文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

7 项

设置提升方向
屈光手术
Diagnostics · 2021 ·Vol. 11 ·期 8 ·1466 · IF 3.706

Current Developments in Corneal Topography and Tomography

Piotr Kanclerz,Ramin Khoramnia,Xiaogang Wang

Introduction: Accurate assessment of the corneal shape is important in cataract and refractive surgery, both in screening of candidates as well as for analyzing postoperative outcomes. Although corneal topography and tomography are widely used, it is common that these technologies are confused. The aim of this study was to present the current developments of these technologies and particularly distinguish between corneal topography and tomography. Methods: The PubMed, Web of Science and Embase databases were the main resources used to investigate the medical literature. The following

研究领域: 眼科学 · 屈光外科学 · 影像学 · 生物医学工程 · 临床诊断学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Photodiagnosis and Photodynamic Therapy · 2024 · IF 3.1

Assessment of the variability and correlation of biometric measurements in eyes with cataracts

Jian-Feng Zhao,Chen Yang,Jie Zhou,Hai-Yan Zhang,Yu Geng

Purpose To assess the variability and correlation of ocular biometric parameters in eyes with cataracts and examine their association with age and gender. Methods A retrospective analysis was performed on biometric data from 7,458 eyes without retinal pathologies, using an optical biometer equipped with low-coherence reflectometry technology. Pearson's correlation coefficients (r) were used to evaluate the relationships between age, gender, and various ocular parameters, including axial length (AL), anterior chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT), corneal refractive power (Km), and white-to-white (WTW) measurement. Results The mean AL was 23.82 ± 1.83 mm (SD). Among the study cohort, 8.0 % (593 eyes) were categorized as having short AL (AL ≤ 22 mm), 60.5 % (4,520 eyes) as having normal AL (22 mm < AL ≤ 24 mm), 21.2 % (1,579 eyes) as having long AL (24 mm < AL ≤ 26 mm), and 10.3 % (766 eyes) as having a AL (> 26 mm). The mean age of the cohort was 64.18 ± 14.95 years (range: 18 - 98 years), with males averaging 56.53 ± 13.88 years and females averaging 72.19 ± 11.41 years. Mean values for ACD, LT, Km, CCT, WTW, and angle kappa were found to vary with both age and gender. Males demonstrated significantly longer AL, deeper ACD, thicker LT, larger WTW, and lower Km compared to females ( P < 0.05). Although males exhibited a greater anterior segment length (ASL), this difference did not reach statistical significance ( P > 0.05). No significant correlation was found between ACD and AL in the short and long AL groups, while a positive correlation was observed in the normal and long AL groups. Additionally, LT demonstrated a negative correlation with AL in the normal AL group but a positive correlation in the long AL group. Conclusions Cataracts develop at a greater age in female patients than in males. Ocular biometric parameters, including ACD, LT, CCT, Km, and (WTW) measurement, are influenced by age and gender. Lens thickness is the primary factor affecting ACD, though CCT, Km, and WTW also play significant roles. Furthermore, a negative correlation between AL and LT was identified, with variations depending on AL classification.

研究领域: 眼科 · 生物医学工程 · 临床研究 · 老年医学 · 屈光手术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Eye and Vision · 2021 ·Vol. 8 ·期 1 ·22 · IF 3.257

Lens thickness and associated ocular biometric factors among cataract patients in Shanghai

Meng Jiaqi,Wei Ling,He Wenwen,Qi Jiao,Lu Yi,Zhu Xiangjia

Background To evaluate the distribution of lens thickness (LT) and its associations with other ocular biometric factors among cataract patients in Shanghai. Methods Twenty-four thousand thirteen eyes from 24,013 cataract patients were retrospectively included. Ocular biometric factors including LT, central corneal thickness (CCT), anterior chamber depth (ACD), white-to-white (WTW) distance, anterior corneal curvature, and axial length (AL) were obtained using the IOLMaster700. The associations between LT and general or ocular factors were assessed. Results The mean age was 62.5 ± 13.6 years and 56.1% were female. The mean LT was 4.51 ± 0.46 mm. The LT was greater in older patients ( P  < 0.001). LT was positively correlated with CCT, while negatively correlated with ACD, WTW, and anterior corneal curvature ( P  < 0.001). Multivariate analysis revealed that increased LT was associated with older age, male gender, thicker CCT, shallower ACD, larger WTW, and flatter anterior corneal curvature ( P  < 0.001). LT changed with a variable behavior according to AL. In short eyes LT increased as AL increased, then decreased with longer AL in normal eyes and moderate myopic eyes, but increased again as AL increased in highly myopic eyes. Thickest LT was found in the 20.01–22 mm AL group. The correlation between LT and other biometric factors remained significant when stratified by ALs. Conclusions In a large Chinese cataractous population, we found that the thicker lens may be associated with older age, male gender, thicker CCT, shallower ACD, larger WTW, and flatter anterior corneal curvature. As AL increased, the change of LT was nonlinear, with the thickest lens seen in the 20–22 mm AL group.

研究领域: 眼科 · 生物医学工程 · 临床眼科学 · 屈光手术 · 白内障研究
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Eye and Vision · 2021 ·Vol. 8 ·期 1 ·9 · IF 3.257

Unintended changes in ocular biometric parameters during a 6-month follow-up period after FS-LASIK and SMILE

Wang Junjie,Lopes Bernardo T.,Li Hechen,Vinciguerra Riccardo,Cao Si,Wu Songan,Zhu Rong,Wang Qinmei,Zheng Xiaobo,Bao Fangjun,Elsheikh Ahmed

Background Corneal refractive surgery has become reliable for correcting refractive errors, but it can induce unintended ocular changes that alter refractive outcomes. This study is to evaluate the unintended changes in ocular biometric parameters over a 6-month follow-up period after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE). Methods 156 consecutive myopic patients scheduled for FS-LASIK and SMILE were included in this study. Central corneal thickness (CCT), mean curvature of the corneal posterior surface (K pm ), internal anterior chamber depth (IACD) and the length from corneal endothelium to retina (ER) were evaluated before and after surgery over a 6-month period. Results Both the FS-LASIK and SMILE groups (closely matched at the pre-surgery stage) experienced flatter K pm , shallower IACD and decreased ER 1 week post-surgery ( P  < 0.01), and these changes were larger in FS-LASIK than in SMILE group. During the 1 week to 6 months follow up period, K pm , IACD and ER remained stable unlike CCT which increased significantly ( P  < 0.05), more in the FS-LASIK group. Conclusions During the follow up, the posterior corneal surface became flatter and shifted posteriorly, the anterior chamber depth and the length from the corneal endothelium to retina decreased significantly compared with the pre-surgery stage. These unintended changes in ocular biometric parameters were greater in patients undergoing FS-LASIK than SMILE. The changes present clear challenges for IOL power calculations and should be considered to avoid affecting the outcome of cataract surgery.

研究领域: 眼科学 · 屈光手术 · 生物测量 · 临床研究
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Scientific Reports · 2021 ·Vol. 11 ·期 1 ·983 · IF 4.38

Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices

Schiano-Lomoriello Domenico,Hoffer Kenneth J.,Abicca Irene,Savini Giacomo

We assess repeatability of automatic measurements of a new anterior segment optical coherence tomographer and biometer (ANTERION) and their agreement with those provided by an anterior segment-optical coherence tomography device combined with Placido-disk corneal topography (MS-39) and a validated optical biometer (IOLMaster 500). A consecutive series of patients underwent three measurements with ANTERION and one with MS-39. A subgroup of patients underwent biometry also with IOLMaster 500. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (COV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. Paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. Repeatability of ANTERION measurements was high, with ICC > 0.98 for all parameters except astigmatism (0.963); all parameters apart from those related to astigmatism revealed a COV < 1%. Repeatability of astigmatism improved when only eyes whose keratometric astigmatism was higher than 1.0 D were investigated. Most measurements by ANTERION and MS-39 showed good agreement. No significant differences were found between measurements by ANTERION and IOLMaster, but for corneal diameter. ANTERION revealed high repeatability of automatic measurements and good agreement with both MS-39 and IOLMaster for most parameters.

研究领域: 眼科学 · 生物医学成像 · 临床测量 · 屈光手术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Annals of Translational Medicine · 2020 ·Vol. 8 ·期 22 ·1553 · IF 3.297

Recent developments in intraocular lens power calculation methods—update 2020

Giacomo Savini,Leonardo Taroni,Kenneth J Hoffer

For many decades only a few formulas have been available to calculate the intraocular lens (IOL) power for patients undergoing cataract surgery: the Haigis, Hoffer Q, Holladay 1 and 2 and SRK/T. In recent years, several new formulas for IOL power calculation have been introduced with the aim of improving the accuracy of refraction prediction in eyes undergoing cataract surgery. These include the Barrett Universal II, the Emmetropia Verifying Optical (EVO), the Kane, the Næser 2, the Olsen, the Panacea, the Pearl DGS, the Radial Basis Function (RBF), the T2 and the VRF formulas. Although most of them are unpublished so that their structure is unknown, we give an overview of each formula and report the results of the studies that have compared them. Their performance in short and long eyes is provided and a special focus is given on the issue of segmented axial length, which is a promising method to obtain more accurate outcomes in short and long eyes. Here, the group refractive index originally developed for the IOLMaster may not represent the best method to convert the optical path length into a physical distance. The issue of posterior and total corneal astigmatism (TCA) is discussed in relation to toric IOLs; the latest formulas for toric IOLs and their results are also reported.

研究领域: 眼科学 · 白内障手术 · 屈光手术 · 生物测量 · 光学设计 · 临床预测模型
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
PLoS One · 2018 ·Vol. 13 ·期 2 ·e0193023 · IF 2.766

Precision (repeatability and reproducibility) of ocular parameters obtained by the Tomey OA-2000 biometer compared to the IOLMaster in healthy eyes

Yanjun Hua,Wei Qiu,Qiuyi Xiao,Qiang Wu

Purpose To assess the precision (repeatability and reproducibility) of ocular parameters measured by the Tomey OA-2000 biometer, and to compare them with those measured by the IOLMaster. Methods In this prospective study, the right eyes of 108 healthy subjects were included. Three consecutive scans were obtained by 2 observers using the Tomey OA-2000, and in the same session one observer used the IOLMaster (version 5.4.4.0006) for the measurements. About 1 week later, 3 scans were obtained by one observer using the Tomey OA-2000. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), keratometer readings, pupil diameter (PD) and corneal diameter (CD) values measured by the Tomey OA-2000 and IOLMaster were analyzed. The coefficient of variation (CoV), intraclass correlation coefficient (ICC), within subject standard deviation (Sw) and 2.77Sw were calculated to assess the repeatability and reproducibility. The paired t test and Bland-Altman plots were used to analyze the differences and agreements of parameters measured by the two devices, respectively. Results Intraobserver repeatability, and interobserver and intersession reproducibility of the AL, CCT, ACD, LT, Kf, Ks, Km, PD and CD values measured by the Tomey OA-2000 biometer showed a CoV of less than 1% except that for PD, and an ICC of more than 0.97 except that for PD and CD. The AL, Kf, Ks, Km and CD values measured by the Tomey OA-2000 were 0.058 ± 0.094 mm, 0.088± 0.150 diopters (D), 0.163 ± 0.170 D, 0.127 ± 0.117 D and 0.171 ± 0.217 mm lower than those measured by the IOLMaster, respectively (all Ps < 0.05). However, the ACD values from the two devices were comparable (P = 0.169). The 95% linite of agreement (LoA) of the AL, ACD, CD and all keratometer readings were no more than 0.24 mm, 0.14 mm 0.60 mm and 0.5 D, respectively. Conclusion Except for the PD and CD, the ocular parameters measured by the Tomey OA-2000 were highly repeatable and reproducible. Except for the CD value, there was good agreement of ocular parameters measured by the Tomey OA-2000 and the IOLMaster in healthy eyes.

研究领域: 眼科学 · 生物医学测量 · 屈光手术 · 白内障手术 · 光学生物测量
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。