文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
微通量门
BIOMEDICAL MICRODEVICES · 2013 ·Vol. 16 ·期 2 ·237-243 · IF 2.718

Investigation of targeted biomolecules in a micro-fluxgate-based bio-sensing system

Lei Jian,Lei Chong,Wang Tao,Yang Zhen,Zhou Yong

An investigation of targeted biomolecules was accomplished by combining a micro-fluxgate-based bio-sensing system and Dynabeads. The fluxgate sensor for biomolecule detection was fabricated by Micro Electro-Mechanical system technology, including thick photoresist lithography, electroplating and chemical wet etching. The magnetic core of the sensor was made of Fe-based amorphous ribbon core and three dimension solenoid coils were used as magnetic sensitive elements. The micro-fluxgate-based bio-sensing system was characterized firstly in different concentrations of Dynabeads, and a concentration as low as 100 ng/ml was detected with an external dc magnetic field in the range of 525 μT to 875 μT. Sandwich assays are performed using antibody-antigen pair combination of biotin-streptavidin on a separated Au film substrate surface with a self-assembled layer. Detection of Alpha Fetoprotein antigens with different concentrations was performed and a minimum detectable concentration of 1 pg/ml was achieved by the bio-sensing system. It is of considerable interest due to its potential application in the biomedical field based on known specific binding of target and labels.

CAS / MDL: 25952-53-8
研究领域: 生物医学工程 · 分子生物学 · 分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
APPLIED PHYSICS LETTERS · 2013 ·Vol. 103 ·期 20 · IF 3.794

Detection of targeted carcinoembryonic antigens using a micro-fluxgate-based biosensor

Lei Jian,Lei Chong,Wang Tao,Yang Zhen,Zhou Yong

In this work, a micro-fluxgate-based biosensor was designed for the detection of carcinoembryonic antigen (CEA) labeled by Dynabeads. The sensor with Fe-based amorphous core and three dimension solenoid coils was fabricated by Micro Electro-Mechanical system technology. Sandwich assays are performed using antibody-antigen pair combination of biotin-streptavidin assay on a separated Au film substrate surface with a self-assembled layer. With dc magnetic fields in the range of 560  μ T to 875  μ T, detection of CEAs with different concentrations was performed and a minimum detectable concentration of 1 pg/ml was achieved. Furthermore, CEA samples with different concentrations can be distinguished.

CAS / MDL: 25952-53-8
研究领域: 生物医学工程 · 诊断学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
RSC Advances · 2017 ·Vol. 7 ·期 82 ·52327-52336 · IF 3.108

Sensitive detection of cardiac troponin T based on superparamagnetic bead-labels using a flexible micro-fluxgate sensor

Lei Guo,Zhen Yang,Shaotao Zhi,Zhu Feng,Chong Lei,Yong Zhou

In this study, we describe an innovative micro-fluxgate immunosensor based on superparamagnetic Dynabeads for the detection of cardiac troponin T (cTnT), an important biomarker for cardiovascular diseases. The fluxgate sensor developed in this study uses a double layer of Co-based amorphous ribbons as a sensing element and three-dimensional solenoid copper coils to control the sensitive core. The system was fabricated through a standard micro-fabrication process, including thick photoresist lithography and electroplating. Superparamagnetic Dynabeads were employed as recognition tags and double polyclonal antibody pairs combined using streptavidin–biotin binding were employed to specifically capture and label the cTnT coupled with magnetic beads on a separate Au film-coated wafer via a classical sandwich immunoassay process. Series optimization of the assay parameters was performed to achieve optimal detection parameters. Under optimal conditions, the detection and quantification of cTnT was performed by sensing the magnetic signal of the cTnT-labeled Dynabeads with the micro-fluxgate sensor. The resulting biosystem successfully detected cTnT with satisfactory sensitivity, reproducibility, stability, and specificity. A minimum detectable limit of 0.01 ng mL−1 was achieved with a linearity range of 0.01–10 ng mL−1, demonstrating the high sensitivity of this novel system. In addition to the superior detection performance, the proposed sensor is convenient to manipulate, entirely lab-free, provides a quick result, and is portable. These factors suggest that this system has the potential to be applied as a point-of-care diagnostic tool for cardiovascular disease.

CAS / MDL: 25952-53-8 71310-21-9
研究领域: 医学诊断 · 生物传感器 · 纳米技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。