文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
声溶栓
ULTRASOUND IN MEDICINE AND BIOLOGY · 2022 · IF 3.694

Enhanced Sonothrombolysis Induced by High-Intensity Focused Acoustic Vortex

Shifang Guo,Zhen Ya,Pengying Wu,Lei Zhang,Mingxi Wan

High-intensity focused ultrasound (HIFU) thrombolysis provides a targeted and non-invasive therapy for thrombosis-related diseases. Rapid thrombolysis and restoration of blood flow are vital to reduce the disability and death rate . The objective of this study was to explore the feasibility of using a high-intensity focused acoustic vortex (HIFAV) to enhance sonothrombolysis. The in vitro clots were treated with HIFU with a peak negative pressure (PNP) of 2.86 MPa (HIFU A) or 3.27 MPa (HIFU B) or HIFAV with a PNP of 2.14 MPa. The results revealed that HIFAV thrombolysis could achieve a significantly higher efficiency than HIFU (HIFAV: 65.4%, HIFU A: 24.1%, HIFU B: 31.6%, p < 0.01), even at a lower intensity. The average size of the debris particles generated in HIFAV thrombolysis was similar to that in HIFU. Additionally, the cavitation activities were found to be more intense in HIFAV thrombolysis. Although the efficiency of HIFAV thrombolysis was higher when the pulse repetition frequency increased from 100 to 500 Hz (41.4% vs. 65.4%, p < 0.05), it decreased when the PRF reached 1000 Hz (29.9%). Lastly, it was found that increasing the duty cycle from 5% to 15% led to a higher efficiency in HIFAV thrombolysis (40.3% vs. 75.2%, p < 0.001). This study illustrated that HIFAV provided enhanced thrombolysis and that its efficiency could be further increased by optimizing the ultrasound parameters.

研究领域: 生物医学工程 · 超声治疗 · 血栓性疾病
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ADVANCED MATERIALS · 2021 ·Vol. 33 ·期 25 ·2007073 · IF 30.849

Surface Wettability of Nanoparticle Modulated Sonothrombolysis

Qingyuan Wu,Fengrong Zhang,Xueting Pan,Zhijun Huang,Zhijie Zeng,Hongyu Wang,Jun Jiao,Xiaolu Xiong,Lixin Bai,Dongsheng Zhou,Huiyu Liu

Sonodynamic therapy (SDT) is a non-invasive and highly penetrating treatment strategy under ultrasound irradiation. However, uncertainty in the mechanism of SDT has seriously hindered its future clinical application. Here, the mechanism of SDT enhanced by the wettability of nanoparticles is investigated. Nanoparticles can adsorb and stabilize nanobubbles in liquid, thus enhancing SDT efficiency. The stability of the nanobubbles is positively correlated with the desorption energy of the nanoparticles, which is determined by the wettability of the nanoparticles. This conclusion is verified for mesoporous silica and polystyrene nanoparticles and it is found that nanoparticles with a water contact angle of about 90° possess the largest desorption energy. To further apply this conclusion, thrombus models are constructed on rats and the experimental results demonstrate that nanoparticles with the largest desorption energy have the highest thrombolytic efficiency. It is believed that these findings will help to better understand the SDT mechanism and guide new strategies for rational design of nanoparticles adopted in SDT.

CAS / MDL: 111-30-8 102-71-6
研究领域: 生物医学工程 · 纳米技术 · 超声治疗 · 溶栓
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ULTRASONICS SONOCHEMISTRY · 2024 · IF 8.7

2D spatiotemporal passive cavitation imaging and evaluation during ultrasound thrombolysis based on diagnostic ultrasound platform

Qi Zhang,Yifei Zhu,Guofeng Zhang,Honghui Xue,Bo Ding,Juan Tu,Dong Zhang,Xiasheng Guo

Acoustic cavitation plays a critical role in various biomedical applications. However, uncontrolled cavitation can lead to undesired damage to healthy tissues. Therefore, real-time monitoring and quantitative evaluation of cavitation dynamics is essential for understanding underlying mechanisms and optimizing ultrasound treatment efficiency and safety. The current research addressed the limitations of traditionally used cavitation detection methods by developing introduced an adaptive time-division multiplexing passive cavitation imaging (PCI) system integrated into a commercial diagnostic ultrasound platform. This new method combined real-time cavitation monitoring with B-mode imaging, allowing for simultaneous visualization of treatment progress and 2D quantitative evaluation of cavitation dosage within targeted area. An improved delay-and-sum (DAS) algorithm, optimized with a minimum variance (MV) beamformer, is utilized to minimize the side lobe effect and improve the axial resolution typically associated with PCI. In additional to visualize and quantitatively assess the cavitation activities generated under varied acoustic pressures and microbubble concentrations, this system was specifically applied to perform 2D cavitation evaluation for ultrasound thrombolysis mediated by different solutions, e.g. , saline, nanodiamond (ND) and nitrogen-annealed nanodiamond (N-AND). This research aims to bridge the gap between laboratory-based research systems and real-time spatiotemporal cavitation evaluation demands in practical uses. Results indicate that this improved 2D cavitation monitoring and evaluation system could offer a useful tool for comprehensive evaluating cavitation-mediated effects ( e.g. , ultrasound thrombolysis), providing valuable insights into in-depth understanding of cavitation mechanisms and optimization of cavitation applications.

CAS / MDL: 108-78-1
研究领域: 生物医学工程 · 超声治疗 · 医学成像 · 空化动力学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。