Enzymatic approaches have become promising alternatives to chemical methods for the production of semi-synthetic β-lactam antibiotics. In this work, enzymatic synthesis of N-bromoacetyl-7-aminocephalosporanic acid (N-bromoacetyl-7-ACA), the key intermediate for the production of cefathiamidine, was reported for the first time.Of the immobilized penicillin acylases (PAs) tested, PGA-750 was the best biocatalyst. Optimization of the biocatalytic process was conducted. The optimal acyl donor, molar ratio of acyl donor to 7-ACA, pH, temperature, 7-ACA concentration, and enzyme dosage were methyl bromoacetate, 3, 7.5, 20 °C, 50 mmol/L and 4 U/mL, respectively. Under the optimal conditions, enzymatic N-acylation of 7-ACA with methyl bromoacetate afforded the desired product with the yield of 85% in 2 h, where the synthesis/hydrolysis (S/H) ratio was approximately 1.5. The immobilized enzyme PGA-750 exhibited good operational stability, and the relative yields of approximately 90% and 63% were achieved, respectively, when it was reused in 7th and 11th batch.An enzymatic approach to N-bromoacetyl-7-ACA, the key intermediate for the industrial production of cefathiamidine, has been developed successfully in a fully aqueous medium. The present work may open up a novel opportunity for the production of cefathiamidine through a simple and green process.
Xiaotong Du,Jiahao Yuan,Hongjie Cao,Li Ye,Ande Ma,Juan Du,Jialiang Pan
A novel ultrasound-assisted micellar cleanup strategy (UAMC) coupled with large volume injection (LVI) high performance liquid chromatography (HPLC) method was proposed and successfully applied to the analysis of cefathiamidine in complex biological samples such as whole blood, plasma, serum and even zebrafish, a challenging positive real sample. Based on the micelle-biomacromolecule interaction, the phase-separation feature of surfactant micelles and ultrasound cavitation, UAMC possessed an impressive matrix cleanup capability and could rapidly reach distribution equilibrium (approximately 2 min), which enabled simultaneous sample cleanup and analyte extraction within 8 min. Due to the high cleanup efficiency of UAMC, large volume of pretreated samples could be injected for analysis without peak broadening, impurity interference and column degradation. Thus, online analyte enrichment could be automatically performed to significantly improve method sensitivity by the column-switching LVI-HPLC system, a commercial HPLC system with small modifications. The UAMC-LVI-HPLC method creatively integrated sample cleanup, analyte extraction and on-column enrichment into simple operation. In addition, the UAMC-LVI-HPLC method enabled non-matrix-matched analysis of cefathiamidine in complex biological samples. This feature was helpful to address the problems caused by conventional matrix-matched or internal standard calibration methods, such as matrix bias, increased workload, limited availability of suitable blank matrices and the use of expensive internal standards. The method had low limits of detections (e.g., 0.0051 mg/L and 0.038 μg/g), wide linear ranges (0.030–100 mg/L and 0.15–489 μg/g), good linear correlation (R 2 = 0.9999), satisfactory accuracy (97.6–109.7%) and excellent intra- and interday precision (0.5–4.9%). Thus, UAMC-LVI-HPLC is expected to be a promising candidate for bioanalysis in therapeutic drug monitoring or pharmacokinetic and toxicology studies in the future.