文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

1 项目

设置提升方向
双端设备
ACS Applied Materials & Interfaces · 2025 · IF 8.2

Dual-Terminal Ion-Modulation Multiplier-Based Ion-Doped Stacked Semiconducting Nanosheets for Multifunctional Biomedical Applications

Jiehua Zhang,Baobao Xu,Yiyi Yang,Zhixin Xie,Haihua Xu

Stacked semiconducting nanosheets (SSNs), which feature strong in-plane covalent bonds but weak van der Waals (vdWs) interactions between adjacent layers, hold substantial promise in next-generation, printable, and flexible devices. Among them, SSN-based transistors with high current multiplication offer significant potential for large-area, high-integration electronics and biomedical applications. However, the three-terminal configuration of the transistor inevitably increases the process step and power unit. Here, we demonstrate a dual-terminal ion modulation multiplier (IMM) based on ion-doped SSNs, which was obtained through a solution-processed and cost-effective method. We observed an ion-induced self-multiplication effect occurring in the IMM, which significantly enhanced the sensing performance, particularly in thermal sensing. The IMM thermal sensor exhibited a high resolution of 0.02 K and ultrahigh sensitivity of ∼27%/K, more than 7 times higher than that of ion-type thermal sensors. By combining the enhanced operational stability of IMMs, we successfully developed a dual-channel stretchable respiratory sensor (dSRS) based on IMMs, capable of real-time monitoring of subnasal respiratory signals. The dSRS effectively distinguished normal, rapid, and deep breathing states while accurately detecting abnormal respiration, including apnea and hypopnea. Utilizing the unique properties of IMMs, we developed a monolithically integrated and high-performance IMM glucose sensor with temperature compensation. This IMM glucose sensor demonstrated a high sensitivity of 0.91%/μM, a low detection limit of 100 nM, and a high detection accuracy under temperature interference. Our results clearly demonstrate that IMM devices endow SSNs with promising electrical and sensing capabilities, paving the way for next-generation electronics in the post-Moore era.

研究领域: 材料科学 · 生物医学工程 · 电子器件 · 传感技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。