文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
氟-19 MRI
ANALYTICAL CHEMISTRY · 2023 · IF 7.4

High-Sensitivity, Low-Field 19F-MRI Approach Using High Manganese Ferrite Concentrations

Yupeng Cao,Xiaohan Zhou,Xiaoli Liu,Mei Yang,Wentao Liu,Dong Han

Fluorine-19 (19F) MRI (19F-MRI) is a promising method for quantifying biomedical research and clinical applications without background interference. Nevertheless, dependency on high-field MRI systems limits the applicability of 19F-MRI. Low-field MRI systems are more common than high-field MRI systems. Hence, developing 19F-MRI at low-field MRI devices can promote the 19F-MRI translation in medical diagnosis. The detection sensitivity of fluorine agents is critical in 19F-MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables an improved detection sensitivity while requiring ultrashort echo time (UTE) imaging methods to reduce the negative spin–spin relaxation (T2) decay effect. However, conventional UTE sequences require hardware with high performance. Herein, we introduce the k-space scaling imaging (KSSI) MRI sequence that accomplishes sampling k-space with variable scales to implement hardware-friendly UTE 19F-MRI compatible with low-field MRI systems. We implemented experiments with swine bone, a perfluorooctyl bromide (PFOB) phantom, and one tumor-bearing mouse on two self-customized low-field MRI systems. The swine bone imaging validated the ultrashort TE of KSSI. Under high concentrations of manganese ferrite, a high signal-to-noise ratio was shown in the imaging of a fluorine atom concentration of 658 mM, which indicated high-sensitivity detection of KSSI. Moreover, the KSSI sequence exhibited a 7.1 times signal-to-noise ratio of spin echo sequence on the PFOB phantom imaging with a fluorine atom concentration of 3.29 M. Additionally, the various concentrations of the PFOB phantom imaging revealed quantifiable capacity. Finally, the 1H/19F imaging was implemented with KSSI on one tumor-bearing mouse. This method provides the potential for clinical translation of fluorine probes at low-field MRI systems.

CAS / MDL: 423-55-2 110-54-3
研究领域: 医学影像 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。