文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
泡沫柱
ACS Omega · 2023 · IF 4.1

Preparation of a Multifunctional and Multipurpose Chitosan/Cyclodextrin/MIL-68(Al) Foam Column and Examining Its Adsorption Properties for Anionic and Cationic Dyes and Sulfonamides

Jing Wang,Yong Zhang,Fubin Liu,Ying Liu,Litao Wang,Guihua Gao

A multifunctional cylindrical hybrid foam column, referred to as the chitosan/cyclodextrin/MIL-68(Al) (CS/CD/MIL-68(Al)) foam column, was prepared for the first time. The prepared foam column could be used for the adsorption/removal of hydrophilic and hydrophobic contaminants by different forms. Here, it was placed in hydrophilic dye solutions to investigate the adsorption behavior of methylene blue and trypan blue. The adsorption process followed the pseudo-second-order kinetic model with R2 ranging from 0.9983 to 0.9998 for methylene blue and from 0.9993 to 1.0000 for trypan blue, and the adsorption process was consistent with the Langmuir isothermal model with R2 greater than 0.96. The RL values for methylene blue and trypan blue were 0.8871 and 0.5366, respectively, which were present between 0 and 1, indicating that the adsorption behaviors of the two dyes onto the CS/CD/MIL-68(Al) foam column were favorable. The maximum adsorption capacities (Qm) of methylene blue and trypan blue were 60.61 and 454.55 mg/g at 298 K, respectively. Also, the CS/CD/MIL-68(Al) foam column was spun into a syringe and used to adsorb trace hydrophobic sulfonamides from water in the form of filtration. The porous structure impeded the need for any external force and equipment, allowing the water sample to pass through the foam column smoothly. The conditions of the CS/CD/MIL-68(Al) foam column were optimized. The adsorption was carried out under the condition of pH = 4, the amount of the adsorbent was two foam columns, and no salt was added. It was found that the removal rate of the CS/CD/MIL-68(Al) foam column for six sulfonamides was 100%, and it could be reused at least five times. Therefore, this CS/CD/MIL-68(Al) foam column had a simple preparation method, offered a flexible and diverse form of use, was nonpolluting, biodegradable, and reusable, and could have a wider application in the field of environmental pollutant removal and adsorption.

研究领域: 环境科学 · 材料科学 · 化学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF CHROMATOGRAPHY A · 2024 · IF 3.8

Preparation of cylindrical Chitosan/β-Cyclodextrin/MIL-68(Al) foam column for solid-phase extraction of sulfonamides in water, urine, and milk

Yong Zhang,Jing Wang,Fubin Liu,Litao Wang,Guihua Gao

This study describes the preparation of a cylindrical polymer foam column termed Chitosan/β-Cyclodextrin/MIL-68(Al) (CS/β-CD/MIL-68(Al)). An ice template-freeze drying technique was employed to prepare the CS/β-CD/MIL-68(Al) foam column by embedding MIL-68(Al) in a polymer matrix comprising cross-linked chitosan (CS) and β-cyclodextrin (β-CD). The cylindrical CS/β-CD/MIL-68(Al) foam was subsequently inserted into a syringe to develop a solid phase extraction (SPE) device. Without the requirement for an external force, the sample solution passed easily through the SPE column thanks to the porous structure of the CS/β-CD/MIL-68(Al) foam column. Moreover, the CS/β-CD/MIL-68(Al) foam column was thought to be a superior absorbent for SPE since it included the adsorptive benefits of CS, β-CD, and MIL-68(Al). The SPE was utilized in conjunction with high-performance liquid chromatography to analyze six sulfonamides found in milk, urine, and water. With matrix effects ranging from 80.49 % to 104.9 % with RSD values of 0.4–14.0 %, the method showed high recoveries ranging from 80.6 to 107.4 % for water samples, 93.4–105.2 % for urine, and 87.4–100.9 % for milk. It also demonstrated good linearity in the range of 10–258 ng·mL -1 with the limits of detection ranging from 1.88 to 2.58 ng·mL -1 . The cylindrical CS/β-CD/MIL-68(Al) foam column prepared in this work offered several advantages, including its simple fabrication, excellent water stability, absence of pollutants, biodegradability, and reusability. It is particularly well-suited for SPE. Furthermore, the developed SPE method, employing CS/β-CD/MIL-68(Al) foam column, is straightforward and precise, and its benefits, including affordability, ease of preparation, lack of specialized equipment, and solvent economy, underline its broad applicability for the pretreatment of aqueous samples.

研究领域: 分析化学 · 环境科学 · 食品科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。