文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

1 项目

设置提升方向
深共晶溶剂
ANALYTICA CHIMICA ACTA · 2019 · IF 5.256

Poly(deep eutectic solvent)-functionalized magnetic metal-organic framework composites coupled with solid-phase extraction for the selective separation of cationic dyes

Xiaoxiao Wei,Yuzhi Wang,Jing Chen,Panli Xu,Wei Xu,Rui Ni,Jiaojiao Meng,Yigang Zhou

Novel polymeric deep eutectic solvents (PDES) based on 3-acrylamidopropyl trimethylammonium chloride/D-sorbitol functionalized amino-magnetic (Fe 3 O 4 NH 2 ) metal-organic framework (HKUST-1-MOF) composites (Fe 3 O 4 NH 2 @HKUST-1@PDES) were synthesized and characterized by field emission transmission electron microscope (FE-SEM), transmission electron microscope (TEM), X-ray diffraction (XRD), fourier transform infrared spectrometry (FT-IR), thermal gravimetric analysis (TGA), vibrating sample magnetometer (VSM) and zeta potentials . Then the composites were firstly utilized to selectively separate malachite green (MG) and crystal violet (CV) coupled with magnetic solid-phase extraction (MSPE). A response surface methodology (RSM) based on Latin hypercube sampling (LHS) was selected to analytically optimize the extraction parameters including initial concentration of dyes, extraction time, pH value and extraction temperature. The maximum extraction amount and optimal extraction conditions predicted by the RSM model matched well with the actual experimental results, and the extraction amount was 966.93 mg g −1 for MG and 788.90 mg g −1 for CV,respectively. The results indicated that the model possessed higher calculation accuracy through analyzing fewer sample points, thereby achieving theoretical prediction of extraction amount and conditions and being a prefect supplementary to actual experiments. The electrostatic interaction between the composites and cationic dyes played the main roll in the extraction process. The proposed extraction method exhibited lower limit of detection (98.19 ng mL −1 for MG and 23.97 ng mL −1 for CV) and preeminent precision (RSD ˂ 0.4%). Spiked recoveries of fish samples at three spiking levers ranged from 89.43% to 100.65% for MG and 95.29%–98.03% for CV. All results highlighted the excellent potential of Fe 3 O 4 NH 2 @HKUST-1@PDES-MSPE strategy in selective separation of cationic dyes in complex medium.

CAS / MDL: 110-26-9 2783-94-0
研究领域: 分析化学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。