文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
明胶酸
ACS Applied Materials & Interfaces · 2025 · IF 8.2

An Antibacterial, Antioxidant Adherent Sponge Constructed for Control of Arterial Bleeding Via Gallic Acid-Mediated Robust Assembly of Fibrous Clay in Collagen

Xin Guo,Xingling Zeng,Yeqing He,Xiaoxia Zhang,Wenli Shi,Ruimin Ran,Guoying Li

Acute hemorrhage death on battlefields, during clinical surgeries, and in major accidents is a widespread worldwide problem. Clay-based hemostatic materials have received considerable attention for their low cost and reliable clotting activity, especially in cases of severe bleeding, such as QuikClot, which is a kaolin-based hemostatic gauze that is preferred for battlefield resuscitation. However, the easy detachment of clay particles and the associated risk of thrombosis have seriously hindered the development of clay-based hemostatic materials. Here, inexpensive palygorskite (Pal) nanoclay was integrated into the collagen (COL) matrix by loading Ca2+ in the clay and further using gallic acid (GA) to mediate the robust assembly of clay on the COL matrix. This targeted interfacial design is a simple and gentle method that effectively improves the dispersion of the Pal particles and reduces the risk of shedding. Unlike QuikClot where the aqueous solution was significantly turbid after 2 min of ultrasonic washing, the aqueous solution of the composite sponge (Ca-Pal-GA-COL) remained clear and was accompanied by 82.71% of the mass residue after 10 min of ultrasonic washing. The composite sponge also exhibited excellent antibacterial (87.93% inhibition rate of Escherichia coli), antioxidant, and tissue adhesion properties. Importantly, the Ca-Pal-GA-COL sponge exhibited less blood loss (632 mg) and a shorter hemostasis time (151 s) in a rat femoral artery hemorrhage model than the medical gauze (3850 mg and 299 s), pure COL sponge (1627 mg and 201 s), and Pal-COL sponge (1494 mg and 193 s) in a co-mingled mode, which are comparable to those of QuikClot (559 mg and 142 s). Furthermore, certain tissue adhesion properties render the Ca-Pal-GA-COL sponge more suitable than QuikClot for severe femoral artery active bleeding scenarios. Cellular experiments confirmed that the composite dressing has a certain biosafety.

研究领域: 生物材料 · 医学工程 · 创伤修复
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。