It remains challenging to build up a multifunctional coating onto biodegradable magnesium (Mg) for biomedical use. In this study, a small amount of titanium dioxide (TiO 2 ) has been incorporated in situ into phytic acid (PA) coating when it was chemically deposited on Mg substrate targeted to biodegradable implant applications. Ultraviolet (UV) irradiation was utilized in the liquid phase deposition of TiO 2 to improve the quality of coating (PA&TiO 2 -UV). This PA&TiO 2 -UV coating was compact, thicker and more hydrophilic compared with sole PA or TiO 2 coating. The PA&TiO 2 -UV coated Mg presented a seven times lower electrochemical corrosion current density as well as significantly slower in vitro degradation rate up to 500 h in phosphate buffer saline as compared to the direct PA coated Mg. In addition, the UV irradiation showed remarkably to promote the MC3T3-E1 pre-osteoblast cells adhesion and proliferation especially after 7 days of culture. Further, the PA&TiO 2 -UV coating adhered more firmly on Mg substrate after 90° bending than the other coatings, indicating a better mechanical compliance on Mg substrate. These results make this PA&TiO 2 -UV complex coating bodes well for biodegradation slowing-down, osteo-compatible as well as mechanical compliant modification of Mg for orthopedic implants applications.
The controlling of heat flow direction stands as a prominent methodological approach within the domain of thermal management, and this can be accomplished through the utilization of thermal diodes. However, if the thermal diode lacks mechanical compliance, hindering its intimate contact with heat source/sink surfaces, the thermal rectification performance is limited. In this work, we propose a method to solve the mechanical compliance problem that is introducing phase change material (PCM) consisting of dual alkanes (hexadecane and paraffine wax) and polyurethane to fabricate the heterojunction thermal diode. The fabricated thermal diode exhibits an ultra-soft mechanical feature, with a low elastic modulus of 0.4 KPa and >300 % elongation until failure – the best values reported to date for thermal diodes. The measured thermal rectification factor is as high as 1.42 – in line with the theoretical model prediction. Molecular dynamic simulations reveal that the thermal rectification mechanism of the PCM-based thermal diode originates from the crystal-amorphous phase transition of the hexadecane terminal as the temperature bias flips. Therefore, the heat flow in the forward direction is greater than the flux in the reverse direction. A series of experiments and finite element analyses are employed to verify the feasibility of thermal diodes for applications in real contexts like the civil engineering.
Meng-Ting Xu,Yu Zhu,Chang Wei,Lei Liu,Zicai Zhu,Zhen-Hua Tang,Yuan-Qing Li,Shao-Yun Fu
Electrodes with high electrical conductivity, yet good flexibility and mechanical compliance, are critical for electroactive artificial muscles. Herein, a promising liquid metal (LM) electrode is proposed by transforming eutectic gallium–indium (EGaIn) LM with high surface tension into paste-like LM with solid Ga2O3 shells. The developed compliant LM electrode not only shows high conductivity and negligible additional stiffness but also displays excellent electrical stability during cyclic actuation. Based on the LM electrode, the poly(vinyl chloride) gel (PVCG) artificial muscle developed exhibits the maximum actuation strain of 18.7% at a low electric field strength of 9 V μm–1 and maintains excellent durability without obvious performance attenuation after 10,000 s. A comparison shows that the as-developed PVCG artificial muscle is superior over that based on widely used carbon electrodes. Moreover, an artificial upper limb and crawling worm were manufactured to explore the great potential of PVCG artificial muscle in the robotic field. In addition, the practical application demonstration of the PVCG artificial muscle in the biomimetics field is also successfully fulfilled through the design of reasonable structures. Due to its easy fabrication, excellent electrical conductivity, and high mechanical compliance, the newly developed LM electrode is promising for high-performance PVCG artificial muscles in bionic robots.