文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
带分散
PROCESS BIOCHEMISTRY · 2013 · IF 2.414

Two-stage recovery of S-adenosylmethionine using supported liquid membranes with strip dispersion

Yuxiang Tang,Wei Liu,Jiangling Wan,Yuanxin Wang,Xiangliang Yang

We report the selective recovery of S-adenosylmethionine (SAM) from fermentation broths using a two-stage supported liquid membrane system with strip dispersion (SLM-SD). The system utilized two MiniModule ® hollow-fiber membrane modules as microporous supports and an organic membrane solution consisting of the extractants of sodium di-2-ethylhexyl sulfosuccinate (AOT), di-(2-ethylhexyl)phosphoric acid (DEHPA), and trioctylphosphine oxide (TOPO) in the solvent n-octanol. SAM was extracted in the first membrane module. Methionine (Met) was captured by the first stripping solution and further purified in the second membrane module. pH values in the feed phase and the first and second stripping solutions, extractant concentrations, NaCl concentration, and the SAM acceptor in the first stripping solution were optimized. Strip dispersion mixing speed, pressure differences across the membranes, and flow rates of the feed and strip dispersion phases were investigated experimentally. The optimal extractant concentrations were: AOT 2.78   wt%, DEHPA 27.0   wt%, and TOPO 1.61   wt%. The optimal pH values in the feed phase and the first and second stripping solution were 3.0, 2.5, and 1.0, respectively. SAM extraction efficiency of 98.7%, SAM recovery efficiency of 91.8% and Met removal efficiency of 85.4% were achieved within 5   h. Finally, the mass transfer analysis indicated that the mass transfer resistances from the extraction reaction and the membrane phase were predominant.

研究领域: 生物工程 · 化学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2021 · IF 6.986

Gel Electrophoresis Chip Using Joule Heat Self-Dissipation, Short Run Time, and Online Dynamic Imaging

Jingjing Xue,Qiang Zhang,Jun Cao,Youli Tian,Genhan Zha,Xiaoping Liu,Weiwen Liu,Yuxing Wang,Dingkun Gui,Chengxi Cao

Gel electrophoresis (GE) is one of the most general tools in biomedicine. However, it suffers from low resolution, and its mechanism has not been fully revealed yet. Herein, we presented the dispersion model of w2 (t) ∝ Tt, showing the band dispersion (w) via temperature (T) and running time (t) control. Second, we designed an efficient GE chip via the time control and rapid Joule heat self-dissipation by thermal conductive plastic (TCP) and electrode buffer. Third, we conducted the simulations on TCP and polymethylmethacrylate (PMMA) chips, unveiling that (i) the temperature of TCP was lower than the PMMA one, (ii) the temperature uniformity of TCP was better than the PMMA one, and (iii) the resolution of TCP was superior to the PMMA one. Fourth, we designed both TCP and PMMA chips for experimentally validating the dispersion model, TCP chip, and simulations. Finally, we applied the TCP chip to thalassemia and model urine protein assays. The TCP chip has merits of high resolution, rapid run of 6–10 min, and low cost. This work paves the way for greatly improving electrophoretic techniques in gel, chip, and capillary via temperature and time control for biologic study, biopharma quality control, clinical diagnosis, and so on.

研究领域: 生物医学工程 · 分析化学 · 生物技术
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。