文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

3 项

设置提升方向
柔性传感器
MACROMOLECULAR RAPID COMMUNICATIONS · 2021 ·Vol. 42 ·期 22 ·2100457 · IF 5.734

Waterborne Polyurethane Enhanced, Adhesive, and Ionic Conductive Hydrogel for Multifunctional Sensors

Xiaobin Li,Ending Zhang,Jun Shi,Xiaoyan Xiong,Jiaming Lin,Qiang Zhang,Xiaohua Cui,Liqin Tan,Kun Wu

In the past two decades, ionic conductive hydrogel has attracted tremendous research interests for their intrinsic characteristics in the field of flexible sensor. However, synchronous achievement of high mechanical strength, satisfied ionic conductivity, and broad adhesion to various substrates is still a challenge. Herein, a novel zwitterionic composite hydrogel that displayed excited strechability (up to 900%), satisfied strength (about 30 kPa), high ionic conductivity (1.2 mS cm −1 ), and adhesion to polar and nonpolar materials is fabricated though the combination of waterborne polyurethanes (PU) and poly(sulfobetaine zwitterion- co -acrylamide) (SAm). Especially, this facile strategy demonstrates that PU has a synergistic effect on enhancing mechanical strength and ionic conductivity for ionic conductive hydrogel. Moreover, the hydrogel-based strain/stress sensor shows high sensitivity, wide sensing range, great stability, and accuracy for human body movements detecting and voice recognition. This novel ionic conductive hydrogel has promoted the development of wearable devices.

研究领域: 生物材料 · 高分子科学 · 柔性电子学 · 生物医学工程 · 传感器技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Journal of Healthcare Engineering · 2022 ·Vol. 2022 ·期 1 ·2271937 · IF 3.822

[Retracted] Real-Time Monitoring of Intraocular Pressure in Glaucoma Patients Using Wearable Mobile Medicine Devices

Xiangwen Yuan,Jiabin Zhang

Glaucoma is caused by excessive aqueous humor in the eye, resulting in a continuous or intermittent increase of intraocular pressure, which exceeds the tolerance of the eyeball and damages the optic nerve. Existing treatments for glaucoma do not work well or have significant side effects. Intraocular pressure signal is a very important physiological signal that needs real-time and accurate monitoring in glaucoma patients, especially in severe glaucoma patients. Therefore, long-term, real-time, and accurate monitoring of intraocular pressure is of great significance for the diagnosis and treatment of glaucoma patients. The use of wearable devices for real-time ocular diagnosis and treatment of glaucoma patients is an effective approach. However, the current commonly used intraocular pressure measurement and monitoring technology is difficult to meet the diagnosis and monitoring needs of glaucoma patients in terms of size, measurement accuracy, power consumption, and intelligence. Therefore, facing the needs of glaucoma disease treatment, this topic studies an implantable flexible intraocular pressure sensor for long-term continuous monitoring of intraocular pressure in glaucoma patients and mainly focuses on the working principle, structural design, process fabrication, measurement and control system, characterization, and performance test of the intraocular pressure sensor. It is of great significance for personalized and accurate treatment of glaucoma patients.

研究领域: 眼科 · 生物医学工程 · 传感器技术 · 转化医学 · 慢性病管理
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2023 · IF 15.1

Ionogel based triboelectric nanogenerator textiles for high-precision human fall recognition

Xiaodi Zhong,Tao Song,Haoran Dong,Saihua Jiang,Ruichao Wei

Currently, wearable sensors have been widely used for human behavior monitoring. Among them, triboelectric nanogenerator (TENG) textile has the functions of power generation and active sensing, showing great advantages in energy collection and signal transmission. However, the TENG textiles face problems such as limited recognition accuracy, insufficient flexibility, missed fashion sense, and complex manufacturing processes. To address the above issues, a core–shell structure integrated conductive fiber (C-fiber) based on ionogel and a hollow silicone tube are displayed. Owing to the fact that the C-fiber can be synthesized through a simple one-step UV curing process, it has the potential for large-scale production. Due to the dyeability of ionogel and the transparency of hollow tube, the C-fiber has the ability to obtain personalized colors. This fiber can be further woven into a flexible fabric sensor (W-TENG) for high-precision human behavior monitoring. Noteworthiness, the W-TENG still has flexibility and output signal in environments ranging from −18 to 200 °C,the strong wide temperature adaptability stem from the heat and frost resistance of the materials. By assembling W-TENG onto the human body, daily movements, fall types, and post fall states can be perceived. Furthermore, complex motion data is trained by support vector machine (SVM), and the recognition accuracy for different fall categories can reach 100%. In practical applications, TENG could be equipped with custom bluetooth modules to monitor falls in real-time during walking, and provide timely treatment for the injured.

研究领域: 生物医学工程 · 柔性电子学 · 可穿戴传感器 · 人机交互 · 运动健康监测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。