文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
声学空化
APPLIED ACOUSTICS · 2024 · IF 3.4

Enhanced microbubble-mediated cavitation by using acoustic droplet vaporization

Jing Cao,Honghui Xue,Yinuo Zheng,Ling Wang,Litao Sun

Acoustic cavitation serves various therapeutic purposes, with both microbubbles and phase-transit droplets serving as potential cavitation nuclei. This project focused on investigating the intricate interaction between microbubbles and droplets and the resultant impact on acoustic cavitation. To facilitate this investigation, microbubbles with a negative potential of −51.58 mV were prepared, while droplets were endowed with a positive potential of +4.22 mV, facilitating the formation of microbubble-droplet clusters. Microscopic analysis was employed to observe the morphology of these clusters, revealing an initial mean size of 4.85 µm before ultrasound activation and subsequent transformation into larger bubbles with a mean size of 12.54 µm after ultrasound activation. The experimental approach involved the use of varying driven voltages to generate ultrasound waves with different intensities. A passive cavitation detector (PCD) was then employed to capture cavitation signals. Results demonstrated that, when maintaining a microbubble ratio of 50% and varying droplet ratios from 0% to 50%, the driven voltage at which the cavitation peak appeared decreased from 180 mV to 140 mV. Additionally, the mean cavitation intensity exhibited an initial increase from 0.58 to 0.78, followed by a subsequent decrease from 0.78 to 0.63 after normalization. This study provided valuable insights into the dynamic interactions between microbubbles and droplets. Specifically, it showed that microbubble cavitation transferred energy to droplets, leading to the generation of larger bubbles and higher cavitation intensity. Nevertheless, the observed cavitation intensity and threshold were contingent upon the ratios of microbubbles and droplets. Notably, to achieve an ideal cavitation intensity, the energy generated by microbubble cavitation must be substantial enough to activate all droplets, inducing acoustic droplet vaporization (ADV) and cavitation.

研究领域: 医学超声 · 生物医学工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2022 · IF 16.744

Parametrical investigation of acoustic cavitation and extraction enhancement in ultrasonic microreactors

Shuainan Zhao,Chaoqun Yao,Lixue Liu,Guangwen Chen

Experimental studies on acoustic cavitation and ultrasound-assisted extraction process were systematically investigated in the laboratory-built ultrasonic microreactors. The cavitation evolution process of microbubble after ultrasound exposure was first analyzed, finding that surface tension plays a vital role on bubble oscillation. The effects of fluid property as well as ultrasound frequency on cavitation activity were then investigated, and a discriminating criterion was established on the basis of experimental data, which can well predict the bubble cavitation mode. In addition to acoustic cavitation, the effects of varying parameters, e.g., ultrasound frequency, input mode, on ultrasound-assisted extraction process were also investigated, the result of which, correlates well with the cavitation research from a meso-scale perspective. It was found that the overall mass transfer coefficients are solely related to the specific energy dissipation rate under all circumstances. At specific energy dissipation rate 3–675 W/kg, the overall mass transfer coefficients were measured to be 0.01–0.24 s −1 , being comparable to that of reciprocating plate column and far high than the passive microreactor.

CAS / MDL: 121-33-5
研究领域: 化学工程 · 声化学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。