文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

1 项目

设置提升方向
定量SERS分析
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS · 2018 · IF 2.701

Quantitative SERS analysis based on multiple-internal-standard embedded core-shell nanoparticles and spectral shape deformation quantitative theory

Xue-Qin Zhang,Sheng-Xian Li,Zeng-Ping Chen,Yao Chen,Ru-Qin Yu

Due to the practical impossibility in controlling the number and distribution of "hot spots" on or close to the surfaces of enhancing substrates, internal standards are generally used to improve the accuracy and precision of quantitative surface-enhanced Raman spectroscopy (SERS). Traditional internal standard methods based on either univariate ratiometric models or conventional multivariate calibration models can use the information of only one characteristic SERS peak of only one internal standard, which weakens the efficiency of traditional internal standard methods in improving the quantitative results of SERS assays. In this contribution, the concept of using multiple internal standards was introduced for the first time to quantitative SERS assays by incorporating a unique spectral shape deformation (SSD) quantitative theory with multiple-internal-standard embedded core-shell nanoparticles . The quantification of phosmet residues on apple skins by SERS technique with Au-core/Ag-shell nanoparticles embedded with both 2-MB and PATP as enhancing substrate was used to illustrate the applicability of the proposed strategy. Experimental results demonstrated that the proposed multiple-internal-standard strategy based on SSD achieved much more accurate and precise concentration predictions for phosmet residues on apple skin than traditional single-internal-standard methods based on either univariate ratiometric calibration models or conventional multivariate calibration models. The SERS quantitative results of the multiple-internal-standard strategy were comparable to those obtained by LC-MS/MS. The average relative deviation between the quantitative results of the proposed method and those of ICP-MS was about 8%. The good accuracy of the proposed method makes it a promising alternative for quantitative SERS assays.

研究领域: 分析化学 · 食品科学 · 纳米技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。