文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
基本紫1
ANALYTICAL AND BIOANALYTICAL CHEMISTRY · 2020 ·Vol. 412 ·期 5 ·1087-1096 · IF 3.637

Redox-derivatization reaction-based rapid and sensitive determination of nitrite using resonance Rayleigh scattering method

He Jincan,Zhong Zihui,Tan Shiying,Wu Fuhai,Bai Yan

It remains a problem for direct detection of small inorganic nitrite ions using resonance Rayleigh scattering (RRS) method based on the direct dye-binding reaction. In the present study, a redox-derivatization reaction taking only 5 min was introduced prior to nitrite detection. In the redox-derivatization reaction, nitrite ions were reduced by excess iodine ions to generate triiodide ions (I 3 − ), which were further derivatized with a cationic dye (basic violet 1, BV1) to form the ion associates of I 3 − -BV1. Therefore, the RRS signal was significantly enhanced, resulting from the increase of particle size and resonance-enhanced scattering effect. The analytical procedure was performed by just mixing nitrite, oxidant, acid, and dye all-in-one, avoiding the tediousness of a multi-step process or the preparation of nanoparticles. The whole detection process including the redox-derivatization reaction was less than 6 min. The reaction conditions such as concentration of hydrochloric acid, potassium iodide, and BV1, reaction time, and temperature were investigated. Under optimum conditions, the concentration of nitrite was linear with an RRS signal of I 3 − -BV1 ion associates at 320 nm in the range of 0.015–1.2 mg/L. The limit of detection (LOD) was calculated to be 3.0 μg/L. The RRS method was applied to the determination of nitrite in real samples such as pork sausage, milk powder, and water with recovery of 95.2–112%. With advantages of rapidness, high sensitivity, and high selectivity, the method indicates potential applicability for detection of nitrite in complex samples. The method also provides an instructive protocol for detection of analytes that generate no/weak RRS enhancement after the direct dye-binding reaction. Graphical abstract

CAS / MDL: 7681-11-0
研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。