文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
局部pH值
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2024 · IF 4.1

In-situ fabrication of tungsten oxide film pH micro-sensor and its application on the pH monitoring of Fe-Cu galvanic corrosion

Yu-Hua Xiao,Qiu-Yu Huang,Jian Wang,Xin-Ran Li,Ze-Jie Zhu,Qin-Hao Zhang,Fa-He Cao

Localized and interface pH values are important parameters for studying the corrosion progress and complex interface reactions. Although commercial glass pH sensors have been widely used to measure solution pH value due to their advantages of long stability and high sensitivity, they were unable to determine the interface and microregion pH value for their difficulty in miniaturization. In this work, an all-solid-state pH micro-sensor with strong adhesion strength was in-situ fabricated on diameter 15 μm tungsten ultramicroelectrode (UME) using constant current anodizing. The pH micro-sensor showed good linear response (R 2  = 0.999), excellent sensitivity (with a slope of −53.8 mV/pH), quick response (<0.1 s), long lifetime (>44 days) and great anti-interference ability to most of the ions in marine (selectivity coefficients pK ij  > 7), such as SO 4 2− , Cl − , NO 3 − , K + , Mg 2+ and Fe 2+ . Then, the pH micro-sensor, combined with the potentiometric mode of SECM, was further employed to explore the localized pH value distribution during the galvanic corrosion of Fe-Cu couple in 0.1 M NaCl solution. To further verify the anti-interference ability of pH micro-sensor, potentiometric SECM experiment was also conducted in artificial seawater. Results showed that both acidic sites and alkalizing sites appeared on the Fe surface, while homogeneous alkalization took place overall Cu surface. This was consistent with the SVET results that anodic and cathodic areas existed simultaneously on Fe surface. Thus, it could be concluded that local corrosion occurred on Fe surface and only part of the Fe surface acted as the anodic even under galvanic effect. However, Cu acted as cathode with the homogeneously distributing cathodic current on the whole surface during the galvanic corrosion.

研究领域: 材料科学 · 电化学 · 腐蚀科学 · 传感器与执行器 · 环境监测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。