文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
板式CLIA
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY · 2024 ·Vol. 108 ·期 1 ·1-12 · IF 3.9

Development of plate-type and tubular chemiluminescence immunoassay against African swine fever virus p72

Miao Chun,Shao Junjun,Yang Sicheng,Wen Shenghui,Ma Yunyun,Gao Shandian,Chang Huiyun,Liu Wei

Abstract African swine fever (ASF) is a highly contagious and fatal viral disease that has caused huge economic losses to the pig and related industries worldwide. At present, rapid, accurate, and sensitive laboratory detection technologies are important means of preventing and controlling ASF. However, because attenuated strains of African swine fever virus (ASFV) are constantly emerging, an ASFV antibody could be used more effectively to investigate the virus and control the disease on pig farms. The isolation of ASFV-specific antibodies is also essential for the diagnosis of ASF. Therefore, in this study, we developed two chemiluminescence immunoassays (CLIAs) to detect antibodies directed against ASFV p72: a traditional plate-type blocking CLIA (p72-CLIA) and an automatic tubular competitive CLIA based on magnetic particles (p72-MPCLIA). We compared the diagnostic performance of these two methods to provide a feasible new method for the effective prevention and control of ASF and the purification of ASFV. The cut-off value, diagnostic sensitivity (Dsn), and diagnostic specificity (Dsp) of p72-CLIA were 40%, 100%, and 99.6%, respectively, in known background serum, whereas those of p72-MPCLIA were 36%, 100%, and 99.6%, respectively. Thus, both methods show good Dsn, Dsp, and repeatability. However, when analytical sensitivity was evaluated, p72-MPCLIA was more sensitive than p72-CLIA or a commercial enzyme-linked immunosorbent assay. More importantly, p72-MPCLIA reduced the detection time to 15 min and allowed fully automated detection. In summary, p72-MPCLIA showed superior diagnostic performance and offered a new tool for detecting ASFV infections in the future. Key points • Two chemiluminescence immunoassay (plate-type CLIA and tubular CLIA) methods based on p72 monoclonal antibody (mAb) were developed to detect ASFV antibody. • Both methods show good diagnostic performance (Dsn (100%), Dsp (99.6%), and good repeatability), and p72-MPCLIA detects antibodies against ASFV p72 with high efficiency in just 15 min.

CAS / MDL: 4432-31-9
研究领域: 兽医学 · 免疫学 · 分子生物学 · 诊断技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。