文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

5 项

设置提升方向
快速提取
JOURNAL OF CHROMATOGRAPHY A · 2016 · IF 3.926

Preparation of photonic-magnetic responsive molecularly imprinted microspheres and their application to fast and selective extraction of 17β-estradiol

Hailong Peng,Mei Luo,Hua Xiong,Ningxiang Yu,Fangjian Ning,Jieping Fan,Zheling Zeng,Jinhua Li,Lingxin Chen

Photonic-magnetic responsive molecularly imprinted microspheres (PM-MIMs) were prepared by seed polymerization, through suitable functionalization of magnetic nanoparticles for further coating with photoresponsive functional monomer and imprinted layers, and then were successfully applied to the fast and selective extraction of 17β-estradiol (17β-E 2 ) from real samples. The PM-MIMs possessed a sandwich micro-spherical structure containing Fe 3 O 4 core, SiO 2 middle layer, and MIPs shell with thickness of 25   nm. The PM-MIMs displayed excellent photoresponsive properties and could be rapidly separated from solutions under an external magnet. The PM-MIMs had specific affinity towards 17β-E 2 with high adsorption capacity ( Q max   =   0.84   mg   g −1 ) and fast binding kinetics ( K d   =   26.08   mg   L −1 ). The PM-MIMs proved to be an ideal photoswitch with the ability of reversible uptake and release of 17β-E 2 upon alternate 365 and 440   nm irradiation: 45.0% of 17β-E 2 released from the PM-MIMs upon 365   nm irradiation, and 94.0% of the released 17β-E 2 was rebound to the PM-MIMs at 440   nm. Accordingly, the PM-MIMs were applied for fast separation and extraction of 17β-E 2 followed by HPLC-UV determination, presenting the low limit of detection (LOD, S/N   =   3) and quantification (LOQ, S/N   =   10) of 0.18 and 0.62   μmol   L −1 , respectively. The high recoveries for spiked milk powder and drinking water samples were in the range of 97.5–113.0% with relative standard deviations less than 4.4%. This study reasonably combined photonic response, magnetic separation and surface imprinting, which endowed the PM-MIMs with significant advantages of high adsorption capacity and fast binding kinetics, convenient separation and recycled use, and simple rapid eco-benign adsorption/elution processes for template molecules. Thus, the PM-MIMs based method may be a simple, rapid, convenient, cost-effective and environmentally-friendly way for simultaneous separation, enrichment and detection of trace 17β-E 2 in complicated matrices.

研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF SEPARATION SCIENCE · 2022 ·Vol. 45 ·期 14 ·2687-2698 · IF 3.614

Magnetic phenolic resin core-shell structure derived carbon microspheres for ultrafast magnetic solid-phase extraction of triazine herbicides

Hong Pan,Zushan Gan,Haoyun Hu,Cheng Liu,Yipeng Huang,Guihua Ruan

In this study, monodisperse magnetic carbon microspheres were successfully synthesized through the carbonization of phenolic resin encapsulated Fe 3 O 4 core-shell structures. The magnetic carbon microspheres showed high performance in ultrafast extraction and separation of trace triazine herbicides from environmental water samples. Under optimized conditions, both the adsorption and desorption processes could be achieved in 2 min, and the maximum adsorption capacity for simazine and prometryn were 387.6 and 448.5 μg/g. Coupled with high-performance liquid chromatography-ultraviolet detection technology, the detection limit of triazine herbicides was in the range of 0.30–0.41 ng/mL. The mean recoveries ranged from 81.44 to 91.03% with relative standard deviations lower than 7.47%. The excellent magnetic solid-phase extraction performance indicates that magnetic carbon microspheres are promising candidate adsorbents for the fast analysis of environmental contaminants.

研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHROMATOGRAPHY A · 2022 · IF 4.601

Rapid and inexpensive nylon-66-filter solid-phase extraction followed by gas chromatography tandem mass spectrometry for analyzing perfluorinated carboxylic acids in milk

Mengyuan Li,Pengfei Li,Yehong Han,Dandan Han,Hongyuan Yan

In this study, a new rapid and inexpensive filter solid-phase extraction method (FSPE) was developed for the extraction and separation of five perfluorinated carboxylic acids (PFCAs) (namely, perfluorooctanoic acid, perfluorononanoic acid, perfluorodecanoic acid, perfluoroundecanoic acid, and perfluorododecanic acid) from milk samples. Commercial nylon 66 syringe filters were used as adsorbents without additional modification. The proposed method could achieve the fast adsorption of analytes by benefitting from the advantages of using the nylon 66 filter membrane on PFCAs with multiple adsorption interactions, namely, hydrophobic interactions and hydrogen bonds. The FSPE was designed to achieve the rapid isolation of analytes based on the rapid solid-liquid separation while using the solid-phase extraction disk. PFCAs residues in milk were extracted by first flowing the samples through a nylon 66 syringe filter from top to bottom. Double contact desorption with methanol was then accomplished by pulling and pushing the syringe, followed by derivatization with acetyl chloride-methanol. Finally, the extracted PFCAs residues were monitored using gas chromatography-tandem mass spectrometry (GC-MS/MS) quantification. Under optimal conditions, the established method presented good linearity (correlation coefficient ≥ 0.9996), precision (relative standard deviation ≤ 13%), accuracy (81–105%), sensitivity (limits of quantification: 4–18 ng kg −1 ) and extraction performance (10 min).

CAS / MDL: 75-36-5 2058-94-8
研究领域: 分析化学 · 食品安全 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Applied Polymer Materials · 2023 · IF 5

Individual Human Hair Keratin Rapidly Extracted Through the Advanced Oxidation Process and Their Hemostatic and Wound Healing Evaluations

Jia Deng,Xiaojing Yuan,Lian Wang,Yanqi Sun,Hao He,Zhenyi Wu,Zibin Gao,Jingou Ji,Bochu Wang,Shilei Hao

Autogenous keratin is a promising material for personalized wound healing applications. However, the common keratin extraction methods are time-consuming, and the variations in performance between different individual keratins are not clear. Herein, we developed TiO2 photocatalytic-assisted H2O2 oxidation strategy (H2O2/TiO2/UV), an advanced oxidation method, to rapidly extract human hair keratins within 2 h. The H2O2/TiO2/UV method for keratin extraction showed a higher protein yield compared to the H2O2 method. Keratins obtained from the developed method exhibited typical chemical and secondary structures. Furthermore, individual keratins from four young girls were extracted by using the H2O2/TiO2/UV method, and individual keratin/PCL films were successfully fabricated within 5 h. More importantly, individual keratin films displayed superior hemostatic performance and wound healing in vivo compared to that of keratin extracted via the H2O2 method. Interestingly, the four individual keratin films exhibited similar hemostatic efficiency but distinct wound-healing properties in terms of epidermal thickness and density of skin appendages. These data indicated that the developed H2O2/TiO2/UV method is an efficient and feasible approach to extract human hair keratins, which provides an intriguing possibility to explore personalized materials for promoting wound healing.

研究领域: 材料科学 · 生物医学工程 · 化学工程 · 组织工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2022 · IF 16.744

Plasmonic microneedle arrays for rapid extraction, SERS detection, and inactivation of bacteria

Yanbo Wang,Haojie Ni,Huan Li,Jian Chen,Dequan Zhang,Linglin Fu

Microbial contamination of food is a critical public health issue worldwide, making the rapid, efficient, and safe sensing strategies for foodborne microbes in urgent need. In this work, a plasmonic microneedle (MN) array patch was developed for rapid extraction and surface-enhanced Raman spectroscopy (SERS) detection of a model bacteria, Escherichia coli ( E. coli ). A hydrophilic MN matrix was firstly prepared by crosslinking [2-(methacryloyloxy)ethyl]trimethylammonium chloride (TMA), 2-carboxyethyl acrylate (CAA), and 2-hydroxyethyl methacrylate (HEMA) in a micro-mold. Then the obtained MN patch was treated with ozone and coated with SERS-active gold nanopopcorns (GNpops) that were modified with the specific aptamer towards E. coli . The resultant plasmonic MN patch could extract E. coli from agarose simulant in 3 min and was capable of on-MN SERS analysis with a detection limit of 143 CFU/g. The proposed detection method exhibited great specificity to E. coli and was feasible for evaluating the E. coli contamination of commercial mutton samples. Moreover, the extracted bacteria could be effectively inactivated through photothermal sterilization. The work opened a new avenue for simplifying the detection procedures for microorganisms and provided a potential approach for rapid and on-site microbial monitoring through the SERS-active MN patch.

研究领域: 生物医学工程 · 分析化学 · 食品安全 · 微生物学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。