文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

4 项

设置提升方向
核电厂
SURFACE & COATINGS TECHNOLOGY · 2021 · IF 4.158

Microstructure and flow accelerated corrosion resistance of Cr coatings electrodeposited in a trivalent chromium bath

Ying Wang,Yanhong Liu,Guangbin Li,Mingmin Zheng,Yusha Li,Anlei Zhang,Yingchun Zhang

In this study, Cr coatings were electrodeposited on carbon steel substrates by a trivalent Cr salt. The microstructure of the Cr coatings and their flow accelerated corrosion (FAC) resistance in simulated secondary circuit environments (10 MPa and 150 °C) of nuclear power plants were investigated. The results showed that the as-deposited coating was amorphous and crack-free. Annealing at 200 °C resulted in the decrease of Cr (OH) 3 and the increase of Cr and Cr 2 O 3 on the coating surface , which improved the corrosion resistance of the coating. The subsequent FAC test showed that the Cr coatings significantly improved the FAC resistance of the carbon steel substrate. The coating annealed at 200 °C exhibited better FAC resistance. The Cr-rich oxide film formed on the coatings was mainly Cr 2 O 3 , with a small amount of Cr and CrO 2 . Due to the galvanic effects caused by pinhole defects, abnormally grown annular deposits formed on the coating surface.

CAS / MDL: 10026-24-1
研究领域: 材料科学 · 腐蚀与防护
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Nano Materials · 2023 · IF 5.9

Combining Electrospinning and Hydrothermal Methods to Prepare Bi2S3@SiO2 Nanostructure-Based Membranes for Enhanced Capture Capacity of Off-Gas Iodine from a Nuclear Plant

Xiaoping Li,Xinpeng Wang,Lei Dong,Qing Zou,Chunlin He,Yanqiu Zhu,Toyohisa Fujita,Changzhong Liao,Cheng-Wei Kao,Ying-Rui Lu

As the main fission products of nuclear power plants, radioactive iodine isotopes are of great concern because of their great harm to public safety. In this work, a nanocomposite of bismuth sulfide coated with the electrospinning SiO2 nanofibers with a diameter of about 280 nm nanostructure-based membranes (Bi2S3@SiO2) was successfully prepared to dispose of gaseous iodine. Results showed that the adsorption capacity of Bi2S3@SiO2 for iodine can be up to 1180 mg g–1, which is higher than the commercial silver-exchanged zeolite (AgZ) and other bismuth-based adsorbents. Chemisorption is the major adsorption behavior of iodine capture. Thermogravimetric analysis results demonstrated that the Bi2S3@SiO2 nanocomposites were stable up to 300 °C before and after capturing iodine. X-ray diffraction results revealed that BiSI was initially formed and then transformed to BiI3. Scanning electron microscopy revealed that the sulfur element remains in the samples after interacting with iodine, and X-ray absorption near-edge spectra further confirmed that its oxidation states are a mixture of S0, S3+, and S6+. The oxidation states of bismuth and iodine are Bi3+ and I–, respectively, revealed by X-ray photoelectron spectroscopy. The reactions between Bi2S3@SiO2 nanocomposites and I2 vapor are as follows: I2 was reduced to be I– and the BiI3 crystalline phase is the final form; S2– in Bi2S3 was oxidized to higher valences (S0, S3+, and S6+), and amorphous phases are their final forms. The research results demonstrated that the nanostructure-based membranes prepared by this work would be a promising candidate nanomaterial for capturing iodine in the plant off-gas streams.

CAS / MDL: 57-09-0
研究领域: 材料科学 · 环境工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY · 2019 ·Vol. 323 ·期 1 ·213-222 · IF 1.186

Automated separation and analysis of krypton-85 from low-volume gaseous effluent of nuclear power plant

Huang Yan-Jun,Guo Gui-Yin,Chen Chao-Feng,Yang Li-Tao,Shang-Guan Zhi-Hong,Sha Xiang-Dong,Yao Jian-Lin,Hu Chen

Based on the requirements of the lower detection limit for the low-volume gaseous effluent, we have designed an automatic separation apparatus of krypton (Kr). The principle of the apparatus is based on both the adsorption and desorption mechanism in the traps with the activated carbon particles and gas chromatography with 5A molecular sieves. The separation efficiency and overall recovery rate could be maintained at about (90.4 ± 4.2)% and (24.3 ± 1.3)%. The 85 Kr could be radioassayed on a liquid scintillation counter following the automatic separation and loading into the cryogenic count vial. The detection limit based the low-volume of 3 L is about 9.5 Bq m −3 , and the expanded relative uncertainties are in the range of 13–18% for typical measurements.

研究领域: 环境科学 · 核技术应用
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHROMATOGRAPHY A · 2025 · IF 4

Simultaneous determination of cations in nuclear power plant water by conductometric ion chromatography equipped with fluorescence detector

Wen Huang,Xiaoting Li,Feifang Zhang,Yufeng Shen,Bingcheng Yang

This study presents a simultaneous determination method for common corrosion-mark cations (Li⁺, NH₄⁺, monoethanolamine, Zn²⁺, and Cd²⁺) in nuclear power plant water. The analysis employs conductometric ion chromatography combined with a custom-built liquid core waveguide capillary scale fluorescence detector. Monovalent cations (Li⁺, NH₄⁺, monoethanolamine) were detected conductometrically with detection limits of 56–108 nM, while divalent heavy metals (Zn²⁺, Cd²⁺) were specifically quantified through the fluorescence detector, achieving detection limits of 42 nM and 33 nM, respectively. The method demonstrates good analytical performance, as indicated by the spiked recoveries ranging from 88.50 % to 128.54 % and relative standard deviations between 0.10 % and 4.16 % for all target analytes.

研究领域: 分析化学 · 核能工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。