文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
柱技术
JOURNAL OF CHROMATOGRAPHY A · 2019 · IF 3.858

Multi-particle frits for packed capillary columns in electrochromatographic use

Jiannan Sun,Shiwei Yang,Heyong Cheng,Yuanchao Wang,Jinhua Liu

Further development of capillary electrochromatography (CEC) is to some extent restricted by column technology. Packed capillary columns are most commonly used in CEC because of higher sample capacity and higher sensitivity than open tubular columns, and better reproducibility and uniformity than monolithic columns. Fritting is the core component for the fabrication of packed capillary columns. Therefore various fritting technologies attract continuous attention from analytical community. A convenient fritting method was developed in this study. In contrast to the reported single-particle fritting, this method applies a multi-particle fritting technology to hold stationary phase in capillary columns. Several large porous particles smaller than the column internal diameter were tapped in and immobilized in inlet and outlet of the packing material bed due to direct and indirect keystone effect. Except the smallest permeability by the sintered frit and the lowest breaking pressure by the single-particle frit, EOF mobility and peak dispersion of the multi-particle frit were at the same levels with the formers. In addition, all the three frits avoided bubble formation. It demonstrated that the multi-particle frits met the general requirements of permeability, mechanical resistance and efficiency for packing capillary microcolumns as well as the sintered frits and the single-particle frits. Thus, peak efficiency around 4.3 μm plate height (approximately 232,560 plates per meter) was obtained by multi-particle fritted capillary columns with electrokinetic packing, compared to 6.5 μm plate height by single-particle fritted columns with slurry pressure packing. In particular, the multi-particle fritting was simpler, faster, and more reproducible than the sintered fritting, and the multi-particle fritting was suitable to pack capillary columns of various capillary bore sizes owing to rich commercial resources of fritting particles of various diameters. Multi-particle fritted columns offered satisfactory run-to-run and column-to-column reproducibilities for retention factor, plate height and peak area (precisions of 4.1–9.3% for 10 replicated columns, and precisions of 0.9–3.1% for 30 replicated trials). They also had consistent CEC performance (differences of 1.1–3.9% between the first and 31 st day) during a lifetime more than one month. Application examples in packing capillary columns of 75 and 100 μm i.d. and CEC analysis of sixteen polycyclic aromatic hydrocarbons prove the diversity and reliability of the multi-particle fritting in column technology.

研究领域: 分析化学 · 分离科学 · 色谱技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。