkable influence on the mechanical, friction, and wear property of UHMWPE. The porosity of porous UHMWPE was 29.7% when 50 wt. % sodium chloride (NaCl) was added and the pore size was about 200 μm. The crystallinity, hardness, creep resistance, strength, and elongation decreased after NaCl was added and dissolved. However, the yield strength in the tensile and compression test was closer to that of the natural cartilage. The friction coefficient and wear loss of porous UHMWPE were higher than that of solid UHMWPE in dry conditions, but these values of porous UHMWPE were lower than that of solid UHMWPE in the calf serum lubrication condition. The main wear mechanism of porous and solid UHMWPE was abrasive. The lubricity of calf serum reduced wear surface scratches and furrows, especially for porous UHMWPE.

CAS / MDL: 7647-14-5
研究领域: 生物材料学 · 机械工程 · 医学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。