Conventional methods for the detection of the sulfur mustard poisoning metabolic marker, thiodiglycol (TDG), require expensive instruments and reagents as well as professional operators. To address these problems, a novel test strip based on a molecularly imprinted sensitive membrane (MIM) was developed in this work for point-of-care (POC) detection of TDG. The TDG test strip was prepared conveniently by coating molecular imprinted polymers (MIPs) on a nitrocellulose membrane. When the sample contained TDG, the MIPs could specifically bind with TDG. A great number of AuNPs (AuNPs) could then be adsorbed on the test strip via the formation of an Au–S bond between TDG and AuNPs, giving the test strip the obvious red color of AuNPs. In the absence of TDG, the test strip exhibited much lighter color because it could not adsorb AuNPs. By monitoring the color change of the test strip, TDG could be detected from 1.0 ng/mL to 100.0 μg/mL with a detection limit of 0.23 ng/mL (3σ) under the optimal conditions (the molar ratio of TDG to MAA was 1:2; the eluent was chloroform; the elution time was 50 min; the reaction time between MIPs and TDG was 15 min; the adsorption time of AuNPs was 40 min; the temperature of the reaction system was 35 °C). This method has excellent selectivity and has been used to detect TDG in urine, showing great potential for POC detection of TDG in clinical samples.
Hong-mei Jiang,Ting Yang,Yan-hong Wang,Hong-zhen Lian,Xin Hu
A new approach of magnetic solid phase extraction (MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) has been developed for the speciation of Cr(III) and Cr(VI) using zincon-immobilized silica-coated magnetic Fe 3 O 4 nanoparticles (Zincon–Si–MNPs) as the MSPE absorbent. Cr(III) was quantitatively reserved on the absorbent at pH 9.1 while total Cr was reserved at pH 6.5. The absorbed Cr species were eluted by using 2 mol/L HCl and detected by GFAAS. The concentration of Cr(VI) could be calculated by subtracting Cr(III) from total Cr. All the parameters affecting the separation and extraction efficiency of Cr species such as pH, extraction time, concentration and volume of eluent , sample volume and influence of co-existing ions were systematically examined and the optimized conditions were established accordingly. The detection limit (LOD) of the method was 0.016 and 0.011 ng mL −1 for Cr(III) and Cr(VI), respectively, with the enrichment factor of 100 and 150. The precisions of this method (Relative standard deviation, RSD, n =7) for Cr(III) and Cr(VI) at 0.1 ng mL −1 were 6.0% and 6.2%, respectively. In order to validate the proposed method, a certified reference material of environmental water was analyzed, and the result of Cr speciation was in good agreement with the certified value. This MSPE–GFAAS method has been successfully applied for the speciation of Cr(III) and Cr(VI) in lake and tap waters with the recoveries of 88–109% for the spiked samples. Moreover, the MSPE separation mechanism of Cr(III) and Cr(VI) based on their adsorption–desorption on Zincon–Si–MNPs has been explained through various spectroscopic characterization.