文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
基体效应
ANALYTICA CHIMICA ACTA · 2021 · IF 6.558

Quantitative analysis of lithium in brine by laser-induced breakdown spectroscopy based on convolutional neural network

Pengju Xing,Junhang Dong,Peiwen Yu,Hongtao Zheng,Xing Liu,Shenghong Hu,Zhenli Zhu

In this study, a simple and effective method for accurate determination of lithium in brine samples was developed by the combination of laser induced breakdown spectroscopy (LIBS) and convolutional neural network (CNN). Our results clearly demonstrate that the use of CNN could efficiently overcome the complex matrix effects, and thus allows for on-site Li quantitative determination in brine samples by LIBS. Specifically, two CNN models with different input data (M-CNN with matrix emission lines, and DP-CNN with double Li lines) were constructed based on the primary matrix features on spectrum and Boltzmann equation , respectively. It was observed that DP-CNN model could greatly improve the accuracy of Li analysis. We also compared the quantitative analysis capabilities of DP-CNN model with partial least squares regression (PLSR) and principal component analysis-support vector regression (PCA-SVR) model, and the results clearly showed DP-CNN offers the best quantification results (higher accuracy and less matrix interference). Finally, five real brine samples were successfully analyzed by the proposed DP-CNN model, confirming by the average absolute error of the prediction of 0.28 mg L −1 and the average relative error of 3.48%. These results clearly demonstrate that input data plays an important role in the training of CNN model in LIBS analysis, and the proposed DP-CNN provides an effective approach to solve the matrix effects encountered in LIBS for Li measurement in brine samples.

研究领域: 分析化学 · 人工智能应用 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY · 2022 ·Vol. 38 ·期 1 ·142-155 · IF 4.351

High-precision double-spike Sn isotope analysis of geological materials by MC-ICP-MS

Jia-Xin She,Weiqiang Li,Shichao An,Yuanfeng Cai

Stable Sn isotopes have the potential to constrain the behavior of Sn in various natural and anthropogenetic processes, however, studies on stable isotopes of Sn for terrestrial rock samples have been limited. Here, we present a high-precision Sn isotope analytical method of geological samples by the double spike technique. Samples were equilibrated with a 117Sn–122Sn double spike during dissolution, then Sn was purified from the rock matrix using TRU spec resin. The purified Sn solutions were analyzed on a Nu 1700 Sapphire MC-ICP-MS, and data reduction was performed using Newton–Raphson iteration. Effects of acid mismatch, concentration mismatch, and matrix elements were systematically tested to evaluate their impact on the accuracy and repeatability of the measurements. We show that the mismatch of acidity exerts negligible influences on the Sn isotope analysis. By contrast, the accuracy of Sn isotopic measurements could be compromised if the Sn concentration of the sample is below 40% of that of the standard. To ensure the accuracy of Sn isotope analysis, the concentration match between the sample and standard should be better than ±20%. When the measured solution has varying mass ratios of [X]/Sn (ng g−1/ng g−1) lower than 0.5 for Mg, Ca, Fe, Ti, U, Ni, Ag, As, Ru, and Mo, the measured Sn isotope composition was not affected. However, Cd in Sn samples could affect the accuracy of Sn isotope analysis by the 117Sn–122Sn double spike through the generation of 116CdH+ in plasma that interferes with 117Sn+. The Cd/Sn ratio needs to be below 0.01 to ensure analytical accuracy by the double spike method. The accuracy of this method was further verified by measuring the pure solution with both double spike and sample standard bracketing methods, as well as processing a synthetic solution through column chemistry. The Sn isotope compositions of geological samples measured using our method are reproducible and consistent with previous data from other laboratories. Additionally, Sn isotope data for geological reference materials BIR-1, RGM-1, and GSR-1 are reported for the first time. Based on repeated analyses of pure and geological reference materials, the long-term intermediate precision is better than ±0.069‰ on δ122/118Sn for a spiked solution of 100 μg g−1.

研究领域: 地球化学 · 分析化学 · 地质学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
TALANTA · 2024 · IF 5.6

Exploring the analytical potential of total reflection X-ray fluorescence (TXRF) combined with partial least square (PLS) for simple determination of ash content in various coal types

Yongsheng Zhang,Jian Yuan,Rui Gao,Yang Zhao,Zefu Ye,Zhujun Zhu,Peihua Zhang,Lei Zhang,Wangbao Yin,Suotang Jia

Ash content, as a crucial indicator of coal quality, its rapid and accurate determination is pivotal to improve the energy utilization of coal and reduce environmental pollution. Traditional spectroscopic methods face significant challenges in acquiring accurate information from coal samples due to the notorious matrix effects arising from their complex composition, vast molecular structure, and diverse coal types. In this study, the feasibility of total reflection X-ray fluorescence (TXRF) combined with partial least squares (PLS) for the determination of coal ash was firstly investigated based on the TXRF being unaffected by matrix effects. Firstly, coal samples were prepared as suspensions, and the effects of sample particle size and different dispersants on the results of TXRF analyses were evaluated. The accuracy and applicability of the chosen sample preparation strategies were further validated using inductively coupled plasma mass spectrometry (ICP-MS) and two certified reference materials (CRMs). Subsequently, based on the analysis of 19 coal samples, the impact of three different predictive variables on the performance of the PLS model was investigated: (a) TXRF full spectrum normalized by the net intensity of the internal standard; (b) net intensity of characteristic peaks for 12 elements (Al, Si, K, Ca, Ti, Fe, Cr, Mn, Cu, Ni, and Sr) normalized by the net intensity of the internal standard; (c) concentrations of the aforementioned 12 elements. The results demonstrate that the PLS model constructed usingthe TXRF full spectrum normalized by the net intensity of the internal standard exhibits the best predictive capabilities, with the determination coefficient of calibration set (R 2 ) and mean square error (MSE) of the prediction set reaching 0.9736 and 0.99 %, respectively. Moreover, the measurement accuracy of this model was six times greater than that obtained with traditional X-ray fluorescence (XRF). Presented analytical results display the possibilities of combining TXRF with PLS for coal quality evaluation.

CAS / MDL: 7697-37-2
研究领域: 分析化学 · 环境科学 · 能源资源
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。