文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

2 项

设置提升方向
利奥西呱
JOURNAL OF CHROMATOGRAPHY A · 2023 · IF 4.1

Determination of vericiguat in rat plasma by UPLC-MS/MS and its application to drug interaction

Congyang Ding,Caihui Guo,Lingzhi Fang,Yajing Li,Zhi Wang,Zhanjun Dong

Vericiguat (VER) is a novel soluble guanylate cyclase stimulator treating symptomatic chronic heart failure (HF), and it is a substrate of both transporters P-glycoprotein and breast cancer resistance protein (BCRP). Astragaloside IV (ASIV) is the main active ingredient in Radix Astragali (Huangqi), a traditional Chinese medicine widely used for HF treatment in China. ASIV's effect on the protein expression of P-glycoprotein and BCRP has been observed, its impact on VER metabolism remain uncertain. In the present study, male Sprague-Dawley rats were administered with 20 mg/kg ASIV and 1 mg/kg VER to study their pharmacokinetics. Blood samples were subject to liquid-liquid extraction, and riociguat was employed as the internal standard (IS). The analytical method involved a C18 column (XSelect® HSS T3 column, 2.1 × 100 mm, 2.5 μm) with a mobile phase of 0.1% formic acid and acetonitrile for gradient elution. The flow rate of the mobile phase was set at 0.2 mL/min, and 5 µL of the sample was used for analysis. The positive ion multi-response monitoring mode was utilized with a transition of m/z 427.4→109.1 for VER and m/z 423.3→109.1 for the IS. The method exhibited good linearity within the concentration range of 0.1 to 300 ng/mL ( r  = 0.9987), and all the validation processes were conducted in accordance with the requirements of biological analysis. The pharmacokinetic results revealed that ASIV did not significantly alter the main parameters of VER, except for C max , which decreased by 33.2% (P < 0.05). Overall, our study successfully established a selective, sensitive and repeatable ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis for detecting VER in rat plasma.

CAS / MDL: 625115-55-1
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2024 · IF 4.9

Innovative approaches in electrochemical sensing for the sensitive and selective label-free detection of vericiguat in real blood samples

Nourhan M. Amaar,Fathi S. Awad,Wael I. Mortada,A.B. Abdallah

An innovative imprinted electrochemical platform was designed for the first time to detect vericiguat (VER), a soluble guanylate cyclase stimulator, in real samples. The smart sensor was fabricated by mixing a molecularly imprinted polymer (MIP) with graphite powder, obtained from a broken battery, and multiwalled carbon nanotubes (MWCNT) in the presence of paraffin oil. Density functional theory (DFT) was utilized not only to predict promising monomers for the polymerization process but also to investigate the interaction between the selected monomers and the VER template. Highly interactive acrylamide and methyl methacrylate monomers were first employed to interact with the VER template; then, the initiator, 2,2′-azobisisobutyronitrile, and the cross linker, ethylene glycol dimethacrylate, were added. The resulting MIP was characterized using different techniques including Fourier transform infrared spectroscopy, atomic force microscopy, scanning electron microscopy, and elemental mapping. The electrochemical performance of the synthesized sensor was investigated using cyclic voltammetry and electrochemical impedance spectroscopy. Using differential pulse voltammetry, the fabricated imprinted sensor was successfully utilized to monitor VER with a low limit of detection of 1.68 × 10 −9 mol L −1 over a linear concentration range of 5.1 × 10 −9 mol L −1 –2.3 × 10 −4 mol L −1 , with a correlation coefficient of 0.98. In addition, it showed excellent selectivity in the presence of other coexisting molecules, high stability (32 days), and good reproducibility (RSD = 4.68 %) and repeatability (RSD = 3.86 %). The proposed technique was successfully employed to detect VER in real blood samples and pharmaceutical tablets with quantitative extraction recovery (99.40 %–100.05 %).

CAS / MDL: 625115-55-1
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。