An ultrasensitive fluorescence sensing strategy for kanamycin (KANA) determination using endonuclease IV (Endo IV)-powered DNA walker, and hybridization chain reaction (HCR) amplification was reported. The sensing system consists of Endo IV-powered 3D DNA walker using for the specific recognition of KANA and the formation of the initiators, two metastable hairpin probes as the substrates of HCR and a tetrahydrofuran abasic site (AP site)-embeded fluorescence-quenched probe for fluorescence signal output. On account of this skilled design of sensing system, the specific binding between KANA and its aptamer activates DNA walker, in which the swing arm can move autonomously along the 3D track via Endo IV-mediated hydrolysis of the anchorages, inducing the formation of initiators that initiates HCR and the following Endo IV-assisted cyclic cleavage of fluorescence reporter probes. The use of Endo IV offers the advantages of simplified and accessible design without the need of specific sequence in DNA substrates. Under the optimal experimental conditions, the fluorescence biosensor shows excellent sensitivity toward KANA detection with a detection limit as low as 1.01 pM (the excitation wavelength is 486 nm). The practical applicability of this strategy is demonstrated by detecting KANA in spiked milk samples with recovery in the range of 98 to 102%. Therefore, this reported strategy might create an accurate and robust fluorescence sensing platform for trace amounts of antibiotic residues determination and related safety analysis.
Highly efficient fluorescence sensing of kanamycin using Endo IV-powered DNA Walker and hybridization chain, reaction amplification, Xiaonan Qu, Jingfeng Wang, Rufeng Zhang, Yihan Zhao, Shasha Li, Yu Wang, Su Liu*, Jiadong Huang, and Jinghua Yu, an ultrasensitive fluorescence sensing strategy for kanamycin determination using endonuclease IV-powered DNA walker, and hybridization chain reaction amplification is reported.
As an important base excision repair (BER) enzyme, uracil-DNA glycosylase (UDG) can repair the uracil-induced DNA lesion and maintain the genomic integrity. Herein, we have proposed a sensitive UDG assay based on the terminal deoxynucleotidyl transferase (TdT)-assisted formation of fluorescent copper nanoclusters (CuNCs). In this study, a uracil-containing stem-loop DNA substrate is rationally designed with its 3′-end blocked with 2′, 3′-dideoxycytosine (ddC). UDG can remove the uracil in the DNA substrate to generate an apurinic/apyrimidinic (AP) site, which can then be specifically cleaved by endonuclease IV (Endo IV) to expose a 3′-OH terminus. TdT will initiate the template-free DNA extension along the exposed 3′-OH terminus to produce a quite long poly(T) tail, which will perfectly template the production of fluorescent CuNCs. By recording the fluorescence of the CuNCs, the UDG activity can be faithfully detected. In contrast, if UDG is absent, the 3′-ddC terminus of the DNA substrate cannot be recognized by TdT and thus no TdT-based extension and formation of CuNCs will occur. The use of ddC as a 3′-end blocker can greatly decrease the nonspecific DNA extension and improve the signal-to-noise ratio. Furthermore, TdT is a template-free and sequence-independent DNA polymerase, which can effectively catalyze the tailing process up to a maximum of thousands of thymines , and each tail can form many fluorescent CuNCs. Therefore, an ultrahigh sensitivity is achieved and as low as 0.00005 U/mL of UDG can be clearly detected. Moreover, with an additional AP site-contained poly(A) oligonucleotide during TdT-mediated extension, a branched amplification mechanism is also preliminarily devised, which can further push the detection limit of UDG to an extremely low level of 0.000002 U/mL.