JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
·
2017
·
IF 2.603
Xiangyu Li,Lujuan Liu,Hongjuan Wang,Jian Chen,Beibei Zhu,Huan Chen,Hongwei Hou,Qingyuan Hu
A stable method, using isotope dilution liquid chromatography-tandem mass spectrometry (LC–MS/MS), to simultaneously determine six aldehyde-DNA adducts was developed and applied to the analysis of human salivary DNA samples. The detection limit of these six DNA adducts was in the range of 0.006–0.014 ng/mL and that of the quantification limit was 0.017–0.026 ng/mL. The intra-day and inter-day precision of all aldehyde-DNA adducts was <10%. The analysis was completed within 25 min. Additionally, a noninvasive technique was used to collect the DNA samples from human saliva. The new method was successfully applied for the analysis of salivary DNA of nonsmokers and smokers. Five aldehyde-DNA adducts were detected in both smoker and nonsmoker salivary DNA, while α-Acr-dG was not detected in all the samples. Among these detected DNA adducts, no significant differences were found between smoker and nonsmoker (p > 0.05). This may due to the individual detoxifying differences or environmental and endogenous exposure. Our study provides a rapid and selective method to simultaneously detect six aldehyde-DNA adducts and to assess potential DNA damage induced by aldehydes,
研究领域:
分析化学
·
分子生物学
·
毒理学
✓ 已验证
DOI
高影响因子
JOURNAL OF CHROMATOGRAPHY A
·
2018
·
IF 3.716
Jiajia Niu,Xiaolei Zhao,Yuanyuan Jin,Guotao Yang,Zhonghao Li,Juanjuan Wang,Ruiqi Zhao,Zhongyue Li
A solid-phase microextraction (SPME) fiber coated with a two-dimensional porous organic framework (POF), JUC-Z2, was synthesized by a sol-gel process. The JUC-Z2-coated SPME fiber was combined with gas chromatography-mass spectrometry/mass spectrometry (GC–MS/MS), and a direct analysis method without any derivatization step was developed for the determination of two major harmful aromatic amines (1-naphthylamine, 1-NA; 2-naphthylamine, 2-NA) in the urine of amokers. The new method exhibited satisfactory linearity in the wide range of 0.05–100 μg L −1 with correlation coefficients (R) of 0.9999. The limits of detection are 0.010 and 0.012 ng L −1 . The relative standard deviations for repeated extraction (n = 6) with one fiber are less than 7.7%. The JUC-Z2-coated fiber demonstrates obviously superior extraction efficiencies for the two aromatic amines over the commercial fibers (CW/PEG, PA, PDMS/DVB, PDMS, CAR/PDMS, DVB/CAR PDMS). The structure-activity relationship was deeply investigated by the extraction comparison experiment with another similar POF material (PAF-48) and theoretical simulations. The extraction efficiencies of JUC-Z2 for 1-NA and 2-NA are 9.6 and 16.2 times higher than those of PAF-48, and JUC-Z2 has higher binding energies with the aromatic amines than PAF-48. The results indicate that the N atom on the JUZ-Z2 framework played a crucial role for adsorbing aromatic amines. Finally, the novel fiber has been successfully used to detect 1-NA and 2-NA in the urine of smokers.
研究领域:
分析化学
·
环境科学
·
医学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
CHEMICAL PHYSICS LETTERS
·
2023
·
IF 2.8
Huaqing Lin,Ming Yin,Chenjie Yang,Dongpo Xu,Chunhui Deng
Laser desorption/ionisation mass spectrometry (LDI-MS) can be used as an effective detection method for the analysis of more complex samples. However, the organic matrix of conventional LDI-MS produces large background interference and poor signal results, which hinders its application in metabolomics. Surface reconstruction can improve the performance of LDI-MS. In this study, mesoporous NiO@Pt nanofibre membranes were synthesised by a simple and efficient electrostatic spinning strategy and used as a matrix to significantly increase the intensity of mass spectrometry peaks. Metabolomic analysis of saliva samples from 18 smokers and 15 non-smokers was able to clearly distinguish the differences in salivary metabolism between smokers and non-smokers and showed good results in the qualitative analysis of salivary metabolism in smokers. Our study provides a rapid and convenient method for differentiating differences in salivary metabolism in smokers.
研究领域:
分析化学
·
代谢组学
·
医学诊断
✓ 已验证
产品关联
DOI
高影响因子
ANALYST
·
2022
·Vol. 147
·期 8
·1688-1694
·
IF 5.227
Huaqing Lin,Chenjie Yang,Ming Yin,Jingxuan Qiu,Wenjun Wang,Jie Lu,Dongpo Xu,Gang Li,Chunhui Deng
An effective matrix is very important for impact laser desorption/ionization mass spectrometry (LDI-MS), and the physicochemical properties of the matrix nanostructures can impact the LDI-MS performance. In this study, a simple and efficient single-nozzle electrospinning strategy using polystyrene (PS) spheres and polyvinyl pyrrolidone (PVP) to construct a mesoporous NiO@ZnO nanofiber membrane was developed. Compared with the NiO and ZnO nanomaterials alone, the obtained NiO@ZnO nanofiber membrane was proven to be an efficient material as the matrix to increase the intensity of the mass spectrum speaks of small molecules. The NiO@ZnO nanofiber membrane was used as the matrix for the LDI-MS method for the urine metabolism analysis of smokers, which revealed differences in the metabolic and the possible metabolic markers of smokers through the statistical analysis of the urine samples of 27 smokers and 11 nonsmoker controls.
研究领域:
分析化学
·
医学
·
材料科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHROMATOGRAPHY A
·
2025
·
IF 4
Yuxuan Li,Yuanjie Shan,Chenglong Yu,Xi-Ling Li,Jun Zhe Min
Smoking is detrimental to health. However, the potential of dynamic changes in chiral thiol compounds in human saliva, both before and after smoking, as indicators of oxidative stress in vivo remains unexplored. A novel ultra-high-performance liquid chromatography high-resolution mass spectrometry (UHPLC HRMS) method was developed for the simultaneous separation of four DL-thiol compounds in human saliva, utilizing a new ( R )-(5-(3-isothiocyanatopyrrolidin-1-yl)-5-oxopentyl (NCS-OTPP) pre-column derivatization approach. Chromatographic separation was carried out using a YMC Triart C18 column (2.0 × 150 mm, 1.9 µm), with isocratic elution of 0.1 % formic acid aqueous solution and 0.1 % formic acid methanol-acetonitrile (7:3, v/v ) at a ratio of 65:35. Separation of DL-glutathione (GSH), DL-cysteine (Cys), DL-homocysteine (Hcy), and γ-glutamylcysteine (γ-Glu-Cys) achieved resolution degrees of 1.60–1.89, with complete separation. Linear calibration was observed (R 2 ≥ 0.9992) within a range of 0.5–20 µM, with detection limits spanning 2.50–14.40 fmol. The intraday and interday precisions ranged from 0.33 % to 9.64 %, while average spiked recoveries were 92.15–106.22 %. This method was successfully applied to assess the four DL-thiol compounds in the saliva of 10 smokers and 10 non-smokers at different time points. Results revealed significantly higher concentrations of the DL-thiol compounds in the saliva of smokers compared to non-smokers, with significant differences for l-GSH, DL-Cys, and l-Hcy ( p < 0.05), returning to baseline levels within 15 min. Dynamic monitoring curves before and after smoking exhibited consistent trends with the fitted curves. This study introduces a new method for monitoring dynamic changes in DL-thiol compounds in saliva and offers insight into potential subhealth indicators linked to abnormal chiral thiol metabolism in vivo.
研究领域:
分析化学
·
生物化学
·
临床化学
·
质谱学
·
公共卫生
✓ 已验证
产品关联
DOI
PubMed
高影响因子