文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
犬瘟热病毒
Journal of Biophotonics · 2023 · IF 2.8

Trace detection of canine distemper virus based on Michelson-interferometer sensing probe

Xinyu Zhang,Xiangyu Hou,Wenlin Feng

A single-mode-fiber (SMF)-multimode-fiber (MMF)-tri-core-fiber (TCF) Michelson probe structure is proposed for trace detection of canine distemper virus (CDV). One end of the TCF is cut flat and fused with the multimode fiber, and the other end is coated with a silver film to enhance the reflection, and an optic-fiber sensing probe with SMF-MMF-TCF structure is obtained. The (PDDA/PSS) 3 multilayer film is modified on the surface of the fiber by layer-by-layer self-assembly method as a polyelectrolyte binder to immobilize CDV antibodies to form a (PDDA/PSS) 3 /CDV antibody composite membrane for specific detection of CDV antigens. The response-recovery test of the sensor is performed to verify its repeatability. The detection limit, the sensitivity, and the linear fitting degree for CDV antigen are 0.1236 pg/mL, 1.1776 dB/(pg/mL), and 0.9899, respectively. At the same time, the stability, selectivity, and clinical samples of the sensors were also verified.

CAS / MDL: 50-99-7 1310-58-3
研究领域: 光学传感 · 生物传感器 · 兽医学 · 纳米技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF PHYSICS D-APPLIED PHYSICS · 2023 ·Vol. 56 ·期 43 ·435401 · IF 3.4

Trace detection of canine distemper virus based on surface-functionalized optic-fiber Mach–Zehnder interferometer and the Vernier effect

Xinyu Zhang,Xiangyu Hou,Wenlin Feng

A surface-functionalized cascaded optic-fiber Mach–Zehnder interferometer (MZI) is proposed and fabricated for trace detection of canine distemper virus (CDV). The Vernier effect is formed based on single-mode fiber (SMF)-dislocation single-mode fiber-SMF. The two MZIs serve as the sensing arm and reference arm, respectively. The CDV antibody is modified on the sensing arm to detect CDV antigen, and the surface structure and morphology are analyzed by the atomic force microscope. The sensitivity of the cascaded MZI sensor is about 12 times than that of a single MZI. In the range of 0.1–104 pg ml−1 CDV, the detection limit of the cascaded MZI sensor is 0.1687 pg ml−1, and the response time is 25 min. The sensor also has good temperature, time stability and excellent selectivity. The biosensor has the advantages of low cost, easy preparation, high sensitivity and good selectivity, and has potential application for trace CDV detection.

研究领域: 光学传感 · 生物传感 · 病毒学 · 光学干涉
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。