文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
测量误差
Small Methods · 2019 ·Vol. 3 ·期 12 ·1900474 · IF 0

Is It Appropriate to Use the Nafion Membrane in Electrocatalytic N2 Reduction?

Yongwen Ren,Chang Yu,Xinyi Tan,Xiaotong Han,Hongling Huang,Huawei Huang,Jieshan Qiu

The electrocatalytic N 2 reduction reaction (ENRR) to ammonia has attracted much attention due to the mild operating conditions, in which the Nafion membrane is generally adopted to separate the ammonia from the anode products. However, it has been mentioned that the Nafion membrane allows ammonia to pass through and traps the ammonia to some extent, but powerful confirmation experiments and effective solutions are still lacking. Herein, it is experimentally confirmed that the use of the Nafion membrane in the ENRR is inappropriate, based on the results that the ammonia can pass through the membrane, be adsorbed on the membrane, and interact with the membrane. This causes a measurement error and accelerates the membrane degradation process, which is unfavorable for ammonia quantification and the long-term stability operation of the ENRR in practical application. Also, for the first time, a more accurate method to evaluate the activity of the ENRR electrocatalyst using a salt bridge to replace the Nafion membrane is presented.

研究领域: 化学工程 · 材料科学 · 电化学
✓ 已验证 产品关联 DOI
查看原文 查看 PubMed
POLYMER TESTING · 2013 · IF 1.646

Determination of ultra-low glass transition temperature via differential scanning calorimetry

Lidong Feng,Xinchao Bian,Gao Li,Zhiming Chen,Yi Cui,Xuesi Chen

A novel method was developed to determine the ultra-low glass transition temperature ( T g ) of materials through physical blending via differential scanning calorimetry . According to the Fox equation for polymer blends , a blend of two fully compatible polymers has only one T g . The single T g is a function of the T g s of the two simple polymers. Thus, the ultra-low T g of one material can be obtained from the T g s of another polymer and their blends. The error of T g measurements depends on the measurement error of the T g s for the blends and another polymer. The method was successfully applied to determine the T g s of acetyl tributyl citrate (ATBC), tributyl citrate (TBC) and poly(ethylene glycol)s (PEG)s with different molecular weights . The T g s for ATBC, TBC, PEG-4000 and PEG-800 were −57.0 °C, −62.7 °C, −76.6 °C and −83.1 °C, respectively. For all the samples, the standard deviation of measurements was less than 3.3 °C, and the absolute error of measurements was theoretically not more than 5.3 °C. These results indicate that this method has acceptable precision and accuracy.

CAS / MDL: 25322-68-3
研究领域: 材料科学 · 化学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Polymers · 2025 ·Vol. 17 ·期 17 ·2390 · IF 4.9

Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers

Guixiang Xie,Yaqi Lu,Xiaochun Lu,Zhusen Zhang,Shuidong Lin

Thermogravimetric analysis (TGA) has been extensively applied in polymeric characterization and quality inspection, facilitating in-depth investigations of the microstructural thermal response characteristics of polymers, including thermal stability, composition analysis, and thermal decomposition mechanisms. Here, the impacts of six factors on the TG thermal analysis curves obtained during operation are systematically examined while analyzing their causes and recommending solutions. Furthermore, the thermal degradation kinetics of an ionomer formed by neutralizing an ethylene–methacrylic acid copolymer with metal ions (SGP membrane) used in laminated tempered glass is analyzed using the Arrhenius equation, Ozawa–Flynn–Wall hypothesis and Kissinger method. Kinetic parameters at 5% degradation are fitted and used to predict the service lifetime of the SGP membrane. The results indicate that the SGP membrane sample exhibits activation energyEa= 136.90 kJ/mol, reaction ordern= 1.65 and pre-factorA= e25.93. It can be seen that the service lifetime of the SGP membrane sample is 16 years at 80 °C and 1.65 years at 100 °C.

CAS / MDL: 1310-73-2 79-10-7
研究领域: 高分子科学 · 热分析 · 材料化学 · 动力学建模
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。