文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
氨污染
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH · 2023 · IF 4.2

Hydrophobic Membrane for Water Recovery from Humid Gas by Membrane Condenser: Effects of Membrane Properties on Recovered Water Quality

Yu Huang,Hongjun Hu,Lixun Zhang,Guoqing Yi,Songhong Yu,Zhaohui Wang,Zhaoliang Cui,Shuaifei Zhao

Two hydrophobic porous ethylene-chlorotrifluoroethylene (ECTFE) membranes quenched in water and air were fabricated by thermally induced phase separation and used for water recovery from ammonia-containing humid gas via vapor condensation. The ECTFE membranes were further hydrophobically modified to enhance their condensation performance. The condensate water quality of the modified membrane significantly improved. The mechanisms of the NH3 contamination in the condensate water were discussed. Surface hydrophobic modification slightly increased the flux and recovery stabilities of the membranes. However, the modification also increased the membrane surface roughness, which adversely affects the vapor condensation and droplet evolution on the membrane surface and reduced the recovered water quality. From the material perspective, desirable porous membranes for vapor condensation should have high surface hydrophobicity and smoothness and reasonably large pore sizes. The reasonably large pore sizes would promote noncondensable gaseous contaminants (e.g., ammonia) to go through the membrane, thereby improving the recovered water quality.

研究领域: 材料科学 · 环境工程 · 化学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Environmental Technology & Innovation · 2022 · IF 7.758

Formation of disinfection byproducts in an ammonia-polluted source water with UV/chlorine treatment followed by post-chlorination: A pilot-scale study

Xinran Zhang,Pengfei Ren,Jianhua Zhou,Junyi Li,Zhenxing Li,Ding Wang

This study investigated the formation of disinfection byproducts (DBPs) from a real ammonia-polluted source water treated by a pilot-scale ultraviolet (UV)/chlorine process with subsequent post-chlorination. The experimental results indicated that UV/chlorine treatment enhanced the formation of trihalomethanes (THMs), haloacetic acids (HAAs), and haloacetonitriles (HANs) in post-chlorination, compared to UV or chlorine applied alone under parallel experimental conditions. DBP formation was observed to depend on pH values, chlorine doses, and reaction times. THM formation was higher at pH 9.0 than pH 6.0, while HAAs and HANs were produced more readily at pH 6.0 rather than 9.0. A higher chlorine dose led to a higher amount of DBPs formed after the treatment of UV/chlorine followed by post-chlorination. The concentration of DBPs increased with the UV/chlorine treatment time increasing from 2 to 15 s and then presented a decrease trend with the reaction time prolonging to 30 s. In addition, changes in natural organic matter (NOM) properties were evaluated using three-dimensional fluorescence spectra and parallel factor analysis (PARAFAC) UV/chlorine treatment effectively destroyed humic-like and tyrosine-like components in waters with the maximum fluorescence intensity ( FI m a x max ) reduced by 51.4% and 64.6%, respectively, compared to the raw water sample. The decrease of fluorescence of waters exhibited a positive correlation with the formation of DBP-FP in UV/chlorine treatment. Overall, DBP formation from the ammonia-polluted source water caused by UV/chlorine treatment could be managed by carefully determining chlorine doses and contact times to be used in the UV/chlorine process.

研究领域: 环境科学 · 公共卫生
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。