文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
导数技术
NEW JOURNAL OF CHEMISTRY · 2019 ·Vol. 43 ·期 46 ·18092-18097 · IF 3.069

Derivative matrix-isopotential synchronous spectrofluorimetry: a solution for the direct determination of urinary δ-aminolevulinic acid

Muhammad Ajmal,Ali Abbas Falih Shindi,Yi-Hong Liu,Yan Zhao,Ping-Ping Wu,Jia-Wen Wei,Shyamal Kr Ghorai,Shuo Hui Cao,Yao-Qun Li

δ-Aminolevulinic acid (δ-ALA) plays a vital role in the diagnosis and clinical screening of diseases like lead poisoning, hepatic porphyria, and hereditary tyrosinemia type-1. However, because of the drawbacks of the existing methods, such as tedious pre-separations and analytical interference, it poses a serious challenge for an efficient, specific, and simple δ-ALA detection strategy. In this work, matrix-isopotential synchronous fluorescence spectrometry (MISFS) and the first derivative technique are combined for the direct determination of δ-ALA in urine samples. The proposed approach promises the detection of δ-ALA in urine samples with unknown background fluorescence, alleviating complicated and tedious pre-separation processes. Here, the fluorescent derivatization of δ-ALA was based on the Hantzsch reaction. MISF spectra were scanned along a matrix-isopotential trajectory, which combines the points of equal intensity in theoretical 3D contours. The contours were constructed from the excitation and emission spectra of δ-ALA and urine. The unknown background signal of the urine was suppressed by the first order derivative technique. Maximum sensitivity and appropriate selectivity were ensured by the study of the experimental variables in the δ-ALA bands, centered at its excitation and emission maxima (392.6 nm and 464.5 nm). The limits of detection and quantification, calculated according to IUPAC definitions, were 5.4 ppb and 18 ppb, respectively. The average recoveries were 97.2% ± 2.6%. For within-run precisions, the inter-day and intra-day CVs were 5.3% and 3.6%, respectively. The results achieved by the proposed method were consistent with those obtained by the conventional HPLC-FLD method.

CAS / MDL: 123-54-6 2068-78-2
研究领域: 分析化学 · 医学诊断 · 生物化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。