Liying Peng,Lei Hua,Enyou Li,Weiguo Wang,Qinghua Zhou,Xin Wang,Changsong Wang,Jinghua Li,Haiyang Li
Ion mobility spectrometry (IMS) is a promising non-invasive tool for the analysis of exhaled gas and exhaled nitric oxide (NO), a biomarker for diagnosis of respiratory diseases. However, the high moisture in exhaled gas always brings about extra overlapping ion peaks and results in poor identification ability. In this paper, p-benzoquinone (PBQ) was introduced into IMS to eliminate the interference of overlapping ion peaks and realize the selective identification of NO. The overlapping ions caused by moisture were titrated by PBQ and then converted to hydrated PBQ anions (C6H4\text{O}_{2}^{-}(H2O)n). The NO concentration could be determined by quantifying gas phase hydrated nitrite anions (N\text{O}_{2}^{-}(H2O)n), product ions of NO. Under optimized conditions, a limit of detection (LOD) of about 1.4 ppbv and a linear range of 10–200 ppbv were obtained for NO even in 100% relative humidity (RH) purified air. Furthermore, this established method was applied to measure hourly the exhaled NO of eight healthy volunteers, and real-time monitoring the exhaled NO of an esophageal carcinoma patient during radical surgery. These results revealed the potential of the current dopant titrating IMS method in the measurement of exhaled NO for medical disease diagnosis.
Rationale Exhaled breath can be used for early warning of disease, with organic nitrogen compounds, including triethylamine (TEA), being linked to various medical conditions. Surface ionization ion mobility spectrometry (SI-IMS) facilitates the direct detection of TEA in exhaled breath. However, the presence of multiple ionization products of TEA poses challenges for both quantitative and qualitative analyses. Methods A doped surface ionization (DSI) method consisting of surface ionization of dopants and gas-phase reaction of samples was proposed, and TEA was detected when combined with an ion mobility spectrometer. TEA at different concentrations and spiked by human breath was detected to evaluate the method's properties. Results TEA with concentrations from 5.99 to 30.50 ppb and a relative humidity of 80% was detected. The peak intensity of the protonated TEA ions demonstrated a linear correlation with concentration, yielding a fitted correlation coefficient of R 2 = 0.94. A standard deviation less than 0.066% was obtained with 10 replicate analyses of 29.92 ppb TEA, and the recovery rate of the sample was 93.57%. Conclusions The SI-IMS based on the DSI method has the advantages of excellent selective ionization, high accuracy and sensitivity, and remarkable repeatability for detecting TEA. It is a promising method for detecting specific organic nitrogen compounds in exhaled breath.