文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
均方误差
TALANTA · 2024 · IF 5.6

Exploring the analytical potential of total reflection X-ray fluorescence (TXRF) combined with partial least square (PLS) for simple determination of ash content in various coal types

Yongsheng Zhang,Jian Yuan,Rui Gao,Yang Zhao,Zefu Ye,Zhujun Zhu,Peihua Zhang,Lei Zhang,Wangbao Yin,Suotang Jia

Ash content, as a crucial indicator of coal quality, its rapid and accurate determination is pivotal to improve the energy utilization of coal and reduce environmental pollution. Traditional spectroscopic methods face significant challenges in acquiring accurate information from coal samples due to the notorious matrix effects arising from their complex composition, vast molecular structure, and diverse coal types. In this study, the feasibility of total reflection X-ray fluorescence (TXRF) combined with partial least squares (PLS) for the determination of coal ash was firstly investigated based on the TXRF being unaffected by matrix effects. Firstly, coal samples were prepared as suspensions, and the effects of sample particle size and different dispersants on the results of TXRF analyses were evaluated. The accuracy and applicability of the chosen sample preparation strategies were further validated using inductively coupled plasma mass spectrometry (ICP-MS) and two certified reference materials (CRMs). Subsequently, based on the analysis of 19 coal samples, the impact of three different predictive variables on the performance of the PLS model was investigated: (a) TXRF full spectrum normalized by the net intensity of the internal standard; (b) net intensity of characteristic peaks for 12 elements (Al, Si, K, Ca, Ti, Fe, Cr, Mn, Cu, Ni, and Sr) normalized by the net intensity of the internal standard; (c) concentrations of the aforementioned 12 elements. The results demonstrate that the PLS model constructed usingthe TXRF full spectrum normalized by the net intensity of the internal standard exhibits the best predictive capabilities, with the determination coefficient of calibration set (R 2 ) and mean square error (MSE) of the prediction set reaching 0.9736 and 0.99 %, respectively. Moreover, the measurement accuracy of this model was six times greater than that obtained with traditional X-ray fluorescence (XRF). Presented analytical results display the possibilities of combining TXRF with PLS for coal quality evaluation.

CAS / MDL: 7697-37-2
研究领域: 分析化学 · 环境科学 · 能源资源
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。