文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
测试区
MICROCHIMICA ACTA · 2020 ·Vol. 187 ·期 7 ·1-8 · IF 6.232

Lateral flow immunostrips for the sensitive and rapid determination of 8-hydroxy-2′-deoxyguanosine using upconversion nanoparticles

Wu Nengying,Wei Yuxi,Pan Lanlan,Yang Xiaolin,Qi Honglan,Gao Qiang,Zhang Chengxiao

Lateral flow immunostrips were newly designed and a sensitive and rapid fluorometric method for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) as a model target of small biomarker molecules was developed. The upconversion nanoparticles (UCNPs, NaYF4:Yb/Er core, and polyacrylic acid (PAA)-modified shell, size ~ 39 nm, excitation wavelength = 980 nm; emission wavelength = 540 nm) were employed as fluorescence signal material. The 8-OHdG antibody (Ab) was taken as the recognition probe while UCNP-labeled Ab was taken as the signal probe. Bovine serum albumin (BSA) was designed as carrier protein for 8-OHdG to form 8-OHdG-BSA conjugate as the capture probe. The lateral flow immunostrips were prepared by laminating a sample pad (glass fiber membrane), a test pad (nitrocellulose membrane), and adsorption pad (filter paper) on PVP backing. The capture probe was immobilized on the test zone while an IgG antibody taken as the control probe was immobilized on the control zone. When the signal probe and the sample were in sequence loaded on the sample pad, 8-OHdG analyte bound with the signal probe, and then the excess of the signal probe move along the strip and is collected by the capture probe on the test zone while the remnant signal probe is collected by the control probe on the control zone. The signal probe and capture probe were synthesized and characterized. The fluorescence intensity on the test zone was inversely proportional to the concentration of 8-OHdG for the quantitative determination while the fluorescence emission on the control zone was observed to validate the assay. The developed method showed a wide linear range from 0.10 to 10 nM, a quite low detection limit of 0.05 nM, small sample volume requirement (100 μL), short assay time (15 min), and good method reproducibility (RSD = 4.4%, nine immunostrips). Schematic illustration of the configuration and measurement principle of lateral flow fluorescence immunostrip for 8-OHdG: (a) configuration; (b) preparation: load of capture probe (BSA-8-OHdG, 2 μL) on test zone; load of control probe (IgG Ab, 2 μL) on control zone; load of signal probe (UCNP-Ab, 16 μL) on sample pad; (c) measurement: load of sample (8-OHdG, 100 μL) on sample pad, collection, and measurement.

研究领域: 分析化学 · 纳米技术 · 生物医学工程 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。