文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

1 项目

设置提升方向
溴异oval
International Journal of Electrochemical Science · 2023 · IF 1.5

Influence of Functional Monomer Glutathione on Core-shell Double Heterostructured Nanocage NiO/NiFe2O4@Zn0.76Co0.24S Performances as Electrochemical Sensor for Bromisoval Determination

Jiashuai Zhu,Lele Zhang,Kang Li

In this work, NiO/NiFe 2 O 4 @Zn 0.76 Co 0.24 S nanocages (NCs) with core-shell type double heterostructures were synthesized using a core-shell design scheme. Among them, NiO/NiFe 2 O 4 cubic cores were obtained by calcination of Ni-Fe Prussian blue analogs (PBAs), and Zn-Co-like zeolitic imidazole frameworks (ZIFs) growed in situ around these cubic cores and were sulfided to obtain NiO/NiFe 2 O 4 @Zn 0.76 Co 0.24 S NCs. The composite has a large specific surface area of 249.66 m 2 g -1 due to the inherited structure of the two bimetallic organic frameworks. And there is a core-shell double heterogeneous synergy between the Zn 0.76 Co 0.24 S NCs and p-p heterostructured NiO/NiFe 2 O 4 , which makes the modified electrode exhibit superior electrochemical performance for Bromisoval (BVU). In addition, glutathione (GSH) was explored to significantly enhance the electrochemical activity of BVU by nucleophilic substitution binding of its own -SH with -Br on BVU, which greatly improved the sensitivity. Then, GSH was developed as a new functional monomer, and beta-cyclodextrin (β-CD) was selected as a secondary functional monomer, and molecularly imprinted polymer (MIP) of BVU was prepared by CV electropolymerization to achieve a specific recognition of BVU. An electrochemical sensor based on NiO/NiFe 2 O 4 @Zn 0.76 Co 0.24 S NCs and MIP was constructed to detect BVU by DPV. Under the optimal conditions, the oxidation peak current of BVU was linear over the concentration range of 0.006-3.5 μM, with the limits of detection (LOD) and quantification (LOQ) of 0.28 nm and 0.933 nm, respectively. The sensitivity reached 11.0303 μA·μM -1 ·cm -2 . The method has a wider linear range and lower detection limits compared to other assays for BVU. And the sensor showed excellent reproducibility, repeatability and stability and had been applied to the determination of BVU in human serum and cosmetics with satisfactory results.

研究领域: 材料科学 · 分析化学 · 生物医学工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。