JOURNAL OF HAZARDOUS MATERIALS
·
2024
·
IF 12.2
Chunyu Liu,Xingchen Zhao,Liqiong Guo,Qilin Yu,Weifei Zhang,Zijuan Peng,Yan Gao,Xiaoyun Gong,Penghui Li,Hui Jiao,Tao Zhou,Qinghe Zhang,Shanjun Song,Guibin Jiang
With increasing concerns about N-(1,3-Dimethylbutyl)-N′-phenyl-p-phenylenediamine (6PPD) and 6PPD-quinone (6PPD-Q), relevant environmental investigations and toxicological research have sprung up in recent years. However, limited information could be found for human body burden assessment. This work collected and analyzed 200 samples consisting of paired urine and plasma samples from participants (50 male and 50 female) in Tianjin, China. Low detection frequencies (DF, <15 %) were found except for urinary 6PPD-Q (86 %), which suggested the poor residue tendency of 6PPD and 6PPD-Q in blood. The low DFs also lead to no substantial association between two chemicals. Data analysis based on urinary 6PPD-Q showed a significant difference between males and females ( p < 0.05). No significant correlation was found for other demographic factors (Body Mass Index (BMI), age, drinking, and smoking). The mean values of daily excretion (ng/kg bw/day) calculated using urinary 6PPD-Q for females and males were 7.381 ng/kg bw/day (female) and 3.360 ng/kg bw/day (male), and apparently female suffered higher daily exposure. Further analysis with daily excretion and ALT (alanine aminotransferase)/TSH (thyroid stimulating hormone)/ blood cell analysis indicators found a potential correlation with 6PPD-Q daily excretion and liver/immune functions. Considering this preliminary assessment, systematic research targeting the potential organs at relevant concentrations is required.
研究领域:
环境科学
·
毒理学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ANALYTICAL SCIENCES
·
2021
·Vol. 37
·期 2
·315-320
·
IF 2.081
Siqingaowa HAN,Chen ZHANG,Zhijie CHEN,Xuanyu SHA,Wuliji HASI
This paper describes a method based on surface enhanced Raman spectroscopy (SERS) technology for rapid detection of dezocine in urine and serum. Firstly, an Ag colloid substrate was prepared and characterized. Then the Raman characteristic peaks of dezocine were assigned from both theoretical and experimental aspects. Finally, the Raman peak at 661 cm−1 was selected as its characteristic peak to perform SERS detection on dezocine in urine and serum, and the detection limits of dezocine in urine and serum were determined. The relationships between the characteristic peak intensity and the concentration of dezocine in urine and serum were fitted and the recovery rates were calculated. This rapid, accurate and non-destructive method establishes a good foundation for rapid on-site detection of dezocine in biological samples.
研究领域:
分析化学
·
生物医学工程
·
药物分析
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY
·
2024
·Vol. 333
·期 3
·1357-1365
·
IF 1.5
Mei Lingzi,Shao Hui,Cui Lingzhi,Yang Jinmin,Zhang Lei
A novel method for rapid radioanalytical measurement of uranium and plutonium in 100ml emergency urine samples was developed, through optimized selection of the separation and purification process and a combined measurement with ICP-TOF-MS and alpha spectrometry. The typical analytical time is within 6 h, the recovery rates are more than 80%, and the minimum detection activity concentrations are 3.4 × 10 −4 Bq/L for 238 U and 2.5 × 10 −3 Bq/L for 239 Pu respectively. The spiked test shows that this method can be used for quantitative evaluation of the activity concentration of 238 U and 239 Pu in urine samples accurately.
研究领域:
放射化学
·
环境科学
·
医学检测
✓ 已验证
DOI
高影响因子
MICROCHEMICAL JOURNAL
·
2024
·
IF 4.9
Haiqin Li,Yueyue Li,Xiaoliang Zhang,Xiaojun Ren,Xiaochun Li
As a non-invasive monitoring method, urine analysis is one of the “three routines” of medical examination, which is of great significance for the early diagnosis, therapeutic effect judgment and long-term fine monitoring of chronic diseases such as metabolic system diseases and kidney diseases. It is imperative to develop a home urine routine detection system. In this paper, Smart Urine Analyzer is innovatively developed by combining smartphones with array urine dipsticks, and equipped with the unique design of adjustable bracket suitable for camera position of different smartphones. The optimal colorimetric value was selected for analysis based on chromogenic response characteristics combined with digital image colorimetry, and the breakthrough from qualitative semi-quantification to precise quantification of 9 kinds of urine biomarkers was completed. And a smartphone App for automated image recognition and processing was developed, which was applied for at-home routine healthcare. 100 clinical urine samples were used to evaluate the reliability of the system. Among them, the ROC curve showed a high consistency between Smart Urine Analyzer and the Dirui H-800 urine analyzer in hospital, which further verified the practicability. As a result, the user-friendly Smart Urine Analyzer can share health data and condition with doctors in real time, which provides a new scheme and means for the home detection of urine biomarkers, and has great practical application value as a potential home medical service assistant.
研究领域:
医学诊断
·
泌尿学
·
医疗技术
·
移动健康(mHealth)
·
临床化学
✓ 已验证
产品关联
DOI
高影响因子
BIOLOGICAL TRACE ELEMENT RESEARCH
·
2016
·Vol. 175
·期 2
·298-305
·
IF 1.798
Li Yan,Yu Hua,Li Peng,Bian Ying
In order to assess occupational exposure level of 15 rare earth elements (REEs) and identify the associated influence, we used inductively coupled plasma mass spectrometry (ICP-MS) based on closed-vessel microwave-assisted wet digestion procedure to determinate the concentration of Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in urinary samples obtained from workers producing ultrafine and nanoparticles containing cerium and lanthanum oxide. The results suggest that La and Ce were the primary component, together accounting for 97 % of total REEs in workers. The urinary levels of La, and Ce among the workers (6.36, 15.32 μg.g −1 creatinine, respectively) were significantly enriched compared to those levels measured in the control subjects (1.52, 4.04 μg.g −1 creatinine, respectively) ( p < 0.05). This study simultaneously identified the associated individual factors, the results indicate that the concentrations in over 5 years group (11.64 ± 10.93 for La, 27.83 ± 24.38 for Ce) were significantly elevated compared to 1–5 years group (2.58 ± 1.51 for La, 6.87 ± 3.90 for Ce) ( p < 0.05). Compared the urinary levels of La and Ce at the separation and packaging locations (9.10 ± 9.51 for La, 22.29 ± 21.01 for Ce) with the other locations (2.85 ± 0.98 for La, 6.37 ± 2.12 for Ce), the results show urinary concentrations were significantly higher in workers at separation and packaging locations ( p < 0.01). Inter-individual variation in levels of La and Ce in urine is the result of multi-factorial comprehensive action. Further researches should focus on the multiple factors contributing to the REEs levels of the occupationally exposed workers.
研究领域:
职业健康
·
分析化学
·
环境医学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY
·
2020
·
IF 4.192
Jialing Min,Zitong Wang,Chenglin Liang,Wenjie Li,Jie Shao,Kunrui Zhu,Lu Zhou,Jing Cheng,Shihong Luo,Lehan Yu,Yudong Wu,Mingyong Xie,Xiaojuan Hu
To date, there has been limited information on phytoestrogen (PE) exposure and metabolism in breastfed infants. In the present work, 50 sample pairs of Chinese breastfed infants’ urine and the corresponding breast milk were collected. The contents of the relevant PE metabolites in the biosamples were detected via liquid chromatography–tandem mass spectrometry. The correlations between the PE metabolite contents in breastfed infants’ urine and those in the corresponding breast milk were analyzed. The average concentrations of total PE metabolites in breast milk and urine were 0.27 and 0.23 nmol/mL, respectively. Genistein and enterolactone levels in the infant urine were positively correlated with their concentrations in the corresponding breast milk samples, which implies that urine excretion can be utilized as a noninvasive parameter for precise genistein and enterolactone intake assessment. Additionally, the efficiency of PE urine excretion showed significant differences across infants with different ages, genders, and durations of pregnancy.
研究领域:
营养学
·
分析化学
·
儿科医学
✓ 已验证
DOI
PubMed
高影响因子
BIOMEDICAL CHROMATOGRAPHY
·
2024
·Vol. 38
·期 6
·e5866
·
IF 1.8
Zhijian Zha,Ruihua Wang,Qian Wang,Fahui Chen,Ziyang Ye,Yafeng Li
Immunoglobulin nephropathy (IgAN) stands as the most prevalent primary glomerular nephropathy globally, typically diagnosed through an invasive renal biopsy. Emerging research suggests the significant involvement of chiral amino acids in kidney disease progression. This study introduces a nonderivative LC–tandem mass spectrometry approach, offering efficient separation outcomes within 15 min for identifying chiral amino acids in human urine samples. Subsequently, using this method, the analysis of l - and d -amino acids in the urine of both patients with IgAN and healthy individuals was conducted. Fourteen d -amino acids and 20 l -amino acids were identified in the urine samples obtained from 17 patients with IgAN and 21 healthy individuals. The results indicated notable variances in the concentrations of both l - and d -amino acids between the IgAN and healthy control groups. In contrast to the healthy group, the IgAN group exhibited higher mean urine concentrations of most l -amino acids and lower concentrations of d -amino acids. Furthermore, correlations between amino acids and clinical markers were investigated. These results propose a novel method for monitoring trace amino acids in urine samples and introduce a new concept for potential markers of IgAN.
研究领域:
医学
·
分析化学
·
肾脏病学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Photonics
·
2022
·Vol. 9
·期 10
·784
·
IF 2.536
Zixin Yang,Gaozhe Cai,Jianlong Zhao,Shilun Feng
Urine examinations are widely applied in hospitals using urine test strip analyzers or other sophisticated professional instruments. However, such methods are inconvenient health monitoring of patients at home. Herein, we construct an optical device for point-of-care testing (POCT) for urine analysis at home or on the spot. A black box and color calibration curve are established to eliminate the influence of ambient light with an independent internal lighting system included in the device. A Raspberry Pi with a CSI camera is programmed to automatically collect the strip images and identify the HSV values of the image with an image processing algorithm. During this process, these corrected colors are converted to concentration values by preloaded standard curves. Under optimal conditions, the proposed POCT device can quantitatively and automatically detect glucose within 1 min, with linear detection ranging from 2 mM to 60 mM and a detection limit of 1.16 mM. In addition, the device demonstrates satisfactory accuracy and quantitative analysis of ketone bodies, glucose, protein, occult blood, pH, and leukocytes in human urine samples with high-resolution concentrations, achieving results similar to those obtained with hospital instruments. The proposed device is portable and user-friendly, providing convenient colorimetric analysis for urine. Furthermore, the proposed device also has considerable potential for the development of in vitro diagnosis methods through combination with other test strips.Keywords:colorimetry detection;HSV parameters;point-of-care testing;urine test
研究领域:
医学诊断
·
生物工程
✓ 已验证
产品关联
DOI
高影响因子
Forensic Toxicology
·
2016
·Vol. 34
·期 2
·398-402
·
IF 0
Shintani-Ishida Kaori,Kakiuchi Yasuhiro,Ikegaya Hiroshi
The toxicological detection of the new synthetic cathinone 4′-methyl-α-pyrrolidinohexanophenone (MPHP) in urine samples has been impossible, because much of MPHP is metabolized before its excretion into urine. In this study, we successfully quantified unmetabolized MPHP in urine of an autopsy case using a sensitive method by liquid chromatography–time-of-flight-mass spectrometry. The quantification method showed good linearity in the range of 1.00–100 ng/mL, and the limit of detection was 0.5 ng/mL in human urine. In the autopsy case, the concentrations of MPHP in urine, plasma, and liver tissue samples were determined to be 60.1, 32.9 ng/mL, and 63.1 ng/g, respectively.
研究领域:
法医学
·
分析化学
·
毒理学
✓ 已验证
DOI
PubMed
MICROCHIMICA ACTA
·
2013
·Vol. 180
·期 5
·453-460
·
IF 3.434
Du Fangkai,Zeng Fang,Ming Yunhao,Wu Shuizhu
We report on a simple method for the determination of iodide in aqueous solution by exploiting the fluorescence enhancement that is observed if the complex formed between carbon dots and mercury ion is exposed to iodide. Fluorescent carbon dots (C-dots) were treated with Hg(II) ion which causes quenching of the emission of the C-dots. On addition of iodide, the Hg(II) ions are removed from the complex due to the strong interaction between Hg(II) and iodide. This causes the fluorescence to be restored and enables iodide to be determined in the 0.5 to 20 μM concentration range and with a detection limit of ~430 nM. The test is highly selective for iodide (over common other anions) and was used for the determination of iodide in urine.
A“turn-on” fluorescent probe based on carbon dots was obtained and using it to determine the concentration of iodide according to the fluorescent enhancement in aqueous solution
研究领域:
分析化学
·
环境科学
✓ 已验证
DOI
高影响因子
JOURNAL OF ENVIRONMENTAL MANAGEMENT
·
2024
·
IF 8
Tian Zhang,Wenlong Zhang,Peizhe Sun
Nitrogen, phosphorus and potassium are essential for crop growth, which are abundant in urine. Although numerous studies have developed techniques to recover ammonium and phosphorus from urine, limited research made efforts on the recovery of potassium, which is a non-renewable resource with uneven global distribution. In this study, we explored the possibility of zeolite based mixed matrix membranes (MMMs) to selectively recover ammonium and potassium from urine, with minimal detention of sodium. The findings demonstrated that upon the pre-treatment of zeolites with sodium chloride solution, a 70 wt% zeolite loaded MMM could achieve 69.3 % recovery of potassium and almost full recovery of ammonium. By varying the desorption temperatures and MMMs production process, it was discovered that stepwise backwash at low temperature (276 K) greatly lowered sodium recovery whilst simultaneously enhancing the recovery of potassium and ammonium. This study demonstrates the potential of recovering potassium and ammonium from urine using zeolite-loaded MMMs, coupled with achieving low-sodium recovery.
研究领域:
环境工程
·
废水处理
·
资源回收
✓ 已验证
产品关联
DOI
PubMed
高影响因子
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
·
2025
·
IF 4.6
Xiaoli Zhang,Zhaoguang Wang,Jing Yang,Yingying Li,Cheng Lu,Yanqiang Hao,Guanbo He,Yongjian Zhang,Qifang Song,Jun Long,Jiajie Liang,Yong Tang
Currently, producing NPSH after HPV infection of cells has been confirmed. These NPSH-containing substances accumulate around the urethral opening and are subsequently washed out with urine. Therefore, indirect detection of HPV infection by assessing NPSH levels in urine is feasible, but it has not been reported in detail so far. Here, an assay using phosphotungstic acid to oxidise and produce colour changes by NPSH in urine was developed. This assay enabled the rapid, non-invasive identification of HPV infection by detecting the metabolic byproduct NPSH produced by HPV-infected cells. Employing a smartphone-based device, developed using an ambient light sensor, reduces the cost and simplifies the operation associated with the colourimetric assay. The colourimetric assay was used to detect L-cysteine and L-ascorbic acid standard substance (as NPSH mimics), the limited of detection were 0.12 mM and 31.25 μM, respectively, with high reproducibility and stability. When this colourimetric assay was used to evaluate urine samples from individuals suspected of HPV infection, along with other at-home self-screening methods for HPV nucleic acid detection in urine, showed comparable sensitivity and specificity. Compared with nucleic acid detection in urine, this colourimetric assay is cost-effective, user-friendly, amenable to self-sampling, and enables testing at one’s convenience and location of choice, which is more suitable for home self-testing or population self-screening.
研究领域:
医学检验
·
生物化学
✓ 已验证
产品关联
DOI
PubMed
高影响因子