文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

4 项

设置提升方向
工质对
JOURNAL OF CHEMICAL AND ENGINEERING DATA · 2019 · IF 2.298

Isothermal Vapor–Liquid Equilibrium of the Absorption Working Pairs (HFC-32 + DMETrEG, HFC-32 + NMP) at Temperatures from 293.15 to 343.15 K

Yibo Fang,Zanjun Gao,Kangli Bao,Jiongliang Huang,Xiaosheng Ji,Xiaohong Han,Guangming Chen

The working pairs of HFCs + organic absorption solvents are commonly used in absorption systems. In this work, the vapor–liquid equilibrium (VLE) data of HFC-32 + DMETrEG at (293.15–343.15) K and HFC-32 + NMP at (323.15–343.15) K were measured in a dual cycle apparatus. The VLE data were correlated by Antione-type equation, NRTL, and PR + MHV1 + NRTL model, respectively. The predicted VLE data showed a good agreement with the experimental VLE data. NRTL model was recommended to predict the VLE data and characteristic of solution for HFC-32 + DMETrEG and HFC-32 + NMP, compared to PR + MHV1 + NRTL model. The comparison of VLE characteristics for five binary mixtures (HFC-32 + DMETrEG, HFC-32 + NMP, HFC-32 + DMF, HFC-32 + DMAC, and HFC-32 + DMEDEG) was carried out. The compared results showed that the system pressures of HFC-32 + DMETrEG and HFC-32 + NMP were lower than other three mixtures, and the negative deviations from Raoult’s law of HFC-32 + DMETrEG and HFC-32 + NMP were larger than the others, which indicated that the two mixtures were more suitable as the working fluids for absorption system.

CAS / MDL: 872-50-4
研究领域: 化学工程 · 热力学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ENERGY · 2023 · IF 9

Cooling performance of compression-absorption cascade system with novel ternary ionic-liquid working pair

Qiang Ji,Yikai Wang,Yonggao Yin,Mu Wang,Chunwen Che,Bowen Cao,Wanhe Chen

The compression-absorption cascade system (CACS) is an efficient way to use waste heat or renewable energy. However, most of the current studies are all based on heating scenarios, and the cooling characteristics of CACS have not been reported. In terms of absorption working pairs, ionic liquids (ILs) have great potential to become alternative working fluids for absorption systems , but one of the factors restricting the large-scale application is their high price. Seeking effective strategies to reduce economic constraints while ensuring the excellent performance of IL working pairs will become a hot topic in the future. In order to overcome the application limit of ILs, a feasible strategy is proposed which the relatively cheap salt is used to replace part of the expensive IL and they are employed together as the absorbent. In this work, the vapor-liquid equilibrium data of novel IL working fluid LiBr/[EMIM][OAC]/H 2 O is measured experimentally, and the cooling performance of CACS with the proposed working pair is analyzed. The results show that the cooling efficiency of CACS is 0.738–0.849, which is commonly higher than traditional absorption chillers. As for comparing with reference working fluids, the novel working pair can improve the maximum performance by 1.80%–46.81%. In addition, the crystallization problem can be overcome to some extent compared with LiBr/H 2 O under the same absorption ability, and as for comparing with [EMIM][OAC]/H 2 O, the economic limitation can be alleviated. This work can be used to ease the economic limit of ILs due to the immature market right now, and give a reference for seeking a satisfactory cooling method of buildings in the context of carbon neutrality.

CAS / MDL: 7550-35-8
研究领域: 能源工程 · 制冷技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
International Journal of Refrigeration · 2025 · IF 3.8

Thermodynamic investigation of ternary ionic liquid working pairs and application in absorption heat transformers

Yutong Gong,Feng Liu,Jun Sui,Yanlong Lv,Yuhao Wang

To explore the application performance of ternary ionic liquid-based working pairs in absorption heat transformers, this study measured the saturated vapor pressure of H 2 O/LiBr+[EMIM][Ac], H 2 O/LiBr+[BMIM][I], and H 2 O/LiBr+[EPy][Br] solutions at temperature ranging from 25 to 200°C under different concentrations. The experimental data were correlated with an absorption heat exchanger model using the Non-Random Two-Liquid (NRTL) activity coefficient model and enthalpy calculation equations. Sensitivity analyses were conducted on condensation, evaporation/generation, and absorption temperature, with comparisons made to the conventional LiBr/H 2 O working pair. The results demonstrated that the traditional LiBr/H 2 O solution exhibited higher coefficients of performance (COP) and exergetic efficiency (ECOP) under varying condensation, evaporation, and absorption temperatures, but its applicable heat source temperature range was narrow, and it showed no advantage under high output temperature requirements. In contrast, the three ternary IL working pairs exhibited lower COP and ECOP values compared to LiBr/H 2 O, but H 2 O/LiBr+[BMIM][I] and H 2 O/LiBr+[EPy][Br] demonstrated broader applicable heat source and output temperature ranges. Among them, H 2 O/LiBr+[BMIM][I] exhibited the best performance, achieving superior system efficiency at heat source temperatures above 102°C, making it suitable for systems operating with unstable waste heat sources. Additionally, H 2 O/LiBr+[BMIM][I] achieved the highest optimal ECOP of 0.58 at an absorption temperature of 215°C, meeting high output temperature demands and offering significant temperature lift advantages. This study provides critical insights for the application of ternary ionic liquid working pairs in absorption heat transformers. Future research could incorporate system structure optimization and environmental-economic analysis to provide stronger scientific foundations for the application of ternary ionic liquid working pairs.

研究领域: 化学工程 · 热力学 · 能源系统 · 传热学 · 离子液体 · 制冷与空调
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHEMICAL AND ENGINEERING DATA · 2021 · IF 2.694

Isothermal Vapor–Liquid Equilibria of the Absorption Working Pairs (R1234ze(E) + NMP and R1234ze(E) + DMETrEG) at Temperatures from 293.15 to 353.15 K

Gongran Ye,Yibo Fang,Yalun Li,Zhikai Guo,Lin Wang,Xiaohong Han

The absorption refrigeration system (ARS) was important for energy saving, which can be driven by low-grade energy. In this work, the mixtures of trans-1,3,3,3-tetrafluoropropene (R1234ze(E)) + N-methyl-2-pyrrolidone (NMP) and R1234ze(E) + triethylene glycol dimethyl ether (DMETrEG) were considered as the promising new working fluids for ARS. The vapor–liquid equilibrium (VLE) data of R1234ze(E) + DMETrEG and R1234ze(E) + NMP binary mixtures were measured using a liquid-recirculation apparatus from 293.15 to 353.15 K. The VLE data were correlated by the five-parameter non-random two-liquid activity coefficient model, and the correlated results showed a good agreement with the experimental VLE data. The average absolute relative deviation and maximum absolute relative deviation of the pressure were 1.70 and 5.11% for R1234ze(E) + NMP and 1.30 and 3.22% for R1234ze(E) + DMETrEG, respectively. The two binary mixtures exhibited positive deviations from Raoult’s law.

CAS / MDL: 872-50-4
研究领域: 热力学 · 化学工程 · 制冷技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。