文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

6 项

设置提升方向
参考区间
Metabolites · 2025 ·Vol. 15 ·期 2 ·106 · IF 3.7

Reference Intervals of Serum Metabolites and Lipids of a Healthy Chinese Population Determined by Liquid Chromatography-Mass Spectrometry

Yuqing Zhang,Jinhui Zhao,Hui Zhao,Xin Lu,Xueni Jia,Xinjie Zhao,Guowang Xu

Background:Metabolomics serves as a very useful tool for elucidating disease mechanisms and identifying biomarkers. Establishing reference intervals (RIs) of metabolites in a healthy population is crucial to the application of metabolomics in life sciences and clinics.Methods:We enrolled 615 healthy Chinese adults aged between 21 and 85 years. Their health status was ascertained through clinical examinations, biochemical parameters, and medical history. Targeted metabolomics and lipidomics analyses were applied to quantify 705 metabolites and lipids in the serum, establishing RIs and investigating the effect of sex and age on the metabolome and lipidome.Results:This study is the first large-scale effort in China to establish RIs for metabolites in the apparently healthy population. We found that most of the sex-related metabolites, including amino acids, acyl-carnitines and triacylglycerols, had higher concentrations in males, while the other sex-related lipids showed higher concentrations in females. Most of the age-related metabolites increased with age, including those associated with protein synthesis, nitric oxide synthesis, energy metabolism, and lipid metabolism.Conclusions:This study gives the reference intervals of the healthy Chinese metabolome and lipidome and their relationship with sex and age, which facilitates life sciences and precision medicine, especially for disease research and biomarker discovery.

CAS / MDL: 1634-04-4
研究领域: 生物化学 · 医学 · 代谢研究
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Bioanalysis · 2024 · IF 1.9

LC-MS/MS-based bioanalysis of branched-chain and aromatic amino acids in human serum

Tianyi Wang,Yalian Zhang,Luan Jia,Ying Li,Lu Wang,Yanru Zhu,Yuxin Jiang,Furong Zhao,Shuang Wang,Dan Song

Aim: Branched-chain amino acids (BCAAs) and aromatic amino acids (AAAs) were suggested as potential biomarkers in liver disease. This study aimed to develop and validate a simple and rapid LC-MS/MS method to simultaneously measure serum BCAAs and AAAs levels in patients with liver injury, and further establish reference intervals of Chinese healthy adult populations.Patients & methods: Samples were prepared by a one-step protein precipitation and analysis time was 4 min per run.Results: The validation results showed good linearity (r2 >0.9969), satisfactory accuracy (94.44% – 107.75%) and precision (0.10% – 5.90%).Conclusion: This method proved to be suitable for high-throughput routine clinical use and could be a valuable adjunct diagnosis tool for liver injury and other clinical applications.

CAS / MDL: 64-18-6
研究领域: 临床医学 · 生物分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF CLINICAL LABORATORY ANALYSIS · 2021 ·Vol. 35 ·期 8 ·e23870 · IF 2.352

Evaluation of a high-performance liquid chromatography method for urinary oxalate determination and investigation regarding the pediatric reference interval of spot urinary oxalate to creatinine ratio for screening of primary hyperoxaluria

Ying Shen,Xia Luo,Huijun Li,Qing Guan,Liming Cheng

Background Urinary oxalate can provide important clues for the screening and monitoring of children with primary hyperoxaluria (PH), which is a potentially life-threatening condition. However, little effort has been devoted to improve the oxalate assay in recent years. We have proposed a reliable and cost-effective high-performance liquid chromatography (HPLC) method for urinary oxalate determination. Methods Urine specimens were centrifuged after one-step derivatization, and the supernatants were subjected to HPLC analysis. Results The method was validated with consistent linearity from 0.0625 to 2.0 mmol/L with coefficients of variation ≤7.73%, good recovery, low carryover, satisfactory sample stability, and analytical specificity. The lower limit of quantification and the limit of detection were 0.03130 and 0.0156 mmol/L, respectively. Imprecision values were ≤2.92% and ≤16.6% for externally and internally produced controls, respectively. The pediatric reference interval of spot urinary oxalate to creatinine ratios was established together with its application in screening of PH in patients with renal diseases, revealing its successful deployment in our laboratory. Conclusions This reliable HPLC method could serve as a significant tool to determine urinary oxalate levels for screening and monitoring of children with PH in routine clinical laboratories.

CAS / MDL: 95-54-5
研究领域: 医学检验 · 临床化学 · 儿科医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
STEROIDS · 2022 · IF 2.76

Validity of the association between five steroid hormones quantification and female infertility conditions: A new perspective for clinical diagnosis

Yaqin Jia,Zhe Wang,Yuyi Feng,Meixian Wang,Lili Jiang,Zhijun Yu,Xiaoguang Shao,Guiyuan He,Yong Liu

Quantification of endogenous steroids and their precursors is essential for diagnosis of a wide range of causes for female infertility. However, immunoassays often overestimate concentrations due to assay interference by other endogenous steroids, especially at low concentrations. In addition, it still lacks of diagnostic reference intervals for five sex steroid hormones, including estradiol (E 2 ), 11-deoxycorticosterone (DOC), 17-hydroxyprogesterone (17-OHP 4 ), pregnenolone (P 5 ) and progesterone (P 4 ), which are crucial for distinguishing between normal individuals and female infertility. Therefore, we developed and validated a reliable and rapid ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous determination and quantification of five sex hormones, giving the reference intervals to accurately evaluate and diagnose female infertility. Our results showed that the developed UPLC-MS/MS assay was fast, high throughput, reproducible, specific, accurate, highly sensitive, and fully validated for simultaneous determination of P 5 , P 4 , 17-OHP 4 , DOC and E 2 in human follicular fluid. The simple sample preparation procedure in the current study gave reproducible and consistent recoveries. The validation results show that the UPLC-MS/MS assay has acceptable accuracy and precision at low concentrations, which permits their use in clinical study. In addition, our data gave the concentration range of five steroid hormones quantification in patients with female infertility and normal individuals. Our data can be used to accurately evaluate and diagnose female infertility.

CAS / MDL: 145-13-1
研究领域: 生殖医学 · 内分泌学 · 临床化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOMEDICAL CHROMATOGRAPHY · 2025 ·Vol. 39 ·期 10 ·e70136 · IF 1.7

Development of Mobile-Phase Buffers and Evaluation of Analytical Performance for HbA1c Assays

Yiyao Zhang,Guangyun Zhang,Fen Yang,Zhikang Zou

Hemoglobin A 1c (HbA 1c ) plays a role in the diagnosis and assessment of glycemic control in patients with diabetes. However, few studies have focused on the preparation methods and analytical performance evaluation of different formulations of mobile-phase buffers for HbA 1c assays. In this study, mobile-phase buffers of new formulations were prepared for the measurement of HbA 1c . Following the Clinical and Laboratory Standards Institute (CLSI) guidelines, the analytical performance of newly developed mobile-phase buffers was evaluated. The CVs of the intra- and inter-assay precision were less than 0.94%, the RDs of accuracy were less than ± 3.00%, and the carryover was 0.00%. The measured HbA 1c values were linear from 4.50% to 16.80% (26.00–160.00 mmol/mol). A comparison of newly developed and commercial mobile-phase buffers revealed that the Pearson regression equation was Y = 0.9862 x + 0.0888 ( R 2 = 0.9990), and the Bland–Altman mean difference between the two mobile-phase buffers was −0.02833% (95% CI: −0.1853% to 0.1278%). The chromatography column had a lifetime of over 7000 tests. The reference interval was 4.30%–6.30% (23.00–45.00 mmol/mol). Stability was acceptable within 24 months. The newly developed mobile-phase buffers demonstrated good analytical performance (i.e., precision, linearity, accuracy, carryover, reference interval, the number of chromatography column runs, and stability).

研究领域: 临床化学 · 糖尿病诊断 · 分析方法验证 · 色谱分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
CLINICA CHIMICA ACTA · 2025 · IF 2.9

A reliable LC-MS/MS method for urinary oxalate determination and its comparison with analogous assays

Ying Shen,Xia Luo,Qing Guan,Liming Cheng

Background The quantification of urinary oxalate is essential for the diagnosis of primary hyperoxaluria. This study sought to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for urinary oxalate determination and to evaluate its concordance with an established in-house high-performance liquid chromatography (HPLC) method and a commercial LC-MS/MS assay. Methods The newly developed LC-MS/MS method invloved the quantification of urinary oxalate through a straightforward single-step derivatization process using o -phenylenediamine at 120 °C for 20 min. A total of 291 urine samples were analyzed using both the in-house LC-MS/MS and HPLC methods, while 94 urine samples were evaluated using both our in-house LC-MS/MS method and a commercial LC-MS/MS assay. Additionally, a reference interval for 24-hour urinary oxalate in Chinese adults was established. Results Oxalate exhibited strong analytical retention in reverse-phase liquid chromatography. The newly developed LC-MS/MS method demonstrated excellent linearity with a correlation coefficient exceeding 0.995, and acheived recovery rates ranging from 92.80 % to 98.73 %. The intra-assay and inter-assay coefficients of variation (CVs) were between 0.79 % to 7.46 %, with a total CV ranging from 2.07 % to 7.50 %. No significant matrix effect was observed. However, discrepancies were identified between the in-house LC-MS/MS method and both the commercial LC-MS/MS assay and the HPLC method. The reference interval was established at 0.12–1.04 mmol/24 h (10.8–93.6 mg/24 h). Conclusions The developed LC-MS/MS method is robust and simple, providing a reliable tool for the clinical assessment of urinary oxalate. An accurate method is essential for screening analyses in primary hyperoxaluria.

CAS / MDL: 95-54-5
研究领域: 临床化学 · 分析化学 · 代谢性疾病 · 实验医学 · 质谱分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。