文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
比率SERS
JOURNAL OF HAZARDOUS MATERIALS · 2024 · IF 12.2

Ratiometric SERS quantification of SO2 vapor based on Au@Ag-Au with Raman reporter as internal standard

Yu Lu,Xiufang Mo,Geng Zhu,Yan Huang,Yingchao Wang,Zhenzhong Yang,Liqiong Gao,Guofang Shen,Yi Wang,Xiangwei Zhao

Practical gas sensing application requires sensors to quantify target analytes with high sensitivity and reproducibility. However, conventional surface enhanced Raman scattering (SERS) sensor lacks reproducibility and quantification arising from variations of "hot spot" distribution and measurement conditions. Here, a ratio-dependent SERS sensor was developed for quantitative label-free gas sensing. Au@Ag-Au nanoparticles (NPs) were filtered onto anodic aluminum oxide (AAO) forming Au@Ag-Au@AAO SERS substrate. 4-MBA was encapsulated in the gap of Au@Ag-Au and served as the internal standard (IS) to calibrate SERS signal fluctuation for improved quantification ability. Combined with headspace sampling method, SO 2 residue in traditional Chinese medicine (TCM) can be extracted and captured on the immediate vicinity of Au@Ag-Au surface. The intensity ratio I 613 cm −1 /I 1078 cm −1 showed excellent linearity within the range of 0.5 mg/kg-500 mg/kg, demonstrating superior quantification performance for SO 2 detection. Signals for concentration as low as 0.05 mg/kg of SO 2 could be effectively collected, much lower than the strictest limit 10 mg/kg in Chinese Pharmacopoeia. Combined with a handheld Raman spectrometer, handy and quantitative TCM quality evaluation in aspect of SO 2 residue was realized. This ratiometric SERS sensor functioned well in rapid on-site SO 2 quantification, exhibiting excellent sensitivity and simple operability.

CAS / MDL: 50-81-7 1074-36-8
研究领域: 分析化学 · 材料科学 · 环境科学 · 药学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
RSC Advances · 2023 ·Vol. 13 ·期 15 ·10135-10143 · IF 3.9

An accuracy improved ratiometric SERS sensor for rhodamine 6G in chili powder using a metal–organic framework support

Yangjie Chen,Juan Hao,Zhihang Yin,Qinghui Wang,Youting Zhou,Lingpu Jia,Huiming Li,Wenlong Liao,Kunping Liu

Internal standard molecule 4-mercaptobenzoic acid (4-MBA) embedded Au core-Ag shell nanorods (Au-MBA@Ag NRs) were prepared by a seed-mediated growth method, then loaded on octahedral MIL-88B-NH2 to obtain a novel ratiometric SERS substrate of Au-MBA@Ag NRs/PSS/MIL-88B-NH2 (AMAPM) for detecting rhodamine 6G (R6G) in chili powder. The porous structure and excellent adsorption ability of MIL-88B-NH2, allowed for increased loading of Au-MBA@Ag NRs, thereby shortening the distance between adsorbed R6G and the “hot spot” resulting from local surface plasmon resonance (LSPR) of Au-MBA@Ag NRs. Based on the SERS characteristic peak ratio of R6G to 4-MBA, the ratiometric SERS substrate displayed improved accuracy and excellent performance for R6G detection, with a wide linear range of 5–320 nM and a low detection limit of 2.29 nM as well as fine stability, reproducibility and specificity. The proposed ratiometric SERS substrate offered a simple, fast and sensitive sensing strategy for R6G detection in chili powder, which demonstrated potential applications in food safety and the analysis of trace analytes in complex matrices.

CAS / MDL: 57-09-0 989-38-8
研究领域: 分析化学 · 纳米技术 · 食品科学 · 光谱学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2021 · IF 7.514

Ti3C2Tx MXenes loaded with Au nanoparticle dimers as a surface-enhanced Raman scattering aptasensor for AFB1 detection

Zhihui Wu,Da-Wen Sun,Hongbin Pu,Qingyi Wei,Xuanran Lin

Mycotoxin B1 (AFB1) contamination in agricultural products pose a deadly   danger   to   animal and human health and its rapid and reliable detection is thus very important. Herein, a ratiometric surface-enhanced Raman scattering (SERS) aptasensor for AFB1 detection was developed, in which 1,2-bis(4-pyridyl) ethylene (BPE) was used to trigger the assembly of Au nanoparticle dimers (AuNP dimers) and form intensive SERS “hot spots”, and MXenes nanosheets could load aptamer-modified AuNP dimers due to the hydrogen bonding and the chelation between the phosphate groups of aptamers and the Ti ion of MXenes. With the presence of AFB1 preferentially binding to AFB1 aptamer, AuNP dimers were separated from MXenes nanosheets, leading to a decrease in SERS intensity. Regression analysis in the range from 0.001 to 100 ng·mL −1 showed the limit of detection (LOD) being 0.6 pg·mL −1 in standard solution, indicating that the great prospects of the AuNP dimers/MXenes SERS substrate for detecting AFB1.

研究领域: 分析化学 · 纳米技术 · 食品安全 · 毒理学
✓ 已验证 产品关联 DOI PubMed 高影响因子