Wang Xiaojun,Li Runyu,Zeng Jinsong,Cheng Zheng,Wang Bin,Ding Qijun,Gao Wenhua,Chen Kefu,Xu Jun
Abstract Plant fiber isolated cellulose nanofibers (CNFs) are the materials with excellent mechanical properties. However, application of CNFs in polymer reinforcement is normally unsatisfactory due to its intertwined size distribution. Efforts to produce uniform sized CNFs have yet to be studied. In present work, spiral microchannel was used to fractionate CNFs based on the balance between inertial lift force (F L ) and Dean drag force (F D ) exerted on CNFs. The results showed that the smaller length of CNFs equilibrated near the inner microchannel while the larger length of CNFs occupied the equilibrium position away from the inner wall. With the increase of flowrates from 50 to 220 μL/min, fractionation efficiency between inner and middle outlet (E IM ) of spiral microchannel A with larger radius curvature (R) from 5 to 15 mm increased from 0 to 75.4%. However, stronger Dean flow attributing to decrease of R (3 mm to 10 mm) of single spiral microchannel B enabled satisfactory fractionation efficiency of 70.9% at flowrate of 90 μL/min. Moreover, the fractionation efficiency of double spiral microchannel with twice as length as microchannel A and three times as length as microchannel B was lower than that of single spiral microchannel at flowrate lower than 90 μL/min. Furthermore, this study exhibited a versatile and simple method for CNFs fractionation with high fractionation efficiency. Graphic abstract
We developed a new approach for particle separation by introducing viscosity difference of the sheath flows to form an asymmetric focusing of sample particle flow. This approach relies on the high-velocity gradient in the asymmetric focusing of the particle flow to generate a lift force, which plays a dominated role in the particle separation. The larger particles migrate away from the original streamline to the side of the higher relative velocity, while the smaller particles remain close to the streamline. Under high-viscosity (glycerol–water solution) and low-viscosity (PBS) sheath flows, a significant large stroke separation between the smaller (1.0 μm) and larger (9.9 μm) particles was achieved in a sample microfluidic device. We demonstrate that the flow rate and the viscosity difference of the sheath flows have an impact on the interval distance of the particle separation that affects the collected purity and on the focusing distribution of the smaller particles that affects the collected concentration. The interval distance of 293 μm (relative to the channel width: 0.281) and the focusing distribution of 112 μm (relative to the channel width: 0.107) were obtained in the 1042-μm-width separation area of the device. This separation method proposed in our work can potentially be applied to biological and medical applications due to the wide interval distance and the narrow focusing distribution of the particle separation, by easy manufacturing in a simple device.