RSC Advances
·
2014
·Vol. 4
·期 48
·25183-25188
·
IF 3.708
Meihua Wang,Weifen Niu,Xin Wu,Lixia Li,Jun Yang,Shaomin Shuang,Chuan Dong
3-Mercaptopropionic acid (MPA)-capped ZnS:Cu/ZnS core/shell quantum dots (QDs) have been synthesized via a facile aqueous coprecipitation method and characterized by fluorescence, UV-Vis absorption, infrared spectroscopy and transmission electron microscopy. The fluorescence of ZnS:Cu/ZnS could be increased in the presence of uric acid (UA). The affecting factors for the fluorescence of ZnS:Cu/ZnS were examined including pH, temperature and reacting time. Under the optimized conditions, the fluorescence intensity of the ZnS:Cu/ZnS QDs against the UA concentration showed a linear response in the range of 0.66 μM to 3.3 μM with the correlation coefficient (R2) 0.9973 and the limit of detection 0.044 μM. Most relevant molecules and physiological ions had no effect on the detection of UA. The feasibility of the developed method was further demonstrated by determining the concentration of uric acid in human urine samples and the recoveries were 95% ∼ 103%. Our work provides a sensitive, selective and convenient fluorescence method to determine UA in real samples.
研究领域:
分析化学
·
纳米医学
·
生物传感器
·
临床检验
·
分子诊断
✓ 已验证
DOI
高影响因子
CARBOHYDRATE POLYMERS
·
2019
·
IF 6.044
R.J. Wang,L.W. Zhang,R. Liu,L. Liu,J.M. Yao
Novel, portable, probe-free, liquid cellulose biosensor was explored via a facile one-pot process for Cu 2+ ions detection by naked eyes. The as-prepared biosensor displayed specific recognition towards Cu 2+ ions in aqueous solution, even in complex urine and serum samples within 10 s, showing fast response characteristic. There is barely any interference on the Cu 2+ ions detection by other metal ions or other complex substances in urine and serum, and the corresponding detection limit is as low as 1.185, 1.9309 and 1.9154 ppm, respectively. Moreover, the cellulose biosensor could act as an excellent candidate to sense Cu 2+ ions in biological samples including urine and serum from SD rats with satisfying accuracies and biocompatibility. This study exploits a potential application of cellulose in biosensing and monitoring related to Cu 2+ ions.
研究领域:
分析化学
·
生物传感
·
环境监测
·
临床诊断
·
材料科学
·
毒理学
✓ 已验证
DOI
高影响因子
BIOSENSORS & BIOELECTRONICS
·
2014
·
IF 6.451
Qin Xu,Lijuan Cai,Huijie Zhao,Jiaqian Tang,Yuanyuan Shen,Xiaoya Hu,Haibo Zeng
An enzymatic procedure based on a catalase biosensor for the detection of forchlorfenuron (CPPU) has been reported in this work. Catalase was immobilized on boron nitride (BN) sheets dispersed in chitosan by adsorption. The immobilized catalase exhibited direct electron transfer character and excellent electrocatalytic activity towards H 2 O 2 reduction. After introducing CPPU into the H 2 O 2 containing phosphate buffer solution , the catalase-catalyzed H 2 O 2 reduction current decreased. By measuring the current decrease, CPPU can be determined in the range of 0.5–10.0 µM with the detection limit of 0.07 μM. The non-competitive inhibition behavior of CPPU towards catalase was verified by the Lineweaver–Burk plots. Long stability character has been ascribed to this biosensor. Possible use of this biosensor in flow systems is illustrated. The proposed biosensor has been successfully applied to CPPU determination in fruits samples with satisfactory results.
研究领域:
分析化学
·
生物传感
·
食品安全
·
酶学
·
纳米材料
·
电化学
·
药物残留检测
✓ 已验证
DOI
高影响因子
Nanoscale
·
2018
·Vol. 11
·期 3
·962-967
·
IF 7.233
Zhaohong Su,Xiaolin Xu,Yongbing Cheng,Yueming Tan,Langtao Xiao,Daili Tang,Hongmei Jiang,Xiaoli Qin,Huixian Wang
A porous graphene (PG) bionanocomposite of PG, gold nanoparticles (AuNPs) and anti-indole-3-acetic acid (anti-IAA) antibody for sensitive and label-free amperometric immunoassay of IAA was reported. A PG film was produced by a pre-reduction/electrochemical reduction process on a glassy carbon electrode (GCE) and then a homogeneous AuNPs layer electrodeposition on the PG film. The anti-IAA antibody was immobilized onto the AuNPs through electrostatic adsorption and covalent conjugation. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, energy dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV), elecro-chemical impedance spectroscopy (EIS), ultraviolet visible spectroscopy (UV-vis) and differential pulse voltammetry (DPV) were used to characterize the PG film and the stepwise modification of the immunosensor. The electrochemical immunosensor exhibited a wide linear range from 2 × 10−11 to 2 × 10−8 g mL−1 with a detection limit of 0.016 ng mL−1 (S/N = 3) and showed significant linearity R2 = 0.9970. In addition, the proposed immunosensor showed acceptable selectivity and has been applied to the determination of IAA in the extract samples of several plant seeds with acceptable relative derivation (%) ranging from −5.25% to 4.24% between the immunosensor and high performance liquid chromatography. The proposed chemical pre-reduction and electro-reduction guided protocol can be extended to the preparation of many other functionalized PG nanocomposite films for wide applications.
研究领域:
生物传感
·
纳米生物技术
·
分析化学
·
植物生理学
·
电化学
·
免疫分析
✓ 已验证
DOI
高影响因子
MICROCHIMICA ACTA
·
2010
·Vol. 171
·期 3
·385-392
·
IF 2.648
Yin Huanshun,Zhou Yunlei,Liu Tao,Cui Lin,Ai Shiyun,Qiu Yanyan,Zhu Lusheng
An amperometric biosensor for nitrite was prepared by immobilizing cytochrome c (Cyt c) on a gold electrode that was modified with Nafion and a Cu-Mg-Al layered double hydroxide (Cu-LDH). The Cu-LDH was characterized by Fourier transform infrared spectroscopy and powder X-ray diffraction. The UV-visible spectrum suggests that Cyt c retains its native conformation in the modified film. The direct electrochemical investigation indicated that the composite film represents a good platform for the immobilization of Cyt c as well as an excellent promoter for the electron transfer between Cyt c and the gold electrode. Moreover, the biosensor showed a remarkable bioelectrocatalytic activity for the oxidation of nitrite with a linear range from 0.75 to 123 μM. The detection limit is 2 × 10 −7 M (S/ N = 3). The biosensor was successfully applied to the determination of nitrite in food samples.
研究领域:
生物分析化学
·
电化学传感
·
食品分析
·
生物传感器
·
分子诊断
✓ 已验证
DOI
高影响因子
BULLETIN OF THE KOREAN CHEMICAL SOCIETY
·
2018
·Vol. 39
·期 5
·657-664
·
IF 0.522
Nai-Di Tan,Jian-Hang Yin,Yaqing Yuan,Lei Meng,Na Xu
Herein, a novel bright-green and highly fluorescent polyethyleneimine capped copper nanoclusters (CuNCs@PEI) has been hydrothermally synthesized, which is employed as a fluorescence probe to determine rifampicin. Under optimum synthetic conditions, the morphology, surface chemistry and optical features of resulting CuNCs@PEI are well characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, UV–Vis absorption spectra, transient and steady-state fluorescence. In comparison to previous reports, the new species with a larger diameter of approximately 3 nm exhibit higher fluorescence quantum yield (QY) up to nearly 10.7%, and demonstrate tolerability to extreme pH, high ionic strengths as well as long-term UV irradiation. These excellent optical properties ascribe to unique grain size and surface chemical features of products, which are further discussed in this work. In addition, we employed as-prepared CuNCs@PEI to detect rifampicin based on fluorescence quenching phenomenon. The fluorescence intensity of probe is linearly proportional to rifampicin over the concentration rage from 0 to 20 μM, where the limit of detection (LOD) is 50 nM. Besides, this probe can be also used to assay rifampicin in serum samples with satisfactory recoveries.
研究领域:
分析化学
·
纳米生物技术
·
药物分析
·
分子诊断
·
转化医学
·
药代动力学
✓ 已验证
DOI
高影响因子
International Journal of Electrochemical Science
·
2023
·Vol. 12
·期 4
·3443-3458
·
IF 1.5
Shichao Xu,Yiyi Zhang,Kai Dong,Junnan Wen,Chunming Zheng,Shihuai Zhao
In this article, we present a simple and sensitive electrochemical DNA biosensor based on graphene oxide (GO)/chitosan (CS) hybrid nanocomposites modified glassy carbon electrode (GCE) for detection of Escherichia coli O157:H7 (E.coli O157:H7). The morphology and composition of GO and hybrid nanocomposites were characterized by transmission electron microscope (TEM), X-ray powder diffraction (XRD), field emission scanning electron microscopy (FESEM), and Fourier transform infrared spectrum (FTIR). Cyclic voltammetry investigations indicated that the GO/CS/GCE showed excellent electron transfer ability and good linear relation. Under the optimal hybridization conditions, electrochemical impedance spectroscopy (EIS) responses of ssDNA/GO/CS/GCE biosensor were in linear with the target DNA in the concentration range from 1×10 -14 to 1×10 -8 M with the detection limit as 3.584×10 -15 M (3σ). Moreover, differential pulse voltammetry (DPV) studies revealed good specificity and excellent ability of ssDNA/GO/CS/GCE biosensor to distinguish complementary, 1-base mismatched DNA, 2-base mismatched DNA and multi-base mismatched DNA. The developed strategy in this research revealed that the GO/CS modified electrode possess excellent performance for detecting of Escherichia coli O157:H7 DNA.
研究领域:
生物传感器
·
分子诊断
·
纳米医学
·
食品安全检测
·
微生物学
✓ 已验证
DOI
高影响因子
RSC Advances
·
2018
·Vol. 8
·期 66
·38003-38012
·
IF 2.936
Xiuqiong Chen,Huiqiong Yan,Wei Sun,Guangying Chen,Changjiang Yu,Wen Feng,Qiang Lin
To achieve the dispersion of the hydrophobic graphene (GR), the amphiphilic alginate caprylamide (ACA) was synthesized to fabricate electroactive Nafion/Mb–ACA–GR/CILE for the accurate determination of trichloroacetic acid (TCA). SEM observation, FT-IR and UV-Vis spectroscopic analysis indicated that ACA could tightly immobilize Mb and GR on the electrode surface by constructing biointerfaces, which not only provided Mb a suitable microenvironment to maintain its biological activity, but also shortened the distances between the active centers of Mb with carbon ionic liquid electrode (CILE), thus promoting the electron transfer rate. The electrochemical characterization of Nafion/Mb–ACA–GR/CILE showed that the direct electron transfer of Mb was realized on the modified electrode, which was attributed to the high electrical conductivity and excellent electrocatalytic activity of GR and good biocompatibility of ACA. Moreover, Nafion/Mb–ACA–GR/CILE exhibited good electrocatalytic activity towards TCA with the linear range from 2.5 to 47.3 mmol L−1 and lower KMapp value of 8.3 mmol L−1. Moreover, the modified electrode also revealed good stability, reproducibility and accurate detection of tap-water, exhibiting great potential for the applications as the third-generation electrochemical biosensors.
研究领域:
生物医学工程
·
电化学传感
·
纳米生物技术
·
分子生物学
·
分析化学
·
生物传感器
✓ 已验证
DOI
高影响因子
JOURNAL OF ELECTROANALYTICAL CHEMISTRY
·
2018
·
IF 3.235
Yang Yuan,Jiaxin Wang,Xinjiong Ni,Yuhua Cao
A biosensor for determination of 3-chloro-1, 2-propandiol (3-MCPD) was developed based on the electrochemically catalytic reduction by hemoglobin (Hb). Hb was concentrated and immobilized with magnetic molecularly imprinted nanoparticles (MMIPs NPs). The MMIP NPs had a core-shell structure, with magnetic Fe 3 O 4 NPs as the core and SiO 2 as the shell. MMIPs NPs were modified on the surface of a magnetic electrode to constitute the Hb enzyme-like sensor. The biosensor could catalyze the electrochemical reduction of 3-MCPD, and a direct electrochemical determination of 3-MCPD could be achieved for the first time. The biosensor, where Hb immobilized with MMIPs NPs had high electrochemical response for 3-MCPD, increased by 37.5% compared with Hb immobilized with magnetic non-imprinted nanoparticle (MNIPs NPs). The biosensor increased the response by 19.56% again under an external magnetic field . The reduction peak current had a linear relationship with 3-MCPD concentration ranging from 1.0 mg·L −1 to 160 mg·L −1 with a detection limit (S/N = 3) of 0.25 mg·L −1 . The biosensor was applied to the determination of 3-MCPD in soy sauce samples successfully with recoveries between 97.4% and 99.6%.
研究领域:
生物传感器
·
分析化学
·
食品科学
·
电化学
·
分子生物学
·
纳米医学
✓ 已验证
DOI
高影响因子
BIOSENSORS & BIOELECTRONICS
·
2011
·Vol. 30
·期 1
·112-117
·
IF 5.361
Huanshun Yin,Yunlei Zhou,Xiaomeng Meng,Kun Shang,Shiyun Ai
The graphene nanosheets and carbon nanospheres mixture (GNS–CNS) was prepared by electrolyzing graphite rob in KNO 3 solution under constant current, which was characterized by TEM, AFM, SEM, FT-IR, XRD, XPS, TGA and UV–vis. The nano-mixture can keep stable in water for more than one month. Based on this kind of mixture material, a novel electrochemical biosensing platform for glucose determination was developed. Cyclic voltammetry of glucose oxidase (GOD) immobilized on GNS–CNS/GCE exhibited a pair of well-defined quasi-reversible redox peaks at −0.488 V ( E pa ) and −0.509 V ( E pc ) by direct electron transfer between the protein and the electrode. The charge-transfer coefficient ( α ) was 0.51, the electron transfer rate constant was 2.64 s −1 and the surface coverage of HRP was 3.18 × 10 −10 mol cm −2 . The immobilized GOD could retain its bioactivity and catalyze the reduction of dissolved oxygen. The glucose biosensor has a linear range from 0.4 to 20 mM with detection limit of 0.1 mM. Moreover, the biosensor exhibits acceptable reproducibility and storage stability. The fabricated biosensor was further used to determine glucose in human plasma sample with the recoveries from 96.83% to 105.52%. Therefore, GOD/GNS–CNS/GCE could be promisingly applied to determine blood sugar concentration in the practical clinical analysis.
研究领域:
分析化学
·
纳米生物技术
·
电化学传感
·
生物医学工程
·
临床检验
✓ 已验证
DOI
高影响因子
ANALYTICAL BIOCHEMISTRY
·
2015
·
IF 2.219
Taotao Feng,Xiaoyu Chen,Xiuwen Qiao,Zhao Sun,Haining Wang,Yu Qi,Chenglin Hong
In this work, a simple electrochemical immunosensor was developed for the detection of carcinoembryonic antigen (CEA) based on rhombic dodecahedral Cu 2 O nanocrystals–graphene oxide–gold nanoparticles (rCu 2 O–GO–AuNPs). GO as the template and surfactant resulting in rCu 2 O exhibit improved rhombic dodecahedral structure uniformity and excellent electrochemical performance. Moreover, GO was found to be able to effectively improve the long stability of rCu 2 O on the electrode response . Under optimal conditions, the immunosensor showed a low limit of detection (0.004 ng ml −1 ) and a large linear range (0.01–120 ng ml −1 ). This work presents a potential alternative for the diagnostic applications of GO-supported special morphology materials in biomedicine and biosensors.
研究领域:
生物医学工程
·
肿瘤学
·
纳米医学
·
电化学分析
·
诊断学
·
生物传感器
✓ 已验证
DOI
高影响因子
Small
·
2022
·Vol. 18
·期 29
·2202622
·
IF 15.153
Hao Zhu,Zixuan Chen,Yun Chen,Jun-Jie Zhu
Quantifying the binding kinetics and affinities of protein–small molecule interactions is critical for biomarker validation, drug discovery, and deep understanding of various biological processes at the molecular-scale. Novel approaches are demanded as most common label-free techniques are mass-sensitive, which are not suitable for the detection of small molecule interactions. Here, an optical imaging platform is developed to measure the binding kinetics of both protein–small molecules and protein–ions based on monolayer MoS 2 , an ultra-thin 2D material whose optical absorption is extremely sensitive to charge. A model is established to calibrate the optical response due to the charged analyte binding and it is applied to quantify the interactions between abl1 kinase and different small-molecule inhibitors. Such a presented method is capable of distinguishing different inhibitors binding to a wild or mutated kinase, which provides guidance for drug evaluation and drug mechanism exploration. The binding kinetics of calcium ions to calmodulin is also measured, further broadening the application field of the method. In addition, the imaging capability allows mapping the local binding kinetics of the molecular interactions with a high resolution, which reveals visible spatial variability and offers a promising tool for studying heterogeneous local interfacial interactions.
研究领域:
分子生物学
·
药物发现
·
生物传感器
·
化学生物学
·
生物物理
·
转化医学
·
纳米生物技术
✓ 已验证
DOI
高影响因子