文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数17个

设置提升方向
微柱阵列
SENSORS AND ACTUATORS B-CHEMICAL · 2017 · IF 5.401

Highly enhanced sensitivity of optical oxygen sensors using microstructured PtTFPP/PDMS-pillar arrays sensing layer

Yongyun Mao,Yibo Gao,Shanshan Wu,Siying Wu,Jiayan Shi,Bingpu Zhou,Yanqing Tian

In this work, we presented a facile and cost-effective approach to fabricate novel PtTFPP/PDMS micro-pillar array (MPA) sensor film with I 0 /I 100 for gaseous oxygen and dissolved oxygen are 288 and 84, respectively. The sensitivity of the sensor film exhibited over ∼30-fold increment when compared with contemporary PtTFPP/PDMS-based oxygen sensors. The detection limit was as low as 0.10   μmol/L, which means that the ultrasensitive sensor films enable reliable monitoring of dissolved oxygen (DO) within nanomolar concentration ranges that are particularly difficult to achieve in previous works. Furthermore, the remarkably light intensity-changing characteristic of the sensing film under lower O 2 partial pressures facilitates convenient identification of O 2 concentrations even with the naked eye. We believe that the proposed device could be a promising candidate in various oxygen sensing fields such as nearly anoxic systems, unsteady pressure measurement and unsteady flow visualization, etc.

CAS / MDL: 9001-37-0
研究领域: 材料科学 · 传感技术 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
THIN SOLID FILMS · 2024 · IF 2

Enhanced light absorption in high-quality three-dimensional Sb2S3 micropillar arrays based on template-assisted growth

Tiebiao Qiu,Xin Jin,Lina Wang,Ting Lei,Guohao Bo,Jian Zhang

Sb 2 S 3 has garnered significant attention in photovoltaic applications due to its suitable bandgap, single stable orthogonal phase and excellent stability. However, due to the coexistence of indirect transition parts in the bandgap, a thicker Sb 2 S 3 absorption layer is usually required to achieve decent light absorption in solar cells, which inevitably leads to an increase in trapped states in the bulk. Therefore, it is of great importance to realize more photogenerated carriers without increasing charge recombination. Here, we realized the in-situ growth of high-quality Sb 2 S 3 micropillar arrays on the template prepared by laser direct writing. Compared with the traditional thick layer, this array structure with less material usage can not only achieve more light absorption by enhancing photon scattering, but also optimize carrier transport at the interface by expanding their contact area with the hole transporting layer. This work provides a strategy for controllably achieving enhanced light absorption of Sb 2 S 3 structures, which is a perspective for the improvement of highly efficient solar cells.

研究领域: 材料科学 · 光伏技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
RSC Advances · 2019 ·Vol. 9 ·期 45 ·26165-26171 · IF 3.049

Fabrication of a flexible transparent superomniphobic polydimethylsiloxane surface with a micropillar array

Shengyang Pan,Min Chen,Limin Wu

Although superomniphobic surfaces have attracted extensive interest owing to many important applications, successful fabrication of such surfaces still remains a critical challenge. Herein, we present a flexible transparent superomniphobic polydimethylsiloxane (PDMS) surface with a micropillar array using Si nanowires as the mould. The as-obtained PDMS not only exhibits excellent liquid-repellent performance with a static contact angle of over 150° and sliding angle of less than 6° against a wide range of liquids, but also maintains the super-repellency even under acid/base corrosion, mechanical damage, and unidirectional stretching.

研究领域: 材料科学 · 表面工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2022 · IF 16.744

Bioinspired micropillar array with micropit for robust and strong adhesion

Bo Zhu,Hao Cao,Zhouxiang Chen,Wentao Wang,Zhekun Shi,Kangjian Xiao,Yifeng Lei,Sheng Liu,Yi Song,Longjian Xue

Robust and strong adhesion is highly required for reversible adhesions. Inspired by gecko setae and octopus sucker, micropillar array with frustum of conical micropits (FCM) was fabricated by direct laser writing lithography. With an optimized micropit in FCM, the adhesion strength of 1.2 MPa is achieved under a loading force of 5 mN, which is 3.7 and 2.1 times the micropillars with flat punch top and circular conical micropit, respectively. Under a loading force larger than 3 mN, compliant contacts are formed between FCM micropillars and the counterpart surface, which results in a uniformly distributed stress at the separating interface, an instantaneous detachment of multiple FCM micropillars, and therefore a strong adhesion. Moreover, the adhesion of FCM is quite robust that 1000 cycles of attaching and detaching have no influence on the adhesion performance. The work here not only provides a bioinspired structure for strong and robust adhesion but also consolidates the concept of combining features from different biological systems to create new functional materials.

CAS / MDL: 78560-45-9
研究领域: 材料科学 · 仿生学 · 生物力学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2024 · IF 6.7

Extended-Gate FET Biosensor Based on GaN Micropillar Array and Polycrystalline Layer: Application to Hg2+ Detection in Human Urine

Jialing Zhou,Hui Huang,Qian Wang,Zhirui Li,Shunji Chen,Jun Yu,Yuan Zhong,Jing Chen,Huolin Huang

Owing to the separation of field-effect transistor (FET) devices from sensing environments, extended-gate FET (EGFET) biosensor features high stability and low cost. Herein, a highly sensitive EGFET biosensor based on a GaN micropillar array and polycrystalline layer (GMP) was fabricated, which was prepared by using simple one-step low-temperature MOCVD growth. In order to improve the sensitivity and detection limit of EGFET biosensor, the surface area and the electrical conductivity of extended-gate electrode can be increased by the micropillar array and the polycrystalline layer, respectively. The designed GMP-EGFET biosensor was modified with l-cysteine and applied for Hg2+ detection with a low limit of detection (LOD) of 1 ng/L, a high sensitivity of −16.3 mV/lg(μg/L) and a wide linear range (1 ng/L-24.5 μg/L). In addition, the detection of Hg2+ in human urine was realized with an LOD of 10 ng/L, which was more than 30 times lower than that of reported sensors. To our knowledge, it is the first time that GMP was used as extended-gate of EGFET biosensor.

CAS / MDL: 52-90-4
研究领域: 生物传感技术 · 材料科学 · 环境监测
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
CERAMICS INTERNATIONAL · 2025 · IF 5.6

Micropillar arrays supported mesoporous TiO2 photoanode for enhancing photoelectrochemical performance

Youxu Yu,Jinwang Li,Yuxin Liu,Zhefei Pan,Xun Zhu,Dingding Ye,Yang Yang,Hong Wang,Liang An,Rong Chen,Qiang Liao

Mesoporous TiO 2 photoanode shows promising application in photoelectrochemical systems due to large specific surface area and regular mesoporous structure. The evaporation-induced self-assembly method is usually employed for the preparation of mesoporous TiO 2 photoanodes. However, the photoelectrochemical performance of such a mesoporous TiO 2 photoanode prepared by this method is still unable to meet the demand owing to low photocatalyst loading, because the in-plane tensile stress during calcination may destroy the mesoporous TiO 2 film. To address this issue, the micropillar arrays supported mesoporous TiO 2 photoanode is proposed by directly synthesizing mesoporous TiO 2 film on the micropillar arrays loaded substrate. It is shown that the micropillar arrays interspersed inside the mesoporous TiO 2 film can help release the in-plane tensile stress during calcination, keeping the mesoporous structure intact. As a result, the photoelectrochemical cell with the optimized micropillar arrays supported mesoporous TiO 2 photoanode exhibits superior performance than does the nanoparticles-packed TiO 2 photoanode. Remarkably, the proposed method allows for preparing the TiO 2 micropillar arrays, by which the formed TiO 2 micropillar arrays supported mesoporous TiO 2 photoanode yields the optimal performance. As compared to the nanoparticles-packed TiO 2 photoanode, the short circuit current density and maximum power density increase by 63.6 % and 18.8 %, respectively.

研究领域: 材料科学 · 能源科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2017 ·Vol. 41 ·期 13 ·5429-5435 · IF 3.269

Platinum porphyrin/3-(trimethoxysily)propylmethacrylate functionalized flexible PDMS micropillar arrays as optical oxygen sensors

Yongyun Mao,Qian Zhao,Tingting Pan,Jiayan Shi,Shimei Jiang,Meiwan Chen,Bingpu Zhou,Yanqing Tian

Integrating an oxygen-sensitive probe (OSP) onto a three-dimensional (3D) microstructure substrate is a plausible technique to significantly improve the sensitivity of oxygen sensors. Despite the fact that polydimethylsiloxane (PDMS) matrices are regarded as the ideal sensory support, there are still no reports on an OSP functionalized flexible PDMS-based micropillar array (PDMS-MPAs) film as an optical oxygen sensor with capabilities to efficiently improve the sensor's overall performance, e.g. sensitivity, detection limit and stability against photo-bleaching. Herein, we reported the covalent bonding of a functional copolymer of platinum porphyrin (PtTPP)/3-(trimethoxysily)propylmethacrylate (PtTPP/TPMA) as the OSP on the surface of hydroxyl-modified PDMS-MPAs through a “grafting reaction” between PtTPP/TPMA and PDMS-MPAs. The homogeneous dispersion and well-isolated arrangement of the PtTPP/TPMA OSP on the 3D PDMS-MPA surface can ensure that the grafted OSP efficiently quenches the oxygen molecules. Consequently, the 3D PtTPP/TPMA-PDMS-MPA sensor film gives rise to a high fluorescence quenching efficiency of about 95% at 1 atm O2 (I0/I100 = 23) and 96% in aqueous solution (I0/IO2satu = 16) with an excellent linear Stern–Volmer plot (ksv = 0.1 h Pa−1, R2 = 0.997 in gas atmosphere and ksv = 12.8 mmol−1 L, R2 = 0.999 in aqueous solution, respectively), excellent reversibility and an ultra-low detection limit (4.7 μmol L−1) when compared with state-of-the-art PDMS-based oxygen sensors. Apart from the competitive sensitivity, the highly durable, reusable superiorities of the 3D PtTPP/TPMA-PDMS-MPA film can further facilitate the exploration and realization of the presented strategy for future oxygen sensor applications, such as the characterization of nearly anoxic systems in harsh environments.

CAS / MDL: 9001-37-0
研究领域: 材料科学 · 生物医学工程 · 化学传感
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SENSORS · 2024 ·Vol. 24 ·期 5 ·1603 · IF 3.4

CTAB-Modulated Electroplating of Copper Micropillar Arrays for Non-Enzymatic Glucose Sensing with Improved Sensitivity

Wenhao Yao,Hu He,Fuliang Wang

Micropillar array electrodes represent a promising avenue for enhancing detection sensitivity and response current. However, existing methods for depositing electrode materials on micropillar arrays often result in uneven distribution, with the thin sidewall layer being less conductive and prone to corrosion. In addressing this issue, this study introduces electroplating to enhance the copper layer on the sidewall of micropillar array electrodes. These electrodes, fabricated through standard microelectronics processes and electroplating, are proposed for non-enzymatic glucose detection, with the copper layer deposited via electroplating significantly enhancing sensitivity. Initially, the impact of cetyltrimethylammonium bromide (CTAB) concentration as an inhibitor on the surface morphology and sensitivity of the plated layer was investigated. It was discovered that CTAB could decrease surface roughness, hinder the development of large and coarse grains, generate small particles, and boost sensitivity. Compared to the uncoated electrode and plating without CTAB, sensitivity was elevated by a factor of 1.66 and 1.62, respectively. Subsequently, the alterations in plating morphology and detection performance within a range of 0.3 ASD to 3 ASD were examined. Sensitivity demonstrated a tendency to increase initially and then decrease. The electrode plated at 0.75 ASD achieved a maximum sensitivity of 3314 μA·mM−1·cm−2and a detection limit of 15.9 μM. Furthermore, a potential mechanism explaining the impact of different morphology on detection performance due to CTAB and current density was discussed. It was believed that the presented effective strategy to enhance the sensitivity of micropillar array electrodes for glucose detection would promote the related biomedical detection applications.

CAS / MDL: 7660-25-5
研究领域: 电化学 · 生物传感器 · 材料科学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2024 · IF 4.9

Fabrication of reusable SERS substrate based on pillar-assisted organogel

Yalei Wang,Chunning Chen,Jiaqi Liu,Jiaxin Lu,Jingtong Zhai,Hongkun Zhao,Rui Li,Nan Lu

To simultaneously possess the capability of reusability and non-destructive enrichment is very important for the SERS substrate in practical applications, but it is difficult to achieve the two capabilities simultaneously. In this work, an ordered micro-pillars array was prepared on the surface of organogel, analytes can be rapidly concentrated and enriched on the lubricating surface of the substrate, effectively avoiding the influence of “coffee ring” effect. At the same time, the pillar structures can effectively prevent the surface lubricating layer on substrate from being rapidly consumed, and it can be successfully used as a reusable supporting substrate in SERS detection, with the LOD of 5.1 × 10 −12 M and 1.1 × 10 −11 M for rhodamine 6G and crystal violet molecules.

CAS / MDL: 107-21-1
研究领域: 材料科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2022 · IF 10.383

Vertically Aligned Micropillar Arrays Coated with a Conductive Polymer for Advanced Pseudocapacitance Energy Storage

Yingying Zhang,Hui Zhang,Mingze Liu,Pengcheng Huo,Lei Feng,Yongze Ren,Jingkun Xu,Weiqiang Zhou,Ting Xu

With the development of high-performance supercapacitors, a conductive polymer (CP)-based pseudocapacitance electrode with good electrical conductivity and low processing costs holds a promising application prospect. As the core component of supercapacitors, the CP electrode with adjustable spacing, a high specific surface area, and a faster ion diffusion path has been extensively investigated. Herein, based on accurate top-down photolithography and electropolymerization approaches, we fabricate a CP-coated vertically aligned micropillar array (MPA) electrode. The electrode presents an overwhelming enhanced areal specific capacitance compared with that of a flat configuration, which is partially ascribed to an increased electroactive surface area, two rapid channels for ion diffusion and electron transfer, and enhanced electric field intensity that is provided by the MPA structure. Based on the fabricated CP-based MPA electrode, an asymmetric supercapacitor is assembled with two thiophene derivatives, presenting a high energy density and excellent cycling stability. A supercapacitor system cascading with three asymmetric supercapacitor devices further demonstrates the practical applications by driving the light-emitting diodes. This work provides a good reference for the further development of CP-based energy storage devices with high energy density and superior cycling stability.

研究领域: 材料科学 · 能源存储技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
LAB ON A CHIP · 2024 · IF 6.1

Integrated phase separation in microliter droplets for ultratrace-enriching biomarker analysis

Qihao Zha,Yong Luo,Conghui Liu,Tailin Xu

Ultratrace-enriching biomarker analysis is an effective method for achieving highly accurate and enhanced sensitive detection. In this study, we have developed an enrichment detection platform by combining a minipillar array with an aqueous two-phase system (ATPS) for ultratrace enriching biomarker analysis. After optimizing the enrichment conditions of ATPS, target miRNAs at ultratrace levels specifically accumulate in the DEX-rich phase, which significantly increases the target miRNA concentration-related fluorescence intensity. Compared to non-enriched miRNA in the single-phase PEG solution, the detection limit of ATPS-enriched miRNA had improved more than 200-fold. The ATPS-based enrichment detection strategy offers a novel and convenient approach for the simultaneous detection of biomarkers with ultratrace.

研究领域: 分析化学 · 生物技术 · 分子生物学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF MICROMECHANICS AND MICROENGINEERING · 2019 ·Vol. 29 ·期 10 ·105005 · IF 2.141

Miniaturized electrochemical sensor with micropillar array working electrode for trace lead online measurement in tap water

Xiangyi Hu,Hui Guo,Tong Qi,Weihua Fan,Chunping Jia,Baojian Xu,Qinghui Jin,Andreas Offenhäusser,Jianlong Zhao

A compact, durable, low-reagent-usage, portable miniaturized electrochemical sensor is successfully developed for the high sensitivity detection of trace lead. We fabricated micropillars array working electrodes on the chip and established ultra-low concentration sodium acetate-acetate (NaAC-HAC) buffers (pH  ≈  4.5) system to enhance the detection sensitivity of the sensor. The ultra-low concentration buffer possesses unique features such as low baseline current and high peak current difference height. The analytical performance of the fabricated electrochemical sensor with 3D gold (Au) working electrodes modified by bismuth-film was comprehensively studied. The microsensor exhibited a high sensitivity of 0.0412 µA ppb−1 and a satisfactory detection limit of 0.15 ppb when detecting lead ions under optimized conditions. Moreover, good linearity (correlation coefficient: 0.9993) with lead ion measurements in the concentration range of 1–120 ppb and excellent repeatability (RSD: 1.79%) was obtained, the chip has satisfactory selectivity for common interference ion. Besides, a low consumption of 350 µl of reagents per test was acquired. Finally, the proposed microsensor was applied to detect trace metal ions in tap and lake samples with satisfactory results.

研究领域: 环境科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。