文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
前浓缩
CHEMICAL ENGINEERING JOURNAL · 2023 · IF 15.1

Study on pre-concentration of trace heavy metal ions in water quality detection using FO-electroosmotic integrated chip

Zhao Cui,Meng Zhang,Yang Yuan,Hui Jia,Huu Hao Ngo,Jie Wang

The focus of this study is on the enhanced concentration effect of the pump effect in forward osmosis (FO) and electroosmotic integrated chip. The study investigates the strengthening effect of the FO process, driven by the pump effect, on the electroosmotic flow process under the same energy consumption, using low-concentration heavy metal ions (Cr 3+ ) as the target enrichment. In the chip system, the pump effect, caused by capillary pressure difference, successfully replaces the osmotic pressure of the draw solution as a new driving force for the FO process. By adjusting the size and number of channels and avoiding errors, the study achieves the highest efficiency of the FO process in the chip, concentrating Cr 3+ from 1.26 × 10 −4 mol/L to 8.01 × 10 −4 mol/L (6.4 times) within 32 min. Excluding the influence of the electrokinetic (EK) limit of low-concentration samples, the concentration efficiency of an individual electroosmotic chip in this study is positively correlated with cross-nanochannel voltage (V cn ). The integrated FO and electroosmosis chip reduce the duration required to concentrate 50 mL Cr 3+ sample to the limit from 90 min to 16 min (5.6 times) compared to the single electroosmotic process. Furthermore, a series of Cr 3+ samples with concentrations below the detection limit of the UV–vis spectrophotometer were concentrated and detected by the integrated chip. The results indicate that the concentration limit of the FO-electroosmotic integrated chip for samples can increase the detection limit of Cr 3+ from 1.37 × 10 −4 mol/L to 3.67 × 10 −6 mol/L.

研究领域: 环境科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2015 ·Vol. 39 ·期 12 ·9714-9721 · IF 3.086

Preparation of an allyloxy-cucurbit[6]uril-modified polymer monolithic column for microextraction of estrogens in cosmetics

Yufeng Zhou,Naizhong Song,Haijiao Zheng,Xueju Lv,Bin Hu,Qiong Jia

In the present study, a poly(butyl methacrylate-co-ethylene dimethacrylate) (poly(BMA–EDMA)) monolithic column modified with allyloxy-cucurbit[6]uril (ACB[6]) was prepared with an in situ polymerization process. A polymer monolith microextraction method was developed with the modified monolithic column for the preconcentration of estrogen combined with high performance liquid chromatography. The various experimental parameters affecting the extraction capacity were investigated and optimized with an orthogonal experiment design, L16(45). Under the optimum conditions, we obtained acceptable linearities, low limits of detection, and good intra-day/inter-day relative standard deviations. Hydrophobic interactions, π–π stacking, and hydrogen bonding interactions contributed to the extraction efficiency of the ACB[6]@poly(BMA–EDMA) monolithic column. The present method was employed to determine estrogens in cosmetic samples and the accuracy was assessed through recovery experiments. The obtained recovery values were in the range of 80.1–109.4% with relative standard deviations less than 9.9%.

研究领域: 分析化学 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。